Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TMS11 多点温度计

TMS11 多点温度计

iTHERM MultiSens Linear TMS11

The iTHERM TMS11 MultiSens Linear Multipoint thermometer for oil & gas and chemical applications can be customized for various scenarios in compliance with the highest safety standards. It increases process safety by monitoring the temperature on a high number of measuring points along a line using only a single process connection. Easy process integration reduces installation time and thus maximizes plant availability.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
imperial style
easy-to-use
suitable for hazardous areas
process connection: flanged
light chemical processes
linear sensor distribution
modular design
replaceable sensors during operation
Thermowell / protection tube with one primary thermowell (for replaceable sensors and increased mechanical protection)
Insert / probe mineral insulated (MI) sensors in a primary thermowell
Outer diameter protection tube / Insert 48,3mm (1 1/2")
60,3mm (2")
76,1mm (2 1/2")
88,9mm (3")
Max. immersion length on request up to 15.000,00 mm (590'')
Material protection tube/ thermowell 1.4401 (316)
1.4435 (316L)
1.4541 (321)
1.4845 (310L)
1.4301 (304)
1.4307 (304L)
Process connection flange:
1 1/2 " ASME/ANSI B16.5 150
...900
2" ASME/ANSI B16.5 150
...900
3" ASME/ANSI B16.5 150
..900
DN40 EN/DIN 1092.1 PN10
...PN150
DN50 EN/DIN 1092.1 PN10
...PN150
DN80 EN/DIN 1092.1 PN10
...PN150
Tip shape straight
Operating temperature range Type K:
max. 1.070 °C
(max. 1.958 °F)
Type J:
max. 520 °C
(max. 968 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW:
-200...600 °C
(-328…1.112 °F)
Pt100 TF:
-50…400 °C
(-58…752 °F)
Max. process pressure (static) at 20 °C: 240 bar (3481 psi)
Accuracy class 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA
Response time depending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX
IECEx
UL
FM
CSA
NEPSI
Certification SIL (transmitter only)

iTHERM MultiSens Linear TMS11
Multipoint thermometer
Direct TC/RTD temperature profile solution with primary thermowell for oil, gas and petrochemical applications
Advantages
With primary thermowell offering excellent mechanical strength and easy replacement of individual inserts, which can use TC or RTD technology

Easy integration with inserts complying with IEC 60584, ASTM E230 and IEC 60751 standards

Complies with electrical and pressure directives for simple and fast process integration

Modular product design enables a high degree of customization, maximum flexibility, and easy installation and maintenance

Complies with various degrees of protection for use in hazardous areas

Individual inserts can be replaced even during operation

Continuous thermowell integrity monitoring via pressure port for maximum process safety
Field of application
The iTHERM TMS11 MultiSens linear multipoint thermometer is suitable for oil and gas as well as chemical applications and can be customized for various scenarios according to the highest safety standards. It monitors the temperature at a large number of measuring points on a production line using only a single process connection, thereby increasing process safety. Simple process integration reduces installation time and thus maximizes plant availability.

Oil and gas industry

Heavy chemical processes

Petrochemical industry

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

 

Technical documentation

  

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Thermocouple Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Thermocouple Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Thermocouple Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Thermocouple Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.