Technical Data
CompareThermometer
| Measuring Principle | Thermocouple |
| Characteristic / Application | Industrial US style modular temperature assembly threaded, weld-in, and socket weld process connection with extension incl. thermowell |
| Thermowell / protection tube | bar stock (drilled) |
| Insert / probe | mineral insulated (MI), flexible |
| Outer diameter protection tube / Insert | 3/4'' (19,05 mm) 7/8'' (22,23 mm) 1'' (25,40 mm) 17/16'' (26,99 mm) 0,63'' ...1,31'' (15,88 mm ... 33,40 mm) |
| Max. immersion length on request | up to 24'' (609 mm) others on request |
| Material protection tube/ thermowell | 316/316L others on request |
| Optional coating | Available on request |
| Process connection | male thread: NPT1/2" NPT3/4" NPT1" weld in version socket weld version |
| Tip shape | straight stepped tapered |
| Surface roughness Ra | 32 μin (0.80 μm) |
| Operating temperature range | Type T: -270 °C ...400 °C (-454 °F ...752 °F) Type J: -210 °C ... 1.200 °C (-346 °F ...2.192 °F) Type E: -270 °C ... 1.000 °C (-454 °F ...1.832 °F) Type K: -270 °C ...1.372 °C (-454 °F ...2.500 °F) Type N: -270 °C ... 1.300 °C (-454 °F ...2.372 °F) |
| Max. process pressure (static) | at 20°C: 100 bar (1.450psi) depends on configuration |
| Accuracy | Standard acc. to ASTM E-230 Special acc. to ASTM E-230 |
| Response time | depending on configuration 63% rt = 15 s |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Ex - approvals | transmitter only FM IS CSA IS FM/CSA IS |
| Certification | SIL (transmitter only) |
The highly modular thermometer is suitable for many applications under harsh conditions, e.g. power plants, refineries, chemical or petrochemical industries. The robust thermometer uses a bar stock thermowell and, combined with different modular transmitters, forms a complete measuring unit for direct measurement with high measuring accuracy and reliability. Various process connections, dimensions and materials are available, e.g. SS316, INCONEL 600, Hastelloy C276 alloy, titanium or Monel, for flexible use.
Advantages
-
One-stop temperature measurement solution. First-class transmitter with integrated sensor for demanding industrial process applications.
-
Install and use directly after unpacking
-
Improved electrical isolation (2 kV) when installed on most devices
-
Simple modular structure: excellent value for money. Easy ordering and reordering. The complete unit with sensor, thermowell and transmitter provides a complete measuring point solution
-
Long-term stability of all iTEMP® transmitters ≤ 0.05 %/year
Application
-
TH13 is a thermocouple (TC) thermometer installed in a thermowell, with a robust structure suitable for various industrial processes including harsh conditions. It consists of a magnesium-oxide-insulated thermocouple measuring probe and a bar stock thermowell.
-
The sensor is suitable for the following industries:
-
Chemical industry
-
Petrochemical industry
-
Power plants
-
Refineries
-
Offshore platforms
Spare Parts & Accessories 40
40 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| TU401- | Enclosure TU401, US StyleProduct being phased out, limited availability. | Enquire |
| TA30H- | Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing). | Enquire |
| TA30R- | Terminal box TA30RRetainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temperature: -50...+85/+130oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact design and low weight. | Enquire |
| XPT0004- | Spare Parts Kit Cover TA30Rcover of connecting head | Enquire |
| 60017971 | DisplayDisplay LC for TA20J | Details |
| TMT71- | Temperature transmitter TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC. | Enquire |
| TMT72- | Temperature transmitter TMT722-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC | Enquire |
| TMT84- | Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable. | Enquire |
| TMT82- | Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | Enquire |
| TMT85- | Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. | Enquire |
| TMT86- | Temperature transmitter TMT862-wire Ethernet transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: CH1: Pt100, 4-wire, oC, CH2: inactive. | Enquire |
| 71044062 | equipment package2x screws, 1x sealing CDI-connector | Details |
| TID10- | Temperature transmitter display TID10to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84. | Enquire |
| 71310423 | Display housing fixing kit (3 pcs) | Details |
| TMT142X- | Spare Part TMT142XSpare parts TMT142X | Enquire |
| TMT142E- | Electronic module TMT142EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1. | Enquire |
| TMT142G- | Housing TMT142GHousing TMT142G | Enquire |
| TMT142X- | Spare Part TMT142XSpare parts TMT142X | Enquire |
| TMT142E- | Electronic module TMT142EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1. | Enquire |
| TMT142G- | Housing TMT142GHousing TMT142G | Enquire |
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Manuals & Documents 1
All documents for this model1 documents · click to expand
TI TH53, TH54 and TH55 English
Case Studies
Municipal Wastewater Treatment · thermocouples — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.
Solution
The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.
Food & Beverage · thermocouples — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.
Configuration
Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.
Chemical & Pharmaceutical · thermocouples — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.
What We Did
We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.
Power & Energy · thermocouples — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.
Delivery Approach
Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.
Related Products
Endress+HauseriTHERM ModuLine TM121
Endress+HauseriTHERM MultiSens Slim TMS21
Endress+HauserThermocouple sensor, wire probe
Endress+HauserThermocouple TC63
Endress+HauseriTHERM FlameLine TAF12D
Endress+HauseriTHERM FlameLine TAF11
Endress+HauserThermocouple TC10
Endress+Hauser