Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TH15 RTD Assembly TH15, Spring US Style

TH15 RTD Assembly TH15, Spring US Style
RTD Assembly TH15, Spring US Style
The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application Industrial US style
modular temperature assembly
with extension
to be used with existing thermowell
Thermowell / protection tube to be used with thermowell
Insert / probe mineral insulated (MI), flexible
PTFE-insulated, rigid
Outer diameter protection tube / Insert Insert 1/4'' (6,35 mm)
Max. immersion length on request up to 41" (1041 mm)
others on request
Material protection tube/ thermowell Sensor sheath
316/316L
Optional coating Not applicable
Process connection Schutzrohranschluss
Außen-Gewinde:
NPT1/2"
1-1/4"-18 UNEF
Tip shape straight
Surface roughness Ra Not defined
Operating temperature range PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
iTHERM StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static) not applicable
Accuracy class A acc. to IEC 60751
class B acc. to IEC 60751
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals transmitter only
FM IS
CSA IS
FM/CSA IS
Certification SIL (transmitter only)

The robust thermometer consists of a protection tube and a connection head that can be fitted with different transmitter types to meet different application environments and space requirements. The thermometer offers high measuring accuracy and reliability and is available with various process connections, dimensions and materials (e.g. 316L SS and Hastelloy C276) for flexible use in a wide range of applications.

Advantages

  • Modular thermometer with standard connection head and user-defined insertion depth for flexible use

  • One-stop temperature measurement solution. First-class transmitter with integrated sensor for demanding industrial process applications. Install and use directly after unpacking

  • Improved electrical isolation (2 kV) when installed on most devices

  • Simple modular structure: excellent value for money. Easy ordering and reordering. The complete unit with sensor and transmitter provides a complete measuring point solution

  • Long-term stability of all iTEMP® transmitters ≤ 0.05 %/year

  • Stepped/tapered tip for a short response time

  • Simple selection of modular transmitter: 4...20 mA analog output, HART®, PROFIBUS® PA or FOUNDATION Fieldbus (FF™)

Application

  • TH15 is a resistance thermometer (RTD) installed in a thermowell, with a robust structure suitable for various industrial processes including harsh conditions. It consists of an insulated resistance (RTD) measuring probe and a mineral-insulated insert.

  • The sensor can be used for:

  • Chemical industry

  • Petrochemical industry

  • Power plants

  • Refineries

  • Offshore platforms

Spare Parts & Accessories 39

39 spare parts · click to collapse
Order codeDescription
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
51007995mounting bracketMounting bracket SS316L, tube 1,5-3"Details
TMT162X-Spare part TMT162XEnquire
TMT162A-TMT162A accessoriesProduct Phased Out.Enquire
71111513Ceramic terminal blockDetails
71111514Ceramic terminal blockDetails
71502617O-ring 88x3 HNBR 70° Shore PTFE_5pcsPacking unit: 5 piecesDetails
71600564O-ring 74x3 75° VMQ silicone rubberPacking unit: 5 piecesDetails
71182606Seal5x O-ring 57x2.5 5x O-ring 64.3x1.8 blauDetails
TS212-iTHERM Insert imperial TS212Replaceable insert acc. IEC 60751. Imperial version with central spring load. ::Fastest response times for optimal process control through iTHERM QuickSens. ::Maximum robustness for highest process safety through iTHERM StrongSens.Enquire
TU111-General Purpose RTD Insert, TU111, U.S.Product being phased out, limited availability. Spare part. Spring loaded. General purpose. Pt100 sensor comply with IEC60751 standard, alpha=0.00385.Enquire
TU401-Enclosure TU401, US StyleProduct being phased out, limited availability.Enquire
TA30H-Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).Enquire
XPT0004-Spare Parts Kit Cover TA30Rcover of connecting headEnquire
TA30R-Terminal box TA30RRetainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temperature: -50...+85/+130oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact design and low weight.Enquire
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire
71386275Integrable Surge Arrester ModuleFor subsequent mounting in field transmitter. Ensure compatibility.Details
71044062equipment package2x screws, 1x sealing CDI-connectorDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

All documents for this model
1 documents · click to expand
TI

TI RTD TH13, TH14 and TH15 English

Rev. 1824 28 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.