2100Q Portable Turbidimeters

2100Q Portable Turbidimeters
2100Q Portable Turbidimeters
HACH 2100 Portable Turbs
Configurable Models 4 models
2100Q Portable Turbidimeters

产品概述

Easiest calibration and verification with accurate results every time.

Effortlessly achieve accurate turbidity measurement with the Hach 2100Q Portable Turbidimeter, trusted for consistent performance in industrial and municipal water systems. This lightweight, portable device is designed for field operators ensuring water quality across essential points in your treatment process. Whether you’re monitoring municipal water supplies, industrial outputs, or adhering to EPA turbidity compliance, the 2100Q delivers reliable results backed by stringent standards.

Engineered to meet EPA Method 180.1 standards, the 2100Q ensures your turbidity measurements are fully aligned with regulatory requirements, offering peace of mind and precision. Measurements are in Nephelometric Turbidity Units (NTU), ensuring data compatibility with standards recognized by U.S. environmental regulators. Its intuitive interface streamlines the calibration and verification process, allowing you to quickly transition from setup to data collection.With its robust design and proven accuracy, this portable turbidimeter is the tool you need for efficient, accurate turbidity testing.

Be confident in your water quality testing with the Hach 2100Q Portable Turbidimeter, a dependable choice for achieving regulatory compliance while maintaining operational efficiency in the lab, field, or plant.

Simplify your water quality testing process. Order yours today and experience accuracy and efficiency like never before.

主要特点

  • Easy on-screen assisted calibration and verification:Save time and get accurate results with an easy-to-follow interface that eliminates the need for complicated manuals to perform routine calibrations. Single-standard Rapidcal™ calibration offers a simplified solution for low level measurements, while ensuring you meet reporting requirements.
  • Simple data transfer:Data transfer with the optional USB+Power Module is simple, flexible, and doesn't require additional software. All data can be transferred to the module in XML format and easily downloaded to your computer with a USB connection, providing superior data integrity and availability.
  • Accurate for rapidly settling samples:The innovative Rapidly Settling Turbidity™ mode provides accurate measurements for difficult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.
  • Convenient data logging:Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages, and the result.
  • Optical system for precision in the field:The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, enabling analysts to achieve laboratory-grade performance on a wide range of samples, even under difficult site conditions.

技术参数

参数名称说明
Accuracy± 2 % of reading plus stray light
Battery Requirements4, AA
CertificationsCE certified
Compliance CertificationsCE/WEEE
Data Logging500 records
Dimensions (H x W x D)77 mm x 107 mm x 229 mm
Display Size240 x 160 pixels
Display TypeGraphic LCD
Enclosure RatingIP67
InterfaceNo USB and Power Cord
Light SourceTungsten Filament Lamp
Manual LanguagesEnglish, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
Max. operating humidity90
Measurement MethodRatio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal
Measurement ModesNormal (Push to Read), Signal Averaging, Rapidly Settling Turbidity
Operating Temperature Range0 - 50 °C (32 - 122 °F)
Power Requirements100 - 240 V AC / 50/60 Hz (with optional Power or USB+Power module)
Power SupplyBatteries (see Battery Requirements) or Optional Power Supply
Range0 - 1000 NTU
Reading ModesNormal (Push to Read) Signal Averaging Rapidly Setting Turbidity
RegulatoryEPA Method 180.1
Repeatability± 1 % of reading or 0.01 NTU , whichever is greater
Response Time6 s in normal reading mode
Sample Cell Compatibility25 mm x 60 mm round
Sample Volume15 mL
Signal AveragingSelectable on/off
Storage Conditions-40 - 60 °C (-40 - 140 °F)
Stray Light< 0.02 NTU
UnitsNTU
User InterfaceButton Graphic User Interface
User Interface LanguagesEnglish, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
Warranty12 months
Weight0.53 kg (1.2 lbs) without batteries
What's included?Instrument, case assembly, 4 AA alkaline batteries, 6 sample cells, Stablcal ampule kit, silicone oil, oiling cloth, manual.

应用领域

Groundwater · Municipal Water · QA/QC Lab · Surface Water

同系列其他配置

型号
2100QIS012100Q IS Portable Turbidimeter (LED), 0-1000 FNU
2100Q01USB2100Q Portable Turbidimeter Kit (EPA), 0-1000 NTU, with USB and Power
2100QIS01USB2100Q IS Portable Turbidimeter (LED), 0-1000 FNU, with USB and Power M

资料下载

4 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hach-lab — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hach-lab — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hach-lab — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hach-lab — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.

Implementation

The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.