Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TH51 Modular thermocouple thermometer

TH51 Modular thermocouple thermometer
Modular thermocouple thermometer
The high modular thermometer is used for several applications in almost all industries. Examples are heat exchangers, furnaces, dryers, process reactors, etc. With different head transmitter it's a complete unit ready for use with enhanced measurement accuracy and reliability. It also enables very fast response times, due to direct contact measurement without thermowell. A variety of process connections and dimensions offer flexible application possibilities.
Compare

Thermometer

Measuring Principle Thermocouple
Characteristic / Application US style
modular temperature assembly
threaded process connection
Thermowell / protection tube without (not intended to use with thermowell)
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 1/8'' (3,18 mm)
3/16''(4,76 mm)
1/4'' (6,35 mm)
3/8'' (9,53 mm)
Max. immersion length on request up to 96" (2.438 mm)
others on request
Material protection tube/ thermowell 316
Alloy 600
Optional coating Not applicable
Process connection male thread:
G1/2"
NPT1/2"
compression fitting:
NPT1/8"
NPT1/4"
Tip shape straight
Surface roughness Ra Not defined
Operating temperature range Type T:
-270 °C ...400 °C
(-454 °F ...752 °F)
Type J:
-210 °C ...1.200 °C
(-346 °F ...2.192 °F)
Type E:
-270 °C ...1.000 °C
(-454 °F ...1.832 °F)
Type K:
-270 °C ...1.372 °C
(-454 °F ...2.500 °F)
Type N:
-270 °C ... 1.300 °C
(-454 °F ...2.372 °F)
Max. process pressure (static) at 20°C: 250 bar (3.626 psi)
depends on configuration
Accuracy Standard acc. to ASTM E-230
Special acc. to ASTM E-230
Response time 63% rt = 0.3 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals transmitter only
FM IS
CSA IS
FM/CSA IS
Certification SIL (transmitter only)

Product Overview

The highly modular thermometer is suitable for a wide range of applications in almost all industries, e.g. heat exchangers, furnaces, dryers, process reactors, etc. Combined with various modular transmitters it forms a complete measuring system with higher measuring accuracy and reliability. No thermowell is required; it can be wired directly for measurement with a short response time. Various process connections and dimensions are available to flexibly meet application requirements.

  • Advantages

  • One-stop temperature measurement solution. First-class transmitter with integrated sensor for demanding industrial process applications. Install and use directly after unpacking

  • Improved electrical isolation (2 kV) when installed on most devices

  • Simple modular structure: excellent value for money. Easy ordering and reordering. The complete unit with sensor and transmitter provides a complete measuring point solution

  • Long-term stability of all iTEMP® transmitters ≤ 0.05 %/year

  • Application

  • Magnesium-oxide-insulated thermocouples (commonly known as MgO thermocouples) are suitable for many process and laboratory applications. Thermocouples have many desirable properties and are a good choice for conventional and special applications.

  • The sensor can be used for:

  • Heat exchangers

  • Energy recovery areas

  • Furnaces

  • Dryers

  • Flue gas

  • Compressor stations

  • Process reactors

  • Metallurgy and glass manufacturing

Spare Parts & Accessories 45

45 spare parts · click to collapse
Order codeDescription
52028179gasketProfile gasket for cover Stainless steel housing F15Details
60017971DisplayDisplay LC for TA20JDetails
71043745Atmospheric compensation filter portConsists of: filter plug plastic, Pressure compensation filter, O-ring. Usage: housing F15. Non Ex.Details
XPT0004-Spare Parts Kit Cover TA30Rcover of connecting headEnquire
TA30H-Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).Enquire
TA30R-Terminal box TA30RRetainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temperature: -50...+85/+130oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact design and low weight.Enquire
DIENST-ServiceAttention: Please note the instructions for DIENST-F/T in the option text!Enquire
TU301-ferrule threadProduct being phased out, limited availability.Enquire
TU401-Enclosure TU401, US StyleProduct being phased out, limited availability.Enquire
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire
71044062equipment package2x screws, 1x sealing CDI-connectorDetails
TID10-Temperature transmitter display TID10to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84.Enquire
TMT71-Temperature transmitter TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.Enquire
TMT72-Temperature transmitter TMT722-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oCEnquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
TMT86-Temperature transmitter TMT862-wire Ethernet transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: CH1: Pt100, 4-wire, oC, CH2: inactive.Enquire
TMT142E-Electronic module TMT142EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

All documents for this model
1 documents · click to expand
TI

TI TH51, TH52 and TH56 English

Rev. 1725 28 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermocouples — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.

Food & Beverage

Food & Beverage · thermocouples — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermocouples — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · thermocouples — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.