Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TM412 卫生型温度计

TM412 卫生型温度计

iTHERM ModuLine TM412

It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application imperial style
modular temperature assembly
hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
hygienic process connections
with neck
suitable for hazardous areas
incl. protection tube
iTHERM QuickSens for fastest response time
iTHERM StrongSens for most robust design
iTHERM QuickNeck for easy and cost saving recalibration
Thermowell / protection tube without
incl. thermowell
incl. Tee-/elbow thermowell
Insert / probe mineral insulated (MI), flexible
pipe version, isolated wires, not flexible
Outer diameter protection tube / Insert 1/4'' (6,35 mm)
3/8'' (9,53 mm)
1/2" (12,7 mm)
Max. immersion length on request 48"
Material protection tube/ thermowell 316L
Process connection Weld-in adapter
Tri-clamp
Clamp-connections according to ISO2852
G3/4" Liquiphant
G1" Liquiphant
Varivent
T- and elbow thermowell
Tip shape straight
reduced
Surface roughness Ra 30 μin (0,76 μm)
15 μin (0,38 μm )
15 μin (0,38 μm) electropolished
Operating temperature range PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
iTHERM StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
iTHERM QuickSens:
-50 °C … 200 °C
(-58 °F … 392 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static) at 20 °C: 40 bar (580 psi)
Accuracy class B acc. to IEC 60751
class A acc. to IEC 60751
class AA acc. to IEC 60751
Response time depending on configuration
iTHERM QuickSens: t90 = 1,5 s
iTHERM StrongSens: t90 = 9,5 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX Ex nA
ATEX IECEx Ex ia, Ex tb
CSA C/US IS, NI
CSA NI
CSA IS, NI
FM NI
FM IS, NI
FM+CSA IS, NI
Certification SIL (transmitter only)

The thermometer meets the requirements of the food & beverage and life sciences industries and follows the highest quality standards. A wide range of product versions is available, making product selection simple and fast while saving time and costs. Several innovative technologies are used: iTHERM QuickSens, StrongSens or QuickNeck. Maintenance costs are significantly reduced while product quality, process efficiency and safety are increased.


Advantages
User-friendly and reliable from product selection through to maintenance
iTHERM thermowell insert: globally unique, fully automated production. Fully traceable, consistently high product quality ensures reliable measured values
iTHERM QuickSens: shortest response time (t90s: 1.5 s) for optimum process control
iTHERM StrongSens: outstanding vibration resistance (> 60 g), always ensuring plant safety
iTHERM QuickNeck: very simple recalibration without any additional tools, saving costs and time
iTHERM TA30R: 316L terminal head with simple operation, low installation and maintenance costs, maximum degree of protection IP69K
International approvals: explosion protection (e.g. ATEX, IECEx, FM, CSA), complies with hygienic standards (3-A, EHEDG, ASME BPE, FDA), TSE suitability certificate available


Application areas
Designed specifically for hygienic and aseptic applications in the food & beverage and life sciences industries
Measuring range: –200...+600 °C (–28...+1 112 °F)
Maximum pressure: 40 bar (580 psi)
Maximum degree of protection: IP69K

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · RTD Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · RTD Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · RTD Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · RTD Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.