TMT142 on-site temperature transmitterDiscontinued

TMT142 on-site temperature transmitter
iTEMP TMT142, Field Transmitter HARTDiscontinued
Configurable Models 1 models
Convert sensor signals into stable, standard HART output signals for use in all industries
Compare

Temperature transmitters

Measuring Principle
Input 1 x RTD, TC, Ohm, mV
Output 1 x analog 4...20 mA
Auxiliary power supply 10,5...40 V DC (standard-version)
10,5...30 V DC (Ex-version)
Communication HART-protocol
Installation in field
Accuracy (Pt100, -50...200 °C) <=0,15 K
(Pt100, -58...392 °F) <=0,3 °F
Galvanic isolation yes
Certification UL rec. Comp
ATEX II1G Ex ia IIC T6
ATEX II2G Ex d IIC T6
ATEX II3G Ex nA IIC T6
ATEX IECEx II2D Ex tb IIIC Db
ATEX II1G Ex ia IIC T6, II2D Ex ia IIIC
FM IS, NI I/1+2/A-D
CSA IS, NI I/1+2/A-D
FM XP, NI, DIP I,II,III/1+2/A-G
CSA XP, NI, DIP I,II,III/1+2/A-G
CSA General Purpose
IECEx Ex ia IIC T6 Ga
IECEx Ex d IIC T6 Gb
NEPSI Ex ia IIC T4-T6
NEPSI Ex nA II T4-T6
NEPSI Ex d IIC T4-T6
EAC Ex ia IIC T6 Ga
EAC Ex d IIC T6 Gb
TIIS Ex ia IIC T4
TIIS Ex ia IIC T6
TIIS Ex d IIC T6

Unmatched reliability, accuracy and long-term stability in critical process applications in all industries. The configurable temperature transmitter not only transmits converted signals from RTD sensors and thermocouples, but also transmits resistance and voltage signals using HART® communication. It visualizes the signals on its own backlit display. The robust, durable housing is suitable for field use and can be connected directly in the process area. In addition, simple and fast operation and maintenance are possible via a PC using operating software.

 

Advantages

Rotatable backlit display

Operation, visualization and maintenance via PC using operating software such as FieldCare

Sensor monitoring: checks for faults and corrosion in accordance with NAMUR NE 89; checks for sensor wire break or short circuit in accordance with NAMUR NE 43

Optional stainless steel housing for EEx d applications

Approvals: ATEX (EEx ia, EEx d and dust ignition protection), FM, CSA (IS, NI, XP, DIP)

Galvanic isolation

Records min/max process values

Spare Parts & Accessories 20

20 spare parts · click to collapse
Order codeDescription
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
71310423Display housing fixing kit (3 pcs)Details
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
71158816O-ringDetails
71502617O-ring 88x3 HNBR 70° Shore PTFE_5pcsPacking unit: 5 piecesDetails
TMT142G-Housing TMT142GHousing TMT142GEnquire
51004948front cover latch pinScrew, washer, spring washerDetails
XPT0002-plug connectorEnquire
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
510043871/2 NPT to M20x1.5 adapterAdapter M20x1,5/NPT1/2" cable entryDetails
51004915M24x1.5 to M20x1.5 adapterAdapter M20x1.5 exter./M24x1.5 intern.VADetails
71502941O-Ring 18.77x1.78 HNBR 70° Shore PTFEPacking unit: 10 piecesDetails
51004490blind coverDetails
51006888blind coverDetails
71525620Blind plug M20x1.5 Ex-d + O-ring, aluminiumDetails
71525621Blind plug G1/2 Ex-d + o-ring, AluDetails
71525622Blind plug M20x1.5 Ex-d + O-ring V4ADetails
71525623Blind plug G1/2 Ex-d + O-ring V4ADetails
51007995mounting bracketMounting bracket SS316L, tube 1,5-3"Details
XPRFID-Spare RFID TAGConsists of: RFID TAG, fixing wire, crimp sleeve.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
1 models · click to collapse
All documents for this model
12 documents · click to expand
BA

BA iTEMP TMT142B Chinese

Rev. 1623 100 pages
Preview
BA

BA iTEMP TMT142B English

Rev. 1623 100 pages
Preview
BA

Operating Manuals ReadWin 2000 (GB) English

Rev. 0110 124 pages
Preview
BA

ReadWin® Quick Setup English

15 pages
Preview
BA

Operating Manuals ReadWin 2000 (GB) English

64 pages
Preview
BA

Operating instructions Temperature field transmitter iTEMP® HART® TMT142 English

HART 136 pages
Preview
TI

iTEMP TMT142B Chinese

Rev. 1621 24 pages
Preview
TI

温度变送器 Chinese

Rev. 1312 16 pages
Preview
TI

通用型温度变送器 Chinese

Rev. 0107 12 pages
Preview
TI

iTEMP TMT142B English

Rev. 1621 24 pages
Preview
TI

Technical Information iTEMP® HART® TMT142 English

HART Rev. 1312 14 pages
Preview
TI

Technical Information Temperature field transmitter iTEMP® HART® TMT142 English

HART 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Temperature transmitter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was converting RTD or thermocouple signals into a standard current output.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing integral or remote versions by ambient, Ex zone and mounting.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing integral or remote versions by ambient, Ex zone and mounting, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — better noise immunity and much smaller transmission error, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Temperature transmitter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Temperature transmitter, focusing on converting RTD or thermocouple signals into a standard current output.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Temperature transmitter specification must therefore cover choosing integral or remote versions by ambient, Ex zone and mounting.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing integral or remote versions by ambient, Ex zone and mounting, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — better noise immunity and much smaller transmission error, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Temperature transmitter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Temperature transmitter; the focus is converting RTD or thermocouple signals into a standard current output.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing integral or remote versions by ambient, Ex zone and mounting.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing integral or remote versions by ambient, Ex zone and mounting, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means better noise immunity and much smaller transmission error, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Temperature transmitter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Temperature transmitter and the core task is converting RTD or thermocouple signals into a standard current output.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Temperature transmitter cannot be specified generically — it calls for choosing integral or remote versions by ambient, Ex zone and mounting.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing integral or remote versions by ambient, Ex zone and mounting, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is better noise immunity and much smaller transmission error.