Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TST434B Indoor RTD thermometer

TST434B Indoor RTD thermometer
Indoor RTD thermometer
Endress+Hauser TST434B
Configurable Models 20 models
The iTHERM ModuLine TST434B RTD thermometer is specially designed for monitoring the room temperature in almost all industries. It is available as a complete unit including Endress+Hauser temperature transmitters for enhanced measurement accuracy and reliability compared to directly wired sensors. With a variety of common and advanced outputs and communication protocols, they offer easy customizing.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application probe for ambient temperature measurement
without neck
Thermowell / protection tube without (not intended to use with thermowell)
Outer diameter protection tube / Insert 20,0 mm (0,79'')
Material protection tube/ thermowell Aluminium
Operating temperature range PT 100:
-50 °C ...150 °C
(-58 °F ...302 °F)
Max. process pressure (static) at 20 °C: 1 bar (15 psi)
Accuracy class A acc. to IEC 60751
class B acc. to IEC 60751
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Certification SIL (transmitter only)

Field of application

The iTHERM ModuLine TST434B RTD thermometer is specially designed for monitoring room temperature in virtually all industries.
It is a complete unit including an Endress+Hauser temperature transmitter, offering increased measuring accuracy and reliability compared to directly wired sensors. Via various common and advanced output and communication protocols, they offer convenient customization.
Outdoor or indoor ambient temperature measurement
Maximum measuring range: -50 to +150°C (-58 to +302°F)
Degree of protection: IP66/68 (NEMA Type 4X housing)

 

Advantages
Robust terminal head complying with DIN EN 50446 or stable plastic housing provides optimum protection under extreme environmental conditions
Reliable, long-term stable and accurate indoor and outdoor ambient temperature measurement
Simple and fast wall mounting
Optional head transmitter: analog 4-20 mA, HART®, PROFIBUS®PA, FOUNDATION Fieldbus™, IO-Link, PROFINET® over Ethernet-APL/SPE

Spare Parts & Accessories 22

22 spare parts · click to collapse
Order codeDescription
TA30A-Terminal box TA30ARetainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
71182602Seal5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75Details
XPT0002-plug connectorEnquire
51004915M24x1.5 to M20x1.5 adapterAdapter M20x1.5 exter./M24x1.5 intern.VADetails
51006419cable glandEMC-screwed cable gland M20 for direct/ indirect shield earthing, cable 6,5-13mmDetails
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
TMT31-F+ Temperature transmitter TMT312-wire temperature transmitter. Single sensor input. Application: RTD/TC. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC, presetting failure current low. Consider additional marine certificate requirements on application side.Enquire
TMT36-F+ IO-Link Temperature Transmitter TMT362-wire temperature transmitter. Single sensor input. Application: RTD. Factory setup w/o additional specification: Pt100, 4-wire, oC. Mounting: head form B, DIN EN50446.Enquire
TMT71-Temperature transmitter TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.Enquire
TMT72-Temperature transmitter TMT722-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oCEnquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
TMT86-Temperature transmitter TMT862-wire Ethernet transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: CH1: Pt100, 4-wire, oC, CH2: inactive.Enquire
71044062equipment package2x screws, 1x sealing CDI-connectorDetails
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire
SFP20-FieldPort SFP20 USB/IO-Link modemIO-Link USB interface FieldPort SFP20 for commissioning and maintaining of IO- Link measuring devicesEnquire
71460208Dedicated M12 connector for FieldPort SFP20Cable to connect the FieldPort SFP20 with an IO-Link deviceDetails
71660542Set Terminal Block 3-wire TS211Packing unit: 5 piecesDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
144 models · click to collapse
All documents for this model
2 documents · click to expand
TI

TI iTHERM ModuLine TST434B Chinese

Rev. 0424 16 pages
Preview
TI

TI iTHERM ModuLine TST434B English

Rev. 0424 20 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.