Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TMT162C 热电偶温度计

TMT162C 热电偶温度计

Thermocouple TMT162C

Endress+Hauser TMT162C
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. The thermometer fulfills the corresponding safety requirements due to various certificates and tests. The use of a transmitter leads to higher accuracy and reliability in comparison to directly wired sensors.
Compare

Thermometer

Measuring Principle
Characteristic / Application US style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
with neck
to use with thermowell
backlit display
Thermowell / protection tube to use with thermowell
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 6,0 mm (0,24'')
Max. immersion length on request up to 30.000,00 mm (1.181,10'')
Material protection tube/ thermowell Not defined
Optional coating Not defined
Process connection male thread:
G1/2"
NPT1/2"
NPT3/4"
M24x1.5
Tip shape straight
Operating temperature range Type K:
-40 °C ...800 °C
(-40 °F ...1.472 °F)
Type J:
-40 °C ...750 °C
(-40 °F ...1.382 °F)
Max. process pressure (static) up to 20 °C: 480 bar (6.962 psi)
Accuracy class 1 acc. to IEC 60584
class 2 acc. to IEC 60584
Response time depending on configuration
t50 = 3 s
t90 = 7 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX II
ATEX Eex
explosion proof
Certification Gost Metrology

A reliable thermometer designed specifically for safety-related applications in the oil and gas, chemical and power industries. Numerous approvals and tests ensure that the thermometer meets the relevant safety requirements. Used together with a transmitter, it achieves higher accuracy and reliability than direct sensor measurement.

 

Advantages

Dual-compartment housing

Backlit display with large measured value, bar graph and error alarm indication

2 kV galvanic isolation (sensor input/output)

Thermowell with numerous threaded connections as standard option

Replaceable measuring insert with mineral-insulated sheath (SS316L/1.4404)

Hazardous area approvals: flameproof (Ex d), intrinsically safe (Ex ia), non-sparking (Ex nA)

Cast aluminum or stainless steel terminal head, degree of protection IP67, NEMA 4x

 

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Thermocouple Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Thermocouple Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Thermocouple Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Thermocouple Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.