Technical Data
CompareThermometer
| Measuring Principle | |
| Characteristic / Application | US style modular temperature assembly for heavy duty applications suitable for hazardous areas threaded process connection with neck to use with thermowell |
| Thermowell / protection tube | to use with thermowell |
| Insert / probe | replaceable (without process interruption) |
| Outer diameter protection tube / Insert | Insert Diameter 6,0 mm (0,24'') |
| Max. immersion length on request | up to 30.000,00 mm (1.181,10'') |
| Material protection tube/ thermowell | Not defined |
| Optional coating | Not defined |
| Process connection | male thread: NPT1/2" |
| Tip shape | straight |
| Surface roughness Ra | 0,8 μm (31,5 μin.) |
| Operating temperature range | Type K: -40 °C ...1.100 °C (-40 °F ...2.012 °F) Type J: -40 °C ...750 °C (-40 °F ...1.382 °F) |
| Max. process pressure (static) | at 20 °C: 500 bar (7.252 psi) |
| Accuracy | class 1 acc. to IEC 60584 |
| Response time | depending on configuration t50 = 3 s t90 = 7 s |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Ex - approvals | ATEX II IECEx NEPSI EAC Ex Explosion proof |
| Certification | Gost Metrology SIL (transmitter only) |
This thermocouple thermometer is robust and suitable for harsh operating conditions and demanding safety applications in the chemical, oil, gas and energy industries. The sensor is fitted with a separate thermowell. The optional transmitter is compatible with all common communication protocols, is ready for immediate use and offers higher measuring accuracy and reliability than directly wired sensors. The modular design offers a wide range of combinations to suit different measuring tasks.
Benefits
Explosion protection types: intrinsically safe (Ex ia), flameproof (Ex d), non-sparking (Ex nA)
Modular design with a standard terminal head conforming to DIN EN 50446 and customer-specific insertion length for high flexibility
Highly compatible measuring insert, designed in accordance with DIN 43772
Extension neck and NUN connection prevent the transmitter from overheating
Application
Heavy-duty mechanical applications
Oil and gas industry
Measuring range: –40 ... 1 100 °C (–40 ... 2 012 °F)
Degree of protection: IP68
Spare Parts & Accessories 24
24 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71249291 | Heat Transfer Oil, FDA Certified, 30 g | Details |
| 71312729 | Heat transfer oil HSC 340, 100 g | Details |
| 71044061 | equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector | Details |
| 71111510 | Ceramic terminal block | Details |
| 71111514 | Ceramic terminal block | Details |
| TPC100- | Thermocouple armored core TPC100Replaceable insert (MgO) | Enquire |
| TPC300- | Thermocouple Armored Core TPC300Replaceable insert (MgO) to use with TC6x line. | Enquire |
| TA21H- | Terminal head TA21HProduct Phased Out. Retainer for terminal block or head transmitter. Design: explosion proof. Cover: screwed. Ambient temp.: -40...100 oC (housing). Protection: IP66/68 (housing). | Enquire |
| TMT85- | Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. | Enquire |
| TMT84- | Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable. | Enquire |
| TMT82- | Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | Enquire |
| TMT85- | Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. | Enquire |
| TMT84- | Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable. | Enquire |
| TMT82- | Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | Enquire |
| TID10- | Temperature transmitter display TID10to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84. | Enquire |
| TXU10- | Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线 | Enquire |
| READWIN- | Readwin 2000 Commissioning Package READWINReadwin 2000 Operation + Read. software | Enquire |
| 71182599 | Spare parts kit 5xO-Ring 74x3 VMQ 75Material Phased Out. | Details |
| TA30H- | Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing). | Enquire |
| TMT181- | iTEMP TMT181, Head Transmitter PCPProduct being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed. | Enquire |
Configurator / Comparison
Measuring principle video
Click to playManuals & Documents 3
All documents for this modelCase Studies
Municipal Wastewater Treatment · thermocouples — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.
Solution
The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.
Food & Beverage · thermocouples — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.
Configuration
Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.
Chemical & Pharmaceutical · thermocouples — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.
What We Did
We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.
Power & Energy · thermocouples — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.
Delivery Approach
Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.