The high modular thermometer is used for several applications with harsh environments, e.g. in Power Plants, Refineries or in the Chemical or Petrochemical industry. The robust device is designed for use within an existing thermowell. With different head transmitter it's a complete unit ready for use with enhanced measurement accuracy and reliability.
Compare

Thermometer

Measuring Principle Thermocouple
Characteristic / Application Explosion Proof US style
modular temperature assembly
for heavy duty applications
with extension
to be used with existing thermowell
Thermowell / protection tube to use with thermowell
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 1/4'' (6,35 mm)
3/8'' (9,53 mm)
Max. immersion length on request up to 100" (2540 mm)
others on request
Material protection tube/ thermowell Sensor sheath
316
Alloy 600
Optional coating not applicable
Process connection Thermowell connection
male thread:
NPT1/2"
Tip shape straight
Surface roughness Ra not applicable
Operating temperature range Type T:
-270 °C ...400 °C
(-454 °F ...752 °F)
Type J:
-210 °C ...1200 °C
(-346 °F ...2.192 °F)
Type E:
-270 °C ...1.000 °C
(-454 °F ...1.832 °F)
Type K:
-270 °C ...1.372 °C
(-454 °F ...2.500 °F)
Type N:
-270 °C ...1.300 °C
(-454 °F ...2.372 °F)
Max. process pressure (static) not applicable
Accuracy Standard acc. to ASTM E-230
Special acc. to ASTM E-230
Response time 63% rt = 1 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals FM XP
CSA XP
FM/CSA XP
CSA GP
Certification SIL (transmitter only)

The highly modular thermometer is suitable for many applications under harsh conditions, e.g. power plants, refineries, chemical or petrochemical industries. It is robust and designed for installation in existing thermowells. Combined with various modular transmitters it forms a complete measuring system with higher measuring accuracy and reliability.

Advantages

  • FM/CSA XP Cl. I, Div. 1 certified thermometer with the highest safety

  • One-stop temperature measurement solution. First-class transmitter with integrated sensor for demanding industrial process applications.

  • Install and use directly after unpacking

  • Improved electrical isolation (2 kV) when installed on most devices

  • Simple modular structure: excellent value for money. Easy ordering and reordering. The complete unit with sensor and transmitter provides a complete measuring point solution

  • Long-term stability of all iTEMP® transmitters ≤ 0.05 %/year

Application

  • The sensor can be used in the following process industries, e.g.:

  • Chemical industry

  • Petrochemical industry

  • Refineries

  • Offshore platforms

Spare Parts & Accessories 48

48 spare parts · click to collapse
Order codeDescription
51004454*** ConnectorDisplay fitting kit field housingDetails
71310423Display housing fixing kit (3 pcs)Details
71502617O-ring 88x3 HNBR 70° Shore PTFE_5pcsPacking unit: 5 piecesDetails
71600564O-ring 74x3 75° VMQ silicone rubberPacking unit: 5 piecesDetails
51004948front cover latch pinScrew, washer, spring washerDetails
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT162X-Spare part TMT162XEnquire
71044062equipment package2x screws, 1x sealing CDI-connectorDetails
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
51007995mounting bracketMounting bracket SS316L, tube 1,5-3"Details
TMT162X-Spare part TMT162XEnquire
TMT162X-Spare part TMT162XEnquire
TMT162A-TMT162A accessoriesProduct Phased Out.Enquire
TU221-TC insert, approved, TU221, U.S. StyleProduct being phased out, limited availability. Thermocouple insert spring loaded. Flame path nipple. Comply with EMF tables of ASTM E-230 and IEC60584, color codes per ASTM E-230.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

All documents for this model
2 documents · click to expand
TI

T53, T54 and T55 English

Rev. 1623 24 pages
Preview
TI

Thermocouple T53, T54, T55 English

Rev. 1206 24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermocouples — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.

Food & Beverage

Food & Beverage · thermocouples — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermocouples — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · thermocouples — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.