Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TR25 RTD ThermometerDiscontinued

TR25 RTD Thermometer
RTD Thermometer TR25Discontinued
The thermometer is mainly used in the chemical industry but also finds its use in other branches. The device with head transmitter is a complete unit ready for use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.
Compare

Thermometer

Measuring Principle
Characteristic / Application metric style
modular temperature assembly
threaded process connection
without neck
Thermowell / protection tube without (not intended to use with thermowell)
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 6,0 mm (0,24'')
Max. immersion length on request up to 10.000,00 mm (393,70'')
Material protection tube/ thermowell 1.4404 (316L)
Optional coating Not defined
Process connection male thread:
G1/4"
G1/2"
NPT1/4"
NPT1/2"
Tip shape straight
reduced
Surface roughness Ra Not defined
Operating temperature range PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F)
Max. process pressure (static) at 20 °C: 40 bar (580 psi)
Accuracy class A acc. to IEC 60751
class AA acc. to IEC 60751
Response time depending on configuration
t50 = 2 s
t90 = 5 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Certification Gost Metrology
SIL (transmitter only)

The thermometer is mainly used in the chemical industry and is also suitable for applications in other industries. Devices with a head-mounted transmitter are ready for immediate use and, compared with directly wired sensors, improve measurement accuracy and reliability. A wide range of process connections, dimensions and materials provide application flexibility.

 

Advantages

Modular design with a standard connection head compliant with DIN EN 50446 and customer-specific immersion length for high flexibility

High insert compatibility, designed to DIN 43772

Short tapered tip for faster response time

Easy selection of head transmitter: analog output 4 to 20 mA, HART®, PROFIBUS® PA or FF fieldbus

Spare Parts & Accessories 36

36 spare parts · click to collapse
Order codeDescription
52028179gasketProfile gasket for cover Stainless steel housing F15Details
60017971DisplayDisplay LC for TA20JDetails
71043745Atmospheric compensation filter portConsists of: filter plug plastic, Pressure compensation filter, O-ring. Usage: housing F15. Non Ex.Details
71090687Fieldbus connectorDetails
71009889***O-Ring 44,17x1,78 NBR70 labs free BlDetails
71044061equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connectorDetails
71367427gasketPacking unit: 10 piecesDetails
TA20A-*** Terminal Box TA20AProduct Phased Out. Connection head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: Aluminium epoxy resin coating Area temperature : max. +100oC; ATEX: +95oC.Enquire
TA20B-Terminal box TA20BConnecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material:Polyamid black Ambient temperature: max. +80 oC Protection: IP65Enquire
TA20D-Terminal Box TA20DProduct Phased Out. Connection head to mount a measuring insert with up to two head transmitters or a connection socket and one head transmitter. For mounting on armature or protection sleeve. Material: Aluminium, varnished Ambient temperature: max. +100 oC; ATEX: +95 oC. Protection: IP66Enquire
TA20J-Terminal Head TA20JStainless steel AISI 316L / W1.4404 Max temperature 100 oC; ATEX: +95 oC, protection class IP66/IP67Enquire
TA20R-Terminal box TA20RStainless steel AISI 316L W 1.4404. Max temperature 100 oC, ATEX: +95 oC. Protection class IP66/IP67Enquire
TA20W-Terminal Box TA20WProduct Phased Out. Connection head hinged to mount a measuring insert with head transmitter or connection socket. To be mounted on an armature or a protection sleeve. Material: Aluminium Area temperature: max. +100 oC; ATEX: +95 oC Protection: IP66Enquire
TA21E-Junction box TA21ERetainer for terminal block or head transmitter. Cover: srewable. Material: Aluminum. Max. temp.: +100 oC; ATEX +95 oC. Protection: IP65.Enquire
TMT180-*** module temperature transmitter TMT180Product Phased Out. Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.Enquire
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
READWIN-Readwin 2000 Commissioning Package READWINReadwin 2000 Operation + Read. softwareEnquire
TMT181-iTEMP TMT181, Head Transmitter PCPProduct being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.Enquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
FXA191-Commubox FXA191Modem to connect smart devices with INTENSOR or HART protocol to personal computers. The signal circuit is intrinsically safe (Ex i a). The connection to the personal computer is realized with the inte- grated cable through the serial port.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
All documents for this model
4 documents · click to expand
TI

技术资料 Omnigrad T TR25 Chinese

Rev. 0304 8 pages
Preview
TI

Omnigrad T TR25 技术资料 Chinese

Rev. 0113 16 pages
Preview
TI

Technical information English

Rev. 0304 12 pages
Preview
TI

Omnigrad T TR25 Technical Information English

Rev. 0113 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.