Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TAF12S

TAF12S
iTHERM FlameLine TAF12S
Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell made from ceramic materials serves as protection from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.
Compare

Thermometer

Measuring Principle Thermocouple
Characteristic / Application metric style
modular temperature assembly
high temperature (furnace)
incl. single ceramic thermowell
Thermowell / protection tube ceramic protection tube
Insert / probe ceramic capilarry, rigid
Outer diameter protection tube / Insert 9,0 mm (0,35'')
Max. immersion length on request up to 2.500,00 mm (98,43'')
Material protection tube/ thermowell Ceramic (C610/C799)
Process connection compression fitting:
G1/2"
G3/4"
G1"
adjustable Flange
Tip shape straight
Operating temperature range Type S:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type R:
0° C ...1.600 °C
(32 °F ...2.912 °F)
Type B:
600 °C ...1.700 °C
(1.112 °F ...3.092 °F)
Max. process pressure (static) at 20 °C: 1 bar (15 psi)
Accuracy class 2 acc. to IEC 60584
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Certification SIL (transmitter only)

Product Overview

Measuring points with extremely high process temperatures require thermometers fitted with ceramic thermowells and thermocouples made of special metals such as platinum and rhodium. The thermowell made of special material protects the measuring element during the process, prevents mechanical damage or chemical corrosion and extends the service life of the sensor. The result: reduced maintenance costs at the measuring point, improved product quality and enhanced production safety.

  • Benefits

  • Thermowell made of innovative material for higher durability and corrosion resistance, extending the service life

  • Sensor protected by non-porous material, ensuring long-term stable temperature measurement

  • Modular design for flexible product selection

  • Replaceable parts minimize life-cycle operating costs

Spare Parts & Accessories 17

17 spare parts · click to collapse
Order codeDescription
71389514Extension wire TC IEC 2x type S/RL=180mm. Packing unit: 3 piecesDetails
71389517Extension cable 2x type BL=180mm. Packing unit: 3 piecesDetails
TA30A-Terminal box TA30ARetainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
TA30D-Junction box TA30DRetainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
71182602Seal5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75Details
TMT31-F+ Temperature transmitter TMT312-wire temperature transmitter. Single sensor input. Application: RTD/TC. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC, presetting failure current low. Consider additional marine certificate requirements on application side.Enquire
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
TMT86-Temperature transmitter TMT862-wire Ethernet transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: CH1: Pt100, 4-wire, oC, CH2: inactive.Enquire
TMT71-Temperature transmitter TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.Enquire
TMT72-Temperature transmitter TMT722-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oCEnquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
71044061equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connectorDetails
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire
71244062ferrule threadMaximum temperature +350oC. Maximum pressure 1bar. Material 316Ti (1.4571). For pipe diameter 13.7...14mm. Dimension: A=G1/2, d=15.5mm, Wr=36.Details
71421272Compression fitting G1 15.5 mm, 316TiMaximum temperature +350oC. Maximum pressure 1bar. Material 316Ti (1.4571). For pipe diameter 13.7...14mm. Dimension: A=G1, d=15.5mm, Wr=41.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

All documents for this model
5 documents · click to expand
TI

TI iTHERM FlameLine TAF11, TAF12x, TAF16 Chinese

Rev. 1625 24 pages
Preview
TI

Omnigrad S TAF11, TAF12x, TAF16 Chinese

Rev. 1312 20 pages
Preview
TI

TI iTHERM FlameLine TAF11, TAF12x, TAF16 English

Rev. 1625 24 pages
Preview
TI

Omnigrad S TAF11, TAF12x, TAF16 Technical information English

Rev. 1413 20 pages
Preview
TI

Technical information English

Rev. 0111 26 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermocouples — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.

Food & Beverage

Food & Beverage · thermocouples — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermocouples — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · thermocouples — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.

Field Results