Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

T15 Ex RTD thermometer

T15 Ex RTD thermometer
Ex RTD thermometer
The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application Explosion Proof US style
modular temperature assembly
for heavy duty applications
with extension
to be used with existing thermowell
Thermowell / protection tube to be used with thermowell
Insert / probe mineral insulated (MI), flexible
PTFE-insulated, rigid
Outer diameter protection tube / Insert Not applicable
Max. immersion length on request up to 100" (2540 mm)
others on request
Material protection tube/ thermowell Sensor sheath
316/316L
Optional coating Not defined
Process connection male thread:
NPT1/2"
Tip shape straight
Surface roughness Ra Not defined
Operating temperature range PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static) Not applicable
Accuracy class A acc. to IEC 60751
class B acc. to IEC 60751
Response time 63% rt = 3 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals FM XP DIP
FM XP NI DIP
CSA XP DIP
CSA XP NI DIP
FM/CSA XP DIP
FM/CSA XP NI DIP
CSA C/US XP, DIP
cCSAus General Purpose
Certification SIL (transmitter only)

The robust thermometer consists of a protection tube and a connection head that can be fitted with different transmitter types to meet different application environments and space requirements. The thermometer offers high measuring accuracy and reliability and is available with various process connections, dimensions and materials (e.g. 316L SS and Hastelloy C276) for flexible use in a wide range of applications.

Advantages

  • FM/CSA XP Cl. I, Div. 1 certified thermometer with the highest safety

  • One-stop temperature measurement solution. First-class transmitter with integrated sensor for demanding industrial process applications.

  • Install and use directly after unpacking

  • Improved electrical isolation (2 kV) when installed on most devices

  • Simple modular structure: excellent value for money. Easy ordering and reordering. The complete unit with sensor, thermowell and transmitter provides a complete measuring point solution

  • Long-term stability of all iTEMP® transmitters ≤ 0.05 %/year

Application

  • T15 is a resistance thermometer (RTD) installed in a thermowell, certified by FM and CSA, and can be used under harsh conditions and in hazardous areas. The sensor consists of an insulated resistance (RTD) measuring probe and a mineral-insulated insert.

  • The sensor can be used in the following process industries, e.g.:

  • Chemical industry

  • Petrochemical industry

  • Refineries

  • Offshore platforms

Spare Parts & Accessories 16

16 spare parts · click to collapse
Order codeDescription
TMT31-F+ Temperature transmitter TMT312-wire temperature transmitter. Single sensor input. Application: RTD/TC. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC, presetting failure current low. Consider additional marine certificate requirements on application side.Enquire
TMT71-Temperature transmitter TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.Enquire
TMT72-Temperature transmitter TMT722-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oCEnquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
71044062equipment package2x screws, 1x sealing CDI-connectorDetails
TU111-General Purpose RTD Insert, TU111, U.S.Product being phased out, limited availability. Spare part. Spring loaded. General purpose. Pt100 sensor comply with IEC60751 standard, alpha=0.00385.Enquire
71660542Set Terminal Block 3-wire TS211Packing unit: 5 piecesDetails
71660543Set Terminal Block 4-wire TS211Packing unit: 5 piecesDetails
71660544Set Terminal Block 6-wire TS211Packing unit: 5 piecesDetails
TMT142E-Electronic module TMT142EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT162E-Electronic module TMT162EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire
TMT162X-Spare part TMT162XEnquire
T15-RTD T15Spring loaded temperature measuring devise, without thermowell. Hazardous approval. Pt100 Sensor comply with IEC60751 standard, alpha=0.00385.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

All documents for this model
2 documents · click to expand
TI

T13, T14 and T15 English

Rev. 1623 24 pages
Preview
TI

RTD T13, T14, and T15 English

Rev. 1206 24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.