Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TM152 Modular industrial thermometer

TM152 Modular industrial thermometer
Modular industrial thermometer
The modular industrial RTD or TC thermometer iTHERM ModuLine TM152 is complete with barstock thermowell or to be used with onsite thermowell. It is suitable for every application, from basic functionality to high-end performance in the chemical, oil & gas and power & energy industries.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application imperial style
modular temperature assembly
universal range of application
suitable for hazardous areas
suitable for high process pressures
with neck or iTHERM QuickNeck
incl. thermowell / protection tube (metal) or to be installed into thermowell
can be used with iTHERM StrongSens
Thermowell / protection tube barstock (drilled) or to be used with thermowell
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 5/8" (15.88 mm)
3/4" (19.05 mm)
7/8" (22.2 mm)
1" (25.4 mm)
1.050" (26.7 mm)
1-1/16" (27 mm)
1-1/8" (28.58 mm)
1-1/4" (31.75 mm)
1.315" (33.4 mm)
1-3/8" (34.93 mm)
1-1/2" (38.1 mm)
1.660" (42.16 mm)
1.900" (48.26 mm)
Max. immersion length on request 84"
Material protection tube/ thermowell 316/316L
304/304L
Alloy600
AlloyC276
A182 F22
A182 F11
A182 F91
A105
Duplex
Optional coating PTFE coated
Tantalum sleeve
Process connection Male thread:
G1/2", G3/4"
NPT1/2", NPT3/4", NPT 1", NPT 1-1/4", NPT 1-1/2"
Innen-Gewinde:
NPT1/2"
Flansche:
ASME 1" 150 RF
ASME 1" 300 RF
ASME 1" 600 RF
ASME 1" 900/1500 RF
ASME 1 1/2" 150 RF
ASME 1 1/2" 300 RF
ASME 1 1/2" 600 RF
ASME 1 1/2" 900/1500 RF
ASME 2" 150 RF
ASME 2" 300 RF
ASME 2" 600 RF
zum Einschweißen:
NPS 3/4" (26.7 mm)
NPS 1" (33.4 mm)
NPS 1-1/4" (42.2 mm)
NPS 1-1/2" (48.3 mm)
1-3/8" (34.92 mm)
Tip shape straight
tapered
stepped
Surface roughness Ra 0,76 μm (30 μin.)
1,6 μm (63,0 μin.)
Operating temperature range PT100 TF iTHERM StrongSens:
-50 °C ...500 °C
(-58 °F ...932 °F)
PT100 TF iTHERM QuickSens:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 basic TF:
-50 °C ...200 °C
(-58 °F ...392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F)
Max. process pressure (static) depending on the configuration up to 500 bar
Accuracy Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2
Response time depending on configuration
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX Ex ec
ATEX IECEx Ex ia
CSA C/US IS, NI, XP, DIP
INMETRO Ex ia
Certification SIL (Transmitter), CRN

iTHERM ModuLine TM152 modular industrial thermometer, RTD or thermocouple thermometer (imperial instrument) with integrated bar stock thermowell, widely used in industry

Advantages

  • Easy maintenance and recalibration of the thermometer (sensor replacement without interrupting the process)

  • Secondary sealing technology:Second process seal with fault indication function, providing useful information on the device health status

  • iTHERM QuickSens:Fast response with a response time of only 1.5 seconds, helping to optimize process control

  • iTHERM StrongSens:Superior vibration resistance (> 60g), ensuring high plant safety

  • iTHERM QuickNeck:Convenient removal of the thermometer without additional tools for recalibration of the device, saving cost and time

  • Numerous international certifications:Explosion protection certifications ATEX, IECEx, CSA and INMETRO; SIL functional safety certification

  • The iTEMP temperature transmitter supportsall common communication protocols, and can beoptionally equipped with Bluetooth® wireless connection

 

Field of application

The modular industrial RTD or thermocouple thermometer iTHERM ModuLine TM152 comes with an integrated bar stock thermowell or is used with an existing thermowell. It is very versatile, ranging from versions with basic functions to high-performance versions for the chemical, oil and gas, and power and energy industries.

  • Wide range of applications

  • Measuring range: –200...+1,100°C (–328...+2,012°F)

  • Maximum pressure rating: 500 bar (7,252 psi)

 

Spare Parts & Accessories 36

36 spare parts · click to collapse
Order codeDescription
TA30A-Terminal box TA30ARetainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
TA30D-Junction box TA30DRetainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
71182602Seal5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75Details
TA30P-Junction Box TA30PRetainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: Polyamid PA12 antistatic. Colour: black. Ambient temp.: -40...120oC (housing). Protection: IP65 (housing).Enquire
71182606Seal5x O-ring 57x2.5 5x O-ring 64.3x1.8 blauDetails
XPT0004-Spare Parts Kit Cover TA30Rcover of connecting headEnquire
TA30R-Terminal box TA30RRetainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temperature: -50...+85/+130oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact design and low weight.Enquire
TA30EB-Terminal Head TA30EBRetainer for terminal block or head transmitter + optional display. Cover: low, threaded, optional window. Material: Aluminum. Coating: Polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...+150oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
TA30H-Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).Enquire
XPT0002-plug connectorEnquire
XPT0002-plug connectorEnquire
XPT0002-plug connectorEnquire
510046541/2" NPT cable glandfor 2 sensorsDetails
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
TMT31-F+ Temperature transmitter TMT312-wire temperature transmitter. Single sensor input. Application: RTD/TC. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC, presetting failure current low. Consider additional marine certificate requirements on application side.Enquire
TMT36-F+ IO-Link Temperature Transmitter TMT362-wire temperature transmitter. Single sensor input. Application: RTD. Factory setup w/o additional specification: Pt100, 4-wire, oC. Mounting: head form B, DIN EN50446.Enquire
TMT71-Temperature transmitter TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.Enquire
TMT72-Temperature transmitter TMT722-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oCEnquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
4 documents · click to expand
BA

BA iTHERM ModuLine工业温度计 Chinese

Rev. 0325 24 pages
Preview
BA

BA iTHERM ModuLine thermometer English

Rev. 0325 28 pages
Preview
TI

TI iTHERM ModuLine TM152 Chinese

Rev. 0124 52 pages
Preview
TI

TI iTHERM ModuLine TM152 English

Rev. 0225 64 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.