Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TC13 ThermocoupleDiscontinued

TC13 Thermocouple
Thermocouple TC13Discontinued
The high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.
Compare

Thermometer

Measuring Principle
Characteristic / Application metric style
modular temperature assembly
universal range of application
suitable for hazardous areas
flanged process connection
without neck
incl. thermowell / protection tube (metal)
Thermowell / protection tube welded protection tube
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 9,0 mm (0,35'')
11,0 mm (0,43'')
12,0 mm (0,47'')
Max. immersion length on request up to 10.000,00 mm (393,70'')
Material protection tube/ thermowell 1.4404 (316L)
1.4571 (316Ti)
Alloy 600 (2.4816)
Alloy C276 (2.4819)
Optional coating Not defined
Process connection flange:
DN25 PN40 B1 (EN1092)
DN40 PN40 B1(EN1092)
DN50 PN40 B1 (EN1092)
ASME 1" 150 RF (B16.5)
ASME 1" 300 RF (B16.5)
Tip shape straight
reduced
tapered
Surface roughness Ra 0,8 μm (31,5 μin.)
Operating temperature range Type K:
-40 °C ... 1.100 °C
(-40 °F ...2.012 °F)
Type J:
-40 °C ...750 °C
(-40 °F ...1.382 °F)
Max. process pressure (static) at 20 °C: 50 bar (725 psi)
Accuracy class 1 acc. to IEC 60584
Response time depending on configuration
t50 = 6 s
t90 = 13 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX II
ATEX IECEx
NEPSI
IECEx Ex
EAC Ex
Certification Gost Metrology
SIL (transmitter only)

A highly modular, robust thermometer suitable for almost all industrial applications. Devices with an optional head transmitter are compatible with all common communication protocols and can be installed and used immediately, improving measuring accuracy and reliability compared to directly wired sensors. A wide range of process connections, specifications and materials provides application flexibility.

 

Advantages

Modular design with a standard terminal head in accordance with DIN EN 50446 and customer-specified immersion length for high flexibility

High insert compatibility, designed in accordance with DIN 43772

Extension neck prevents the head transmitter from overheating

Short-taper/conical tip for a faster response time

Protection types for use in hazardous locations: intrinsically safe (Ex ia), non-sparking (Ex nA)

Easy head transmitter selection: analog output 4 to 20 mA, HART®, PROFIBUS® PA or FF Fieldbus

Spare Parts & Accessories 32

32 spare parts · click to collapse
Order codeDescription
71312729Heat transfer oil HSC 340, 100 gDetails
71249291Heat Transfer Oil, FDA Certified, 30 gDetails
52028179gasketProfile gasket for cover Stainless steel housing F15Details
60017971DisplayDisplay LC for TA20JDetails
71043745Atmospheric compensation filter portConsists of: filter plug plastic, Pressure compensation filter, O-ring. Usage: housing F15. Non Ex.Details
71313382ConnectorDetails
71367427gasketPacking unit: 10 piecesDetails
71044061equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connectorDetails
71111510Ceramic terminal blockDetails
71111514Ceramic terminal blockDetails
71389488Extension wire TC IEC 2x type KL=180mm. Packing unit: 3 piecesDetails
71389497Extension wire TC IEC 2x type JL=180mm. Packing unit: 3 piecesDetails
TPC100-Thermocouple armored core TPC100Replaceable insert (MgO)Enquire
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
71586415Spare parts kit O-ring TA20R44.17x1.78 EPDM labs free, black, Packing unit: 5 piecesDetails
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
4 documents · click to expand
TI

TR13、TC13 Chinese

Rev. 0522 28 pages
Preview
TI

技术资料 Omnigrad M TC13 热电偶(TC) 温度计 Chinese

Rev. 0204 12 pages
Preview
TI

TR13, TC13 English

Rev. 0522 28 pages
Preview
TI

Technical information TC 13, Omnigrad M English

Rev. 0204 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermocouples — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.

Food & Beverage

Food & Beverage · thermocouples — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermocouples — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · thermocouples — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.