Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TR65 RTD Thermometer

TR65 RTD Thermometer
RTD Thermometer TR65
Configurable Models 3 models
The robust thermometer designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. The sensor may be used in direct contact without thermowell or where the application requires it, spring load inside of a separate thermowell. Flexible configuration possible.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
threaded process connection
without neck
Thermowell / protection tube without (not intended to use with thermowell)
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 3,0 mm (0,12'')
6,0 mm (0,24'')
Max. immersion length on request up to 30.000,00 mm (1.181,10'')
Material protection tube/ thermowell 1.4404 (316L)
Process connection male thread:
NPT1/2"
NPT3/4"
M20x1,5
compression fitting:
NPT1/2"
NPT3/4"
Tip shape straight
Surface roughness Ra Not defined
Operating temperature range PT100 TF iTHERM StrongSens:
-50 °C ...500 °C
(-58 °F ...932 °F)
PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 TF:
-50 °C ...400 °C
(-58 °F ...752 °F)
Max. process pressure (static) at 20 °C: 80 bar (1.160 psi)
Accuracy class A acc. to IEC 60751
class AA acc. to IEC 60751
Response time t50 = 2 s
t90 = 5 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX Ex ia, Ex d, Ex nA
IECEx Ex ia, Ex d, Ex tD
EAC Ex ia, Ex d
NEPSI Ex ia, Ex d
Explosion proof
Certification Gost Metrology
SIL (transmitter only)

This robust thermometer is suitable for harsh operating conditions and safety-critical measurement applications in the chemical, oil, gas and energy industries. An optional transmitter compatible with all common communication protocols is ready for immediate use and, compared with directly wired sensors, improves measurement accuracy and reliability. The sensor can be in direct contact with the medium or, depending on the measurement requirements, fitted with a spring-loaded thermowell for flexible configuration.

 

Advantages

Explosion protection types: intrinsically safe (Ex ia), flameproof (Ex d), non-sparking (Ex nA)

High measuring insert compatibility, designed to DIN 43772

Modular design with a standard connection head compliant with DIN EN 50446 and customer-specific insertion length for high flexibility

Spare Parts & Accessories 23

23 spare parts · click to collapse
Order codeDescription
TA30H-Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).Enquire
TA21H-Terminal head TA21HProduct Phased Out. Retainer for terminal block or head transmitter. Design: explosion proof. Cover: screwed. Ambient temp.: -40...100 oC (housing). Protection: IP66/68 (housing).Enquire
TA50-Mounting parts, compression fitting TA50Screw in.Enquire
71744221Spare part kit TA50-GB/NB/HB/PB/BB/CB/DBPacking unit: 10 pieces, d=6.1mm. Material: 316/1.4401.Details
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
TMT181-iTEMP TMT181, Head Transmitter PCPProduct being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.Enquire
TMT180-*** module temperature transmitter TMT180Product Phased Out. Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.Enquire
TMT182-*** module temperature transmitter TMT182Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, SIL2, galvanic isolation Fault reaction: NAMUR NE 43. Mounting: head form B, DIN43729. UL listed. GL (German Llyod) Marine.Enquire
TMT184-iTEMP TMT184, head transmitter PATemperature transmitter, Profibus-PA. Application: RTD, TC, Ohm, mV. Galvanic isolation. Profil V3.0. Curr. consumption 11mA Mounting: head form B, DIN43729.Enquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
TID10-Temperature transmitter display TID10to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84.Enquire
71044061equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connectorDetails
71660542Set Terminal Block 3-wire TS211Packing unit: 5 piecesDetails
71660543Set Terminal Block 4-wire TS211Packing unit: 5 piecesDetails
71660544Set Terminal Block 6-wire TS211Packing unit: 5 piecesDetails
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Measuring principle video

Click to play
3 models · click to collapse
All documents for this model
6 documents · click to expand
BA

BA iTHERM ModuLine工业温度计 Chinese

Rev. 0325 24 pages
Preview
BA

BA iTHERM ModuLine thermometer English

Rev. 0325 28 pages
Preview
TI

Omnigrad S TR65 Chinese

Rev. 0705 12 pages
Preview
TI

Omnigrad S TR65, TC65 技术资料 Chinese

Rev. 0216 16 pages
Preview
TI

Technical Information Omnigrad S TR65 English

Rev. 0705 10 pages
Preview
TI

Omnigrad S TR65, TC65 Technical Information English

Rev. 0216 20 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.