Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TM401 iTHERM ModuLine

TM401 iTHERM ModuLine
iTHERM ModuLine TM401
This iTHERM thermometer has been designed to meet the basic requirements of the Food & Beverages and Life Sciences industries at the best price. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. The device uses basic technology with features such as a fixed, non-replaceable insert, a wide range of process connections and international certification at an excellent value for money.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
hygienic applications
aseptic applications
hygienic process connections
with neck
Thermowell / protection tube without (not intended to use with thermowell)
Insert / probe without exchangeable insert
Outer diameter protection tube / Insert 6,0 mm (0,24")
8,0 mm (0,31")
Max. immersion length on request up to 400 mm (15,75")
Material protection tube/ thermowell 316L
Process connection compression fitting
triclamp
microclamp
clamp connections acc. to ISO2852
Ingold
G3/4" Liquiphant
G1" Liquiphant
Varivent
SMS 1147
screwed pipe joint acc. to DIN 11851
Tip shape straight
reduced
Surface roughness Ra 0,76 μm (30 μin)
0,38 μm (15 μin)
Operating temperature range PT100:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static) at 20 °C: 40 bar (580 psi)
Accuracy class A acc. to IEC 60751
Response time depending on configuration
Integration head transmitter yes (4 ... 20 mA, HART)
Certification SIL (transmitter only)

The iTHERM thermometer is designed to meet the basic requirements of the food & beverage and life sciences industries at an optimum price. As a standard product with a clearly defined market segment, it is available in a wide range of versions. As a result, product selection is quick and simple, saving time and costs. The basic technology used in the device has the following features: fixed, non-replaceable measuring element, suitable for use in non-hazardous areas, standard extension neck and low cost.

 

Benefits

Excellent value for money and fast delivery

User-friendly and reliable from product selection through to maintenance

International certifications: hygiene standards compliant with 3-A®, EHEDG, ASME BPE, FDA and TSE requirements, certificate of suitability

Wide range of process connections

Spare Parts & Accessories 41

41 spare parts · click to collapse
Order codeDescription
TA30A-Terminal box TA30ARetainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
71182602Seal5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75Details
TA30R-Terminal box TA30RRetainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temperature: -50...+85/+130oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact design and low weight.Enquire
71182606Seal5x O-ring 57x2.5 5x O-ring 64.3x1.8 blauDetails
XPT0004-Spare Parts Kit Cover TA30Rcover of connecting headEnquire
TA30S-Terminal box TA30SRetainer for terminal block or head transmitter. Cover: screwed. Material: Polypropylene. Colour: white. Ambient Temperature: -30...+130oC. Protection: IP65, NEMA4X (housing). :: easy wiring through good accessibility. :: compact design, low weight.Enquire
XPT0002-plug connectorEnquire
71535692Plug screw fitting 316L M12x1.5Details
60022519screw plugDetails
TK40-iTHERM TK40 compression fitting threadWeld-in compression fitting with hygienic design. For applications in the food/ beverages and pharmaceutical industries.Enquire
XPT0001-Spare Part Kit Sealing for TK40 XPT0001delivery: 5 parts per kitEnquire
71215757Accessory kitDetails
52018765weld socketFlush mount process connection FTL20 "1", FTL20H "GDJ", FMI51, FTI51 "GQJ" Material: 316L, EHEDG compliant Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts)Details
52028295weld socketFlush mount process connection FTL20 "1", FTL20H "GDJ" w/o flange Material: 316L, EHEDG compliant Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts)Details
52021717O-ringfor weld-in adapter G3/4 D=50 316L Liquiphant T FTL20HDetails
52001052weld socketFlush mount process connection FTL50/FTL50H "GQ2" Material: 316L Seal: Silicone O-ringDetails
52011897weld socketFlush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, 3-A compliant. additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FTL41, FTL43, FTL50, FTL50H, FTL51B, FTL63, FTL80, QMW43, TMR35.Details
52014473O-ringfor weld-in adapter G3/4 Liquiphant M "GQ2"Details
52001051Process connection | Weld-in G1, d=60, 316L齐平安装式过程连接 FTL260 "0", FTL20 "7", FTL20H "GEJ", FTL330H/FTL330L "G", FTL50/FTL51, FTL50H/FTL51H "GW2", FMI51/FMI52, FTI51/FTI52 "GWJ", PMP135 "N", PTP35 "BB" 材质: 316L 密封: 硅橡胶 O-ringDetails
52011896Welding socket, G1, d=60, 3.1 material certificateFlush mount process connection FTL260 "0", FTL20H "GEJ", FTL50/FTL51, FTL50H/FTL51H "GW2", FMI51/FMI52, FTI51/FTI52 "GWJ", PMP135 "N", PTP35 "BB" Material: 316L Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts)Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
All documents for this model
6 documents · click to expand
BA

BA 模块化卫生温度计 Chinese

Rev. 0225 36 pages
Preview
BA

BA Modular hygienic thermometers English

Rev. 0225 36 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

TI iTHERM ModuLine TM401 Chinese

Rev. 0825 36 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI iTHERM ModuLine TM401 English

Rev. 0825 40 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.