Technical Data
CompareThermometer
| Measuring Principle | |
| Characteristic / Application | metric style modular temperature assembly universal range of application suitable for hazardous areas process connection as compression fitting without neck incl. thermowell / protection tube (metal) |
| Thermowell / protection tube | welded protection tube |
| Insert / probe | mineral insulated (MI), flexible |
| Outer diameter protection tube / Insert | 9,0 mm (0,35'') 11,0 mm (0,43'') 12,0 mm (0,47'') |
| Max. immersion length on request | up to 10.000,00 mm (393,70'') |
| Material protection tube/ thermowell | 1.4404 (316L) 1.4571 (316Ti) Alloy 600 (2.4816) Alloy C276 (2.4819) |
| Optional coating | Not defined |
| Process connection | compression fitting: G1/2" G1" R1/2" R3/4" |
| Tip shape | straight reduced tapered |
| Surface roughness Ra | 0,8 μm (31,5 μin.) |
| Operating temperature range | Type K: max. 1.100 °C (max. 2.012 °F) Type J: max. 800 °C (max. 1.472 °F) |
| Max. process pressure (static) | at 20 °C: 40 bar (580 psi) |
| Accuracy | class 1 acc. to IEC 60584 |
| Response time | depending on configuration t50 = 6 s t90 = 13 s |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Ex - approvals | ATEX II ATEX IECEx NEPSI IECEx EAC Ex |
| Certification | Gost Metrology SIL (transmitter only) |
Flexibly configurable, robust thermometer suitable for applications in almost all industries. Devices with an optional head-mounted transmitter are compatible with all common communication protocols, are ready for immediate use and offer higher measuring accuracy and reliability than directly wired sensors. A wide range of process connections, versions and materials provides flexibility in use.
Benefits
Modular design with a standard terminal head conforming to DIN EN 50446 and customer-specific immersion length for high flexibility
Highly compatible measuring element, designed in accordance with DIN 43772
Short tapered/tapered tip for faster response time
Types of protection for use in hazardous areas: intrinsically safe (Ex ia), non-sparking (Ex nA)
Easy selection of the head transmitter: analog output 4 to 20 mA, HART®, PROFIBUS® PA or FF fieldbus
Spare Parts & Accessories 35
35 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 52028179 | gasketProfile gasket for cover Stainless steel housing F15 | Details |
| 71367420 | Copper sealing ringPacking unit: 10 pieces | Details |
| 71367427 | gasketPacking unit: 10 pieces | Details |
| 71313382 | Connector | Details |
| 71043745 | Atmospheric compensation filter portConsists of: filter plug plastic, Pressure compensation filter, O-ring. Usage: housing F15. Non Ex. | Details |
| TPC100- | Thermocouple armored core TPC100Replaceable insert (MgO) | Enquire |
| 71111514 | Ceramic terminal block | Details |
| 71111510 | Ceramic terminal block | Details |
| 71249291 | Heat Transfer Oil, FDA Certified, 30 g | Details |
| 71312729 | Heat transfer oil HSC 340, 100 g | Details |
| 71389497 | Extension wire TC IEC 2x type JL=180mm. Packing unit: 3 pieces | Details |
| 71389488 | Extension wire TC IEC 2x type KL=180mm. Packing unit: 3 pieces | Details |
| TXU10- | Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线 | Enquire |
| READWIN- | Readwin 2000 Commissioning Package READWINReadwin 2000 Operation + Read. software | Enquire |
| FXA195- | Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508. | Enquire |
| TA30A- | Terminal box TA30ARetainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing). | Enquire |
| TA30D- | Junction box TA30DRetainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing). | Enquire |
| 71182602 | Seal5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75 | Details |
| TA30P- | Junction Box TA30PRetainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: Polyamid PA12 antistatic. Colour: black. Ambient temp.: -40...120oC (housing). Protection: IP65 (housing). | Enquire |
| TA21E- | Junction box TA21ERetainer for terminal block or head transmitter. Cover: srewable. Material: Aluminum. Max. temp.: +100 oC; ATEX +95 oC. Protection: IP65. | Enquire |
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Measuring principle video
Click to playManuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · thermocouples — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.
Solution
The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.
Food & Beverage · thermocouples — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.
Configuration
Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.
Chemical & Pharmaceutical · thermocouples — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.
What We Did
We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.
Power & Energy · thermocouples — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.
Delivery Approach
Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.
Related Products
Endress+HauseriTHERM ModuLine TM121
Endress+HauseriTHERM MultiSens Slim TMS21
Endress+HauserThermocouple sensor, wire probe
Endress+HauserThermocouple TC63
Endress+HauseriTHERM FlameLine TAF12D
Endress+HauseriTHERM FlameLine TAF11
Endress+HauserThermocouple TC10
Endress+Hauser