HQ30D Single Input Digital Multi Parameter Analyzer

HQ30D Single Input Digital Multi Parameter Analyzer
Single-input digital multi-parameter analyzer
HACH HQ30D
HQ30D Single Input Digital Multi-parameter Analyzer

HQ30d single-input multi-parameter digital analyzer is a plug-and-play analyzer suitable for any IntelliCAL electrode. An analyzer can measure pH, conductivity and LDO; The electrode serial number can be automatically registered in the analyzer. Both the sample ID and the operator ID can be linked to the measurement and stored in the recorder for final traceability. The replacement of measurement parameters/electrodes is fast and convenient without recalibration. The factory calibrated IntelliCAL electrode can be used directly. The password protection function of data can ensure accurate and tamper-free reports; A 500 data logging function stores measurement results, calibrations and inspection standards.

technical parameters:

  • power supply: 4AA batteries; battery life:>200 hours, with AC/DC power connection

  • Single parameter display: can display readings from 1 electrode.

  • pH electrode: pH,mV, temperature

  • Conductivity electrode: selected parameters, temperature correction and temperature

  • LDO electrode: dissolved oxygen, pressure, temperature

  • Data Memory: 500 sets of data

  • Data storage: The calibration data is stored in a log. Automatic storage in "press-and-read" mode and interval measurement mode. In the "Lian

  • Manual storage is required for continuous reading mode.

  • Temperature correction/compensation: automatic Data logging: user selection interval

  • Lock display function: continuous measurement mode or press-and-read measurement mode has the function of averaging LDO measurement readings.

  • Automatic identification of pH buffers: Three options are available:

  • pH automatic identification function: can identify the pH of 4,7,10 standard solution

  • IUPAC: 1.679,4.005,7.000,10.012

  • DIN: 1.09,4.65,9.23

  • Water resistance: the tester shell can be soaked in water at a depth of 1 meter for 30 minutes (IP67)

Ordering Information:

  • HQ30d53000000 HQ30d Single Input Multi-parameter Digital Analyzer Host

  • HQ30d5330100 HQ30d host, standard LDO dissolved oxygen probe, 1m cable

  • HQ30d5330300 HQ30d host, standard LDO dissolved oxygen probe, 3m cable

  • 8505100 HQ30d host, shock-resistant LDO dissolved oxygen probe, 5m cable

  • HQ30d53101000 HQ30d host, pHC10101 standard pH electrode, 1m cable

  • HQ30d53103000 HQ30d host, pHC10103 standard pH electrode, 3m cable

  • HQ30d53115000 HQ30d host, pHC10105 impact-resistant pH electrode, 5m cable

  • HQ30d53201000 HQ30d host, CDC40101 standard conductivity electrode, 1m cable

  • HQ30d53203000 HQ30d host, CDC40103 standard conductivity electrode, 3m cable

  • HQ30d53215000 HQ30d host, CDC40105 impact-resistant conductivity electrode, 5m cable

  • HQ30d53101201 HQ30d mainframe, PHC10103 standard pH electrode (1 m cable),CDC40103 standard conductivity electrode (1 m cable)

  • HQ30d53103203 HQ30d host, PHC10103 standard pH electrode (3 m cable),CDC40103 standard conductivity electrode (3 m cable)

  • HQ30d53101301 HQ30d mainframe, PHC10103 standard pH electrode (1 m cable),LDO10101 standard dissolved oxygen electrode (1 m cable)

  • HQ30d53103303 HQ30d host, PHC10103 standard pH electrode (3 m cable),LDO10103 standard conductivity electrode (3 m cable)

  • HQ30d53201301 HQ30d host, CDC40101 standard conductivity electrode (1 m cable),LDO10101 standard dissolved oxygen electrode (1 m cable)

  • HQ30d53203303 HQ30d host, CDC40103 standard conductivity electrode (3 m cable),LDO10103 standard conductivity electrode (3 m cable)

  • 8506300 HQ30d basic dissolved oxygen kit, including HQ30d main unit, LDO10101 dissolved oxygen sensor, pedestal

  • 5825800 carrying case: can hold 2 shock-resistant sensors, one HQ30d or HQ40d main, 5 120 beakers

  • 5189900 low ion concentration flow cell

  • 8506600 hash intelliCAL probe holder (except LBOD electrode)

pH electrode

  • Ultra Liquid-Filled Standard Composite Electrode: pHC28101(1 m cable), pHC28103(3 m cable)

  • Gel standard composite electrode: pHC10101(1 m cable), pHC10103(3 m cable)

  • Gel rugged composite electrodes: pHC10105(5 m cable), pHC10110(10 m cable), pHC10115(15 m), pHC10130(30 m)

  • Liquid-filled standard composite electrode: pHC30101(1 m cable), pHC30103(3 m cable)

ORP electrode

  • Gel standard composite electrode: MTC10101(1 m), MTC10103(3 m)

  • Gel rugged composite electrodes: MTC10105(5 m), MTC10110(10 m), MTC10115(15 m), MTC10130(30 m)

  • Liquid-filled standard composite electrode: MTC30101(1 m cable), MTC30103(3 m cable)

conductivity electrode

  • Standard electrode: CDC40101(1 m cable), CDC40103(3 m cable)

  • Routine electrodes: CDC40105(5 m), CDC40110(10 m), CDC40115(15 m), CDC40130(30 m)

  • dissolved oxygen electrode

  • Standard electrode: LDO10101(1 m cable), LDO10103(3 m cable)

  • rugged electrodes: LDO10105(5 m cable), LDO10110(10 m cable), LDO10115(15 m), LDO10130(30 m)

  • ISE ion-selective electrode

  • Sodium ion selective electrode: ISENa38101(1 m cable), ISENa38103(3 m cable)

  • Ammonia nitrogen electrode: ISENH318101(1 m), ISENH318103(3 m), ISENH418101(1 m), ISENH418103(3 m)

  • Chloride electrode: ISECl18101(1 m cable), ISECl18103(3 m cable)

  • Fluoride ion electrode: ISEF12101(1 m cable), ISEF12103(3 m cable)

  • Nitrate electrode: ISENO318101(1 m cable), ISENO318103(3 m cable)

Municipal Wastewater Treatment

Municipal Wastewater Treatment · multiparameter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from multiparameter, focusing on monitoring several water parameters at one measuring point.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The multiparameter specification must therefore cover configured by parameter set, mounting and cleaning needs.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on configured by parameter set, mounting and cleaning needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — one point replacing several single-parameter units, saving capex and upkeep, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · multiparameter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is multiparameter; the focus is monitoring several water parameters at one measuring point.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with configured by parameter set, mounting and cleaning needs.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on configured by parameter set, mounting and cleaning needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means one point replacing several single-parameter units, saving capex and upkeep, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · multiparameter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on multiparameter and the core task is monitoring several water parameters at one measuring point.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So multiparameter cannot be specified generically — it calls for configured by parameter set, mounting and cleaning needs.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves configured by parameter set, mounting and cleaning needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is one point replacing several single-parameter units, saving capex and upkeep.

Power & Energy

Power & Energy · multiparameter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted multiparameter properly configured on the existing plant, with the aim of monitoring several water parameters at one measuring point.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the multiparameter configuration has to involve configured by parameter set, mounting and cleaning needs.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant configured by parameter set, mounting and cleaning needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is one point replacing several single-parameter units, saving capex and upkeep, and the readings are now used for process tuning.