Technical Data
CompareThermometer
| Measuring Principle | Resistance Temperature Detector |
| Characteristic / Application | metric style imperial style easy-to-use suitable for hazardous areas process connection: flanged light chemical processes linear sensor distribution modular design replaceable sensors during operation |
| Thermowell / protection tube | with one primary thermowell (for replaceable sensors and increased mechanical protection) |
| Insert / probe | mineral insulated (MI) sensors in a primary thermowell |
| Outer diameter protection tube / Insert | 48,3mm (1 1/2") 60,3mm (2") 76,1mm (2 1/2") 88,9mm (3") |
| Max. immersion length on request | up to 15.000,00 mm (590'') |
| Material protection tube/ thermowell | 1.4401 (316) 1.4435 (316L) 1.4541 (321) 1.4845 (310L) 1.4301 (304) 1.4307 (304L) |
| Process connection | flange: 1 1/2 " ASME/ANSI B16.5 150 ...900 2" ASME/ANSI B16.5 150 ...900 3" ASME/ANSI B16.5 150 ..900 DN40 EN/DIN 1092.1 PN10 ...PN150 DN50 EN/DIN 1092.1 PN10 ...PN150 DN80 EN/DIN 1092.1 PN10 ...PN150 |
| Tip shape | straight |
| Operating temperature range | Type K: max. 1.070 °C (max. 1.958 °F) Type J: max. 520 °C (max. 968 °F) Type N: max. 1.100 °C (max. 2.012 °F) Pt100 WW: -200...600 °C (-328…1.112 °F) Pt100 TF: -50…400 °C (-58…752 °F) |
| Max. process pressure (static) | at 20 °C: 240 bar (3481 psi) |
| Accuracy | class 1 acc. to IEC 60584 class Special ASTM E230 and ANSI MC 96.1 IEC60751 Class A IEC60751 Class AA |
| Response time | depending on configuration: TC: t50 = 21 s t90 = 52 s RTD: t50 = 42 s t90 = 108 s |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Ex - approvals | ATEX IECEx UL FM CSA NEPSI |
| Certification | SIL (transmitter only) |
iTHERM MultiSens Linear TMS11
Multipoint thermometer
Direct TC/RTD temperature profile solution with primary thermowell for oil, gas and petrochemical applications
Advantages
With primary thermowell offering excellent mechanical strength and easy replacement of individual inserts, which can use TC or RTD technology
Easy integration with inserts complying with IEC 60584, ASTM E230 and IEC 60751 standards
Complies with electrical and pressure directives for simple and fast process integration
Modular product design enables a high degree of customization, maximum flexibility, and easy installation and maintenance
Complies with various degrees of protection for use in hazardous areas
Individual inserts can be replaced even during operation
Continuous thermowell integrity monitoring via pressure port for maximum process safety
Field of application
The iTHERM TMS11 MultiSens linear multipoint thermometer is suitable for oil and gas as well as chemical applications and can be customized for various scenarios according to the highest safety standards. It monitors the temperature at a large number of measuring points on a production line using only a single process connection, thereby increasing process safety. Simple process integration reduces installation time and thus maximizes plant availability.
Spare Parts & Accessories 11
11 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| TMT31- | F+ Temperature transmitter TMT312-wire temperature transmitter. Single sensor input. Application: RTD/TC. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC, presetting failure current low. Consider additional marine certificate requirements on application side. | Enquire |
| TMT71- | Temperature transmitter TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC. | Enquire |
| TMT72- | Temperature transmitter TMT722-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC | Enquire |
| TMT82- | Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | Enquire |
| TMT84- | Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable. | Enquire |
| TMT85- | Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. | Enquire |
| TMT86- | Temperature transmitter TMT862-wire Ethernet transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: CH1: Pt100, 4-wire, oC, CH2: inactive. | Enquire |
| 71044061 | equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector | Details |
| 71044062 | equipment package2x screws, 1x sealing CDI-connector | Details |
| TMT162- | Field temperature transmitter TMT162Temperature transmitter. Application: RTD, TC, Ohm, mV. HART, PROFIBUS PA or FOUNDATION Fieldbus separately available. Galvanic isolation 2 kV (sensor input/output). NEMA 4x, IP67. Dual compartment. GL (German Lloyd)Marine (only HART). UL listed. | Enquire |
| TMT142B- | iTEMP Temperature Transmitter HART TMT142B2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC, presetting failure current low. | Enquire |
Configurator / Comparison
Technical documentation
Source:Endress+Hauserpublic information from the website
Measuring principle video
Click to playManuals & Documents 6
All documents for this model6 documents · click to expand
BA iTHERM多点温度计TMS12 Chinese
BA iTHERM TMS11 MultiSens Linear多点温度计 Chinese
BA iTHERM MultiSens Linear TMS12 English
BA iTHERM TMS11 MultiSens Linear English
TI iTHERM MultiSens Linear TMS11 多点温度计 Chinese
TI iTHERM MultiSens Linear TMS11 Multipoint thermometer English
Case Studies
Municipal Wastewater Treatment · thermocouples — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.
Solution
The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.
Food & Beverage · thermocouples — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.
Configuration
Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.
Chemical & Pharmaceutical · thermocouples — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.
What We Did
We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.
Power & Energy · thermocouples — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.
Delivery Approach
Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.
Related Products
Endress+HauseriTHERM ModuLine TM121
Endress+HauseriTHERM MultiSens Slim TMS21
Endress+HauserThermocouple sensor, wire probe
Endress+HauserThermocouple TC63
Endress+HauseriTHERM FlameLine TAF12D
Endress+HauseriTHERM FlameLine TAF11
Endress+HauserThermocouple TMT142C
Endress+Hauser