T14 Ex thermometer 100

T14 Ex thermometer 100
Ex thermometer 100
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust thermowells and special materials. A optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. Flexible configuration possible.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application Explosion Proof US style
modular temperature assembly
for heavy duty applications
flanged process connection
with extension
incl. thermowell
Thermowell / protection tube bar stock (drilled)
Insert / probe mineral insulated (MI), flexible
PTFE-insulated, rigid
Outer diameter protection tube / Insert 7/8'' (22,23 mm)
17/16'' (26,99 mm)
Max. immersion length on request up to 22.5" (571 mm)
others on request
Material protection tube/ thermowell 316/316L
others on request
Optional coating Available on request
Process connection flange:
ASME 1" 150 RF (B16.5)
ASME 1" 300 RF (B16.5)
ASME 1" 600 RF (B16.5)
ASME 1" 900/1500 RF (B16.5)
ASME 1,5" 150 RF (B16.5)
ASME 1,5" 300 RF (B16.5)
ASME 1,5" 600 RF (B16.5)
ASME 1,5" 900/1500 RF (B16.5)
ASME 2" 150 RF (B16.5)
ASME 2" 300 RF (B16.5)
ASME 2" 600 RF (B16.5)
ASME 2" 900/1500 RF (B16.5)
Tip shape straight
tapered
Surface roughness Ra 32 μin. (0.80 μm)
Operating temperature range PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static) at 20 °C: 500 bar (7.252 psi)
depends on configuration
Accuracy class A acc. to IEC 60751
class B acc. to IEC 60751
Response time depending on configuration
63% rt = 20 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals FM XP DIP
FM XP NI DIP
CSA XP DIP
CSA XP NI DIP
FM/CSA XP DIP
FM/CSA XP NI DIP
CSA C/US XP, DIP
cCSAus General Purpose
Certification SIL (transmitter only)

The robust thermometer can be used under demanding conditions and in safety applications, e.g. in the chemical, oil & gas and energy industries. The robust thermowell and special materials can meet the measurement requirements of harsh conditions, corrosive media and maximum pressures. Used with modular transmitters with all common communication methods, it can measure directly; compared with directly wired sensors, it offers higher measuring accuracy and reliability. It can be configured flexibly.

Advantages

  • FM/CSA XP Cl. I, Div. 1 certified thermometer with the highest safety

  • One-stop temperature measurement solution. First-class transmitter with integrated sensor for demanding industrial process applications.

  • Install and use directly after unpacking

  • Improved electrical isolation (2 kV) when installed on most devices

  • Simple modular structure: excellent value for money. Easy ordering and reordering. The complete unit with sensor, thermowell and transmitter provides a complete measuring point solution

  • Long-term stability of all iTEMP® transmitters ≤ 0.05 %/year

Application

  • T14 is a resistance thermometer (RTD) installed in a thermowell, certified by FM and CSA, and can be used under harsh conditions and in hazardous areas. The sensor consists of a measuring probe with insulated resistance (RTD) element, a mineral-insulated insert and a bar stock thermowell.

  • The sensor can be used in the following process industries, e.g.:

  • Chemical industry

  • Petrochemical industry

  • Refineries

  • Offshore platforms

Spare Parts & Accessories 52

52 spare parts · click to collapse
Order codeDescription
TU401-Enclosure TU401, US StyleProduct being phased out, limited availability.Enquire
TA30H-Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).Enquire
71600564O-ring 74x3 75° VMQ silicone rubberPacking unit: 5 piecesDetails
TMT162X-Spare part TMT162XEnquire
TMT162E-Electronic module TMT162EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire
TMT162G-Housing TMT162GEnquire
TMT162X-Spare part TMT162XEnquire
TMT162G-Housing TMT162GEnquire
TMT162X-Spare part TMT162XEnquire
TMT162E-Electronic module TMT162EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire
TMT162G-Housing TMT162GEnquire
TMT162X-Spare part TMT162XEnquire
TMT162X-Spare part TMT162XEnquire
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
71386275Integrable Surge Arrester ModuleFor subsequent mounting in field transmitter. Ensure compatibility.Details
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT142G-Housing TMT142GHousing TMT142GEnquire
TMT142E-Electronic module TMT142EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

All documents for this model
2 documents · click to expand
TI

T13, T14 and T15 English

Rev. 1623 24 pages
Preview
TI

RTD T13, T14, and T15 English

Rev. 1206 24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.