Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

4790100Discontinued

4790100
2100AN IS Laboratory Turbidimeter, ISO, 115 VacDiscontinued
HACH 4790100
Hach has a long history in leadership in turbidity measurement and has consistently provided reliable lasting laboratory turbidity meters. In the spirit of innovation and continuous improvement, Hach

产品概述

Hach has a long history in leadership in turbidity measurement and has consistently provided reliable lasting laboratory turbidity meters. In the spirit of innovation and continuous improvement, Hach has discontinued its legacy 2100N, 2100AN, 2100N IS, and 2100AN IS series laboratory turbidimeters and refreshed its portfolio with two new laboratory turbidity meters.

The legacy lab turbidimeters have been replaced with the TU5200 and TL23 series turbidimeters.

The TU5200 laboratory turbidimeter employs a groundbreaking 360° x 90° Detection technology, developed specifically for the low turbidity drinking water applications. The TU5200 is also part of the TU5 Series, which combines a laboratory and online turbidimeters with identical technology that delivers matching turbidity results from both the online and laboratory readings. For more information on TU5200, please go to hach.com/p-tu5200-benchtoplaser-turbidimeter/LPV442.99.01012

The TL23 Series laboratory turbidimeters employ the same trusted optic block as the legacy 2100N/AN making it an ideal replacement for industrial and other high turbidity applications. The TL23 also has an updated and intuitive user interface similar to that of the rest of Hach's laboratory instruments. For more information on TL23, please go to hach.com/p-tl23-series-laboratory-turbidimeters/LPV444.99.00210

For an overview and comparison of TU5200 and TL23, Hach's new laboratory turbidimeters, please go to hach.com/products/instrument-type/turbidimeter

技术参数

参数名称说明
Accuracy± 2 % of reading or ± 0.01 NTU from 0 - 1000 NTU ± 5 % of reading from 1000 - 4000 NTU ± 10 % of reading from 4000 - 10,000 NTU
Air Purge0.1 scfm at 69 kPa , hose barb connection for 1/8 in tubing, maximum 138 kPa. Dry nitrogen or instrument-grade air.
Compliance CertificationsUL/CSA
Dimensions (H x W x D)156 mm x 400 mm x 305 mm
Display Type8-digit LED display
IncludesInstrument, sample cells, Stablcal calibration standards, silicone oil, oiling cloth, dust cover, manual, power cord with NA plug, printer paper
InterfaceRS232 serial (bi-directional)
Lamp Type870 ± 30 nm LED
Manual LanguagesEnglish
Max. operating humidity90
Measurement ModesFNU, FAU, NTU, EBC, ABS, %T, ASC
Operating Temperature Range0 - 40 °C
Power Options115 V AC with US power cord
Power Requirements115 - 230 VAC; 50 to 60 Hz; 60 VA maximum
PrinterBuilt-in (thermal, 58 mm, up to 28 column)
RangeRatio On: Manual 0 - 10000 ; Auto 0 - 10,000 auto decimal; Ratio Off: 0 - 40.0
Range0 - 10000 FNU
RegulatoryISO 7027
Repeatability± 1 % of reading or ± 0.01 FNU, whichever is greater
Response Time6.8 s with signal averaging off 14 s with signal averaging on
Sample Cell Compatibility25 mm round; 12, 13, 16, and 19 mm round with optional adapter kit
Sample Volume20 mL with 25 mm sample cell 2.5 mL with 12 mm 3.5 mL with 13 mml 5 mL with 16 mml 7 mL with 19 mm
Serial input interfaceRS232 serial interface (bidirectional)
Source LampLED lamp
Stabilization TimeInstantaneous
Storage Conditions-40 °C to 60 °C
User InterfaceButton
User Interface LanguagesEnglish
User Programs2
Weight3.77 kg
What's included?Instrument, sample cells, Stablcal calibration standards in sealed vials, silicone oil, oiling cloth, dust cover, manual, power cord with NA plug, printer paper.

应用领域

Groundwater · Municipal Water · Surface Water

资料下载

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hach-lab — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hach-lab — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hach-lab — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hach-lab — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.

Implementation

The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.