TMT84 temperature transmitterDiscontinued

TMT84 temperature transmitter
iTEMP TMT80, Head TransmitterDiscontinued
Configurable Models 3 models
Convert sensor signals into stable, standardized output signals suitable for all industries. Common spot models: TMT80-AA
Compare

Temperature transmitters

Measuring Principle Head transmitter
Input 1 x RTD, TC
Output 1 x analog 4...20 mA
Auxiliary power supply 8...35 V DC
Communication pc-programmable
Installation Terminal head form B
Accuracy (Pt100, -50...250 °C) <= 0,5 K
(Pt100, -58...482 °F) <= 0,9 °F
Galvanic isolation yes

This configurable temperature transmitter can be used with RTD and thermocouple sensors. The transmitter stores the linearization characteristics of various sensors, ensuring the highest level of measuring accuracy. The standard 4~20 mA current output signal is used for process measurement. It can be used in non-hazardous areas, providing fast, convenient and economical temperature measurement with reliable measured values.

 

Advantages

Two-wire technology with 4...20mA analog signal output

Fault signal on sensor open circuit or short circuit, with preset values in accordance with NAMUR NE 43

Meets electromagnetic compatibility (EMC) requirements in accordance with NAMUR NE 21.

Galvanic isolation, 500V (input/output)

User-configurable range setting

Spare Parts & Accessories 8

8 spare parts · click to collapse
Order codeDescription
TAF10-Remote junction box TAF10Application: E+H Head transmitter Housing: Alu IP66, 100x100x60mm.Enquire
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
51516983Communication interface FXA291Serial USB Computer Interface Technical Data: - USB Version1.1 or higher - Power supply via USB - IP51; NEMA/Typ 3 - Ambient temperature: -20....+60oC - Ex: II(2) G (EEx ia) II C - ATEX: BVS 05 ATEX E 095 Scope of deliovery: Commubox FXA 291 MS Windows USB driver Device is submitted for CSA/FM application. The device may not be modified and may be used with intrinsically safe circuits with corresponding characteristics only (see safety certificate).Details
TMT31-F+ Temperature transmitter TMT312-wire temperature transmitter. Single sensor input. Application: RTD/TC. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC, presetting failure current low. Consider additional marine certificate requirements on application side.Enquire
TMT71-Temperature transmitter TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.Enquire
71044062equipment package2x screws, 1x sealing CDI-connectorDetails
71044061equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connectorDetails
71528231DIN rail mounting accessoryClip according to IEC 60715 for temperature head transmitters. Packing unit: 2 piecesDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
3 models · click to collapse
All documents for this model
7 documents · click to expand
BA

操作手册 iTEMP® TMT80 Chinese

Rev. 1312 8 pages
Preview
BA

Operating instructions iTEMP® TMT80 English

Rev. 1418 12 pages
Preview
BA

Operating instructions iTEMP® TMT80 English

Rev. 0410 9 pages
Preview
TI

iTEMP TMT80 Chinese

Rev. 0621 8 pages
Preview
TI

通用型模块化温度变送器 Chinese

Rev. 0410 8 pages
Preview
TI

iTEMP TMT80 English

Rev. 0621 8 pages
Preview
TI

Technical Information iTEMP® TMT80 English

Rev. 0410 8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Temperature transmitter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was converting RTD or thermocouple signals into a standard current output.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing integral or remote versions by ambient, Ex zone and mounting.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing integral or remote versions by ambient, Ex zone and mounting, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — better noise immunity and much smaller transmission error, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Temperature transmitter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Temperature transmitter, focusing on converting RTD or thermocouple signals into a standard current output.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Temperature transmitter specification must therefore cover choosing integral or remote versions by ambient, Ex zone and mounting.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing integral or remote versions by ambient, Ex zone and mounting, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — better noise immunity and much smaller transmission error, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Temperature transmitter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Temperature transmitter; the focus is converting RTD or thermocouple signals into a standard current output.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing integral or remote versions by ambient, Ex zone and mounting.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing integral or remote versions by ambient, Ex zone and mounting, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means better noise immunity and much smaller transmission error, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Temperature transmitter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Temperature transmitter and the core task is converting RTD or thermocouple signals into a standard current output.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Temperature transmitter cannot be specified generically — it calls for choosing integral or remote versions by ambient, Ex zone and mounting.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing integral or remote versions by ambient, Ex zone and mounting, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is better noise immunity and much smaller transmission error.