TMT122 rail type temperature transmitterDiscontinued

TMT122 rail type temperature transmitter
iTEMP TMT122,Transmitter DINrail HARTDiscontinued
Configurable Models 3 models
Convert sensor signals into stable standardized output signals suitable for all industries
Compare

Temperature transmitters

Measuring Principle
Input 1 x RTD, TC, Ohm, mV
Output 1 x analog 4...20 mA
Auxiliary power supply 12...35 V DC (standard-version)
12...30 V DC (Ex-version)
Communication HART-protocol
Installation DIN rail
Accuracy (Pt100, -50...200 °C) <= 0,2 K
(Pt100, -58...392 °F) <= 0,4 °F
Galvanic isolation yes
Certification UL rec. Comp
marine approval
GOST Metrology
FM IS,NI,Class I,Div.1+2,Group ABCD
CSA IS,NI,Class I,Div.1+2,Group ABCD
ATEX II2(1)G Ex ia[ia Ga] IIC T6 Gb
ATEX II3G Ex nA IIC T6
FM+CSA IS,NI,Class I,Div.1+2,Group ABCD
CSA General Purpose
IECEx Ex ia IIC T6/T5/T4
NEPSI Ex nA IIC T4-T6

Superior reliability, accuracy and long-term stability in critical processes in all industries. The configurable transmitter not only digitally converts resistance thermometer (RTD) and thermocouple (TC) signals, but can also convert resistance and voltage signals via HART® communication. Commissioning tools installed on a personal computer enable fast, simple operation, display and maintenance. Mounted on a DIN rail complying with IEC 60715 (housing width: 22.5 mm).

 

Advantages

Universal configuration via HART® communication

High-precision measurement over the entire ambient temperature range

Fault signal on sensor wire break or short circuit, in accordance with NAMUR NE43

Meets EMC requirements in accordance with NAMUR NE21, CE approval

Explosion protection certificates: ATEX Ex, CSA IS, FM IS

Galvanic isolation

Complies with SIL2 approval

 

Application areas

The HART® communication temperature transmitter is used to convert different input signals into a 4...20 mA analog output signal

Input: resistance thermometer (RTD), thermocouple (TC), resistance (Ω) and voltage (mV)

HART® communication, operating front-end or panel devices using a handheld (DXR275, DXR375) or personal computer (e.g. ReadWin 2000 or FieldCare)

Spare Parts & Accessories 7

7 spare parts · click to collapse
Order codeDescription
51006248terminal blockTerminal plug-in 4pole SMSTB2,5 printedDetails
51006249terminal blockTerminal plug-in 4pole SMSTB2,5 printedDetails
51006250terminal blockTerminal plug-in 2pole RM5 printed -/+Details
51006251terminal blockTermin plug-in 2pole RM5 printed -/+Details
71402350Panel mounting accessoryfor RMA42x/RMx621/RTA421/RN221N/TMT12xDetails
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire
READWIN-Readwin 2000 Commissioning Package READWINReadwin 2000 Operation + Read. softwareEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
3 models · click to collapse
All documents for this model
9 documents · click to expand
BA

Operating manual iTEMP HART Communication English

HART Rev. 1102 58 pages
Preview
BA

Operating Manuals ReadWin 2000 (GB) English

Rev. 0110 124 pages
Preview
BA

BA155R Operating Instructions for TMT 122 Version 07.03 English

40 pages
Preview
BA

BA155R Operating Instructions for TMT 122 Version 07.03 English

36 pages
Preview
BA

ReadWin® Quick Setup English

15 pages
Preview
BA

Operating Manuals ReadWin 2000 (GB) English

64 pages
Preview
TI

技术资料 iTEMP® HART® TMT122 Chinese

HART Rev. 1310 12 pages
Preview
TI

iTEMP HART® TMT122 DIN rail English

HART Rev. 1419 8 pages
Preview
TI

iTEMP® TMT122 HART® DIN rail Technical information English

HART Rev. 1310 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Temperature transmitter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was converting RTD or thermocouple signals into a standard current output.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing integral or remote versions by ambient, Ex zone and mounting.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing integral or remote versions by ambient, Ex zone and mounting, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — better noise immunity and much smaller transmission error, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Temperature transmitter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Temperature transmitter, focusing on converting RTD or thermocouple signals into a standard current output.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Temperature transmitter specification must therefore cover choosing integral or remote versions by ambient, Ex zone and mounting.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing integral or remote versions by ambient, Ex zone and mounting, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — better noise immunity and much smaller transmission error, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Temperature transmitter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Temperature transmitter; the focus is converting RTD or thermocouple signals into a standard current output.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing integral or remote versions by ambient, Ex zone and mounting.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing integral or remote versions by ambient, Ex zone and mounting, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means better noise immunity and much smaller transmission error, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Temperature transmitter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Temperature transmitter and the core task is converting RTD or thermocouple signals into a standard current output.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Temperature transmitter cannot be specified generically — it calls for choosing integral or remote versions by ambient, Ex zone and mounting.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing integral or remote versions by ambient, Ex zone and mounting, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is better noise immunity and much smaller transmission error.