Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TC65 Thermocouple

TC65 Thermocouple
Thermocouple TC65
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. The sensor may be used direct contact without thermowell or where the application requires it, spring load inside of a separate thermowell. Flexible configuration possible.
Compare

Thermometer

Measuring Principle Thermocouple
Characteristic / Application metric style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
threaded process connection
without neck
Thermowell / protection tube without (not intended to use with thermowell)
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 3,0 mm (0,12'')
6,0 mm (0,24'')
Max. immersion length on request up to 30.000,00 mm (1.181,10'')
Material protection tube/ thermowell 1.4404 (316L)
Alloy 600 (2.4816)
Process connection male thread:
NPT1/2"
NPT3/4"
compression fitting:
NPT1/2"
NPT3/4"
Tip shape straight
tapered
Operating temperature range Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 800 °C
(max. 1.472 °F)
Max. process pressure (static) at 20 °C: 80 bar (1,160 psi)
Accuracy class 1 acc. to IEC 60584
Response time depending on configuration
t50 = 3 s
t90 = 7 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX Ex ia, Ex d, Ex nA
IECEx Ex ia, Ex d, Ex tD
NEPSI Ex ia, Ex d
EAC Ex ia, Ex d
Explosion proof
Certification Gost Metrology
SIL (transmitter only)

This thermocouple thermometer is robust and suitable for harsh operating conditions and safety-critical measuring applications in the chemical, oil, gas and energy industries. The optional transmitter is compatible with various common communication protocols and can be installed and used immediately, improving measuring accuracy and reliability compared to directly wired sensors. The sensor can come into direct contact with the medium or use a spring-loaded thermowell, allowing flexible equipment configuration.

 

Advantages

Explosion protection types: intrinsically safe (Ex ia), flameproof (Ex d), non-sparking (Ex nA)

High measuring insert compatibility, designed in accordance with DIN 43772

Modular design with a standard terminal head in accordance with DIN EN 50446 and customer-specified insertion depth for high flexibility

 

Application areas

Fine chemicals

Petrochemical industry

Power plants

Environmental engineering

Measuring range: –40 to 1 100 °C (–40 to 2 012 °F)

Static pressure up to 75 bar depending on the process connection used

Degree of protection: IP68

Spare Parts & Accessories 14

14 spare parts · click to collapse
Order codeDescription
TA30H-Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).Enquire
71600564O-ring 74x3 75° VMQ silicone rubberPacking unit: 5 piecesDetails
TA50-Mounting parts, compression fitting TA50Screw in.Enquire
71744221Spare part kit TA50-GB/NB/HB/PB/BB/CB/DBPacking unit: 10 pieces, d=6.1mm. Material: 316/1.4401.Details
TMT31-F+ Temperature transmitter TMT312-wire temperature transmitter. Single sensor input. Application: RTD/TC. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC, presetting failure current low. Consider additional marine certificate requirements on application side.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
TMT182-*** module temperature transmitter TMT182Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, SIL2, galvanic isolation Fault reaction: NAMUR NE 43. Mounting: head form B, DIN43729. UL listed. GL (German Llyod) Marine.Enquire
TID10-Temperature transmitter display TID10to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84.Enquire
71044061equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connectorDetails
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
READWIN-Readwin 2000 Commissioning Package READWINReadwin 2000 Operation + Read. softwareEnquire
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
5 documents · click to expand
BA

BA iTHERM ModuLine工业温度计 Chinese

Rev. 0325 24 pages
Preview
BA

BA iTHERM ModuLine thermometer English

Rev. 0325 28 pages
Preview
TI

Omnigrad S TR65, TC65 技术资料 Chinese

Rev. 0216 16 pages
Preview
TI

Technical Information Omnigrad S TC65 English

Rev. 0705 10 pages
Preview
TI

Omnigrad S TR65, TC65 Technical Information English

Rev. 0216 20 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermocouples — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.

Food & Beverage

Food & Beverage · thermocouples — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermocouples — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · thermocouples — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.