Thermometer TSM487, RTD
Technical Data
CompareThermometer
| Measuring Principle | |
| Characteristic / Application | metric style modular temperature assembly threaded process connection without neck transmitter included (fixed range) |
| Thermowell / protection tube | without (not intended to use with thermowell) |
| Insert / probe | mineral insulated (MI), flexible |
| Outer diameter protection tube / Insert | 6,0 mm (0,24'') |
| Max. immersion length on request | up to 250,00 mm (9,84'') |
| Material protection tube/ thermowell | 1.4404 (316L) |
| Process connection | male thread: G1/2" |
| Tip shape | straight |
| Surface roughness Ra | Not defined |
| Operating temperature range | PT 100: -30 °C ...200 °C (-22 °F ...392 °F) |
| Max. process pressure (static) | at 20 °C: 20 bar (290 psi) |
| Accuracy | class A acc. to IEC 60751 |
| Response time | t50 = 4 s t90 = 8 s |
| Integration head transmitter | yes (4 … 20 mA) |
Product Overview
This thermometer is mainly used in the chemical industry and also in other industries. The preferred application is temperature measurement in vessels and pipes without high process pressure and temperature. Compared with directly wired sensors, the integrated temperature transmitter enhances measuring accuracy and reliability. A wide range of versions for broad application.
-
Benefits
-
Modular design with a standard terminal head conforming to DIN EN 50446 and customer-specific immersion length for high flexibility
-
Highly compatible measuring element, designed in accordance with DIN 43772
-
Easy selection of the transmitter: analog output 4~20 mA, HART, PROFIBUS PA or FF fieldbus
Spare Parts & Accessories 2
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Manuals & Documents 1
All documents for this model1 documents · click to expand
Technical Information Easytemp® TSM487 English
Case Studies
Municipal Wastewater Treatment · thermistor — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
Configuration
Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.
Food & Beverage · thermistor — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
What We Did
We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · thermistor — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
Delivery Approach
Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.
Power & Energy · thermistor — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
Implementation
The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.
Related Products
Endress+HauseriTHERM ModuLine TM101
Endress+HauseriTHERM ModuLine TM131
Endress+HauserRTD Thermometer TR10
Endress+HauseriTHERM ModuLine TM111
Endress+HauseriTHERM CompactLine TM311
Endress+HauserCompact Thermometer TMR31
Endress+HauserThermometer, wire probe
Endress+Hauser