HQ430ddesktop single input digital multi-parameter analyzer
-
American Hash HQ430d laboratory measuring instrument is specially designed for water quality testing and is an advanced laboratory measuring instrument. HQD meters connect to IntelliCAL probes to automatically identify measurement parameters, calibration history data, and method settings to minimize errors and setup time.
-
The laboratory measuring instrument has a large backlit display, which can measure important water quality parameters and improve labor productivity.
-
All HQd gauges offer an intuitive user interface for simple operation and precise measurements.
-
IntelliCAL the calibration data stored in the smart probe to ensure reliable measurement data.
-
Standard: host, 4 AA batteries, power adapter, quick operation instructions, user manual.
HQ430d desktop single input digital multi-parameter analyzer technical parameters
-
Automatic Buffer Recognition: Color Recognition: 4.01,7.00,10.01pH
-
IUPAC:1.6794.005,7.000,10.012,12.45
-
DIN:1.09,4.65,9.323
-
user-defined buffer
-
BOD5/CBOD calculation: Built-in WIMS BOD management software
-
calibration data storage: calibration summary data recording and display
-
calibration interval/alarm/reminder: 2 hours to 7 days
-
compatibility: CE,WEEE
-
conductivity accuracy: ± 0.5%
-
conductivity range: 0.01 μS/cm-200mS/cm
-
conductivity resolution: 0.01 μS/cm
-
user calibration solution: user-defined standard set
-
user calibration standard: user-defined standard group
-
Dissolved oxygen range: 0.01-20mg/L
-
oxygen saturation range: 0-200%
-
dissolved oxygen resolution: 0.01mg/L
-
data output: USB interface to download to PC or flash disk, automatically transfer the entire data record or reading
-
data memory: 500 pieces
-
Data storage: GLP/ISO-compliant readings are stored with calibration details, calibration details and inspection standard readings are stored in data records,
-
key automatic storage mode and time interval measurement mode. Continuous manual storage mode
-
digital probe input: 1 way
-
size weight: 89 mmx173mmx234mm,0.85Kg
-
display: display pH reading or ORP reading
-
pH Measurement: pH,mV, Temperature
-
ORP/Redox Potential: mV, Temperature
-
conductivity: conductivity, total dissolved solids TDS, salinity, resistivity, temperature
-
LDO Dissolved Oxygen: Dissolved Oxygen, Oxygen Partial Pressure, Temperature
-
LBOD: Dissolved Oxygen, Partial Pressure of Oxygen, Temperature
-
sodium ion: sodium, mV, temperature
-
display lock function: continuous reading or key reading mode, can be used for LDO measurement average function
-
Display Type
-
display: 240*160pixel
-
pH:pH,mV, temperature Conductivity: Conductivity, Resistivity, Salinity, Total Dissolved Solids, Temperature
-
LDO: dissolved oxygen, partial pressure of oxygen, temperature
-
ORP/Redox Potential: mV, Temperature
-
sodium ion: sodium, mV, temperature
-
Fixation buffer selection: IUPAC standard, DIN19266, technical buffer (DIN19267) or 4-7-10 buffer, or user-defined buffer
-
IP protection level: IP54
-
ISE Direct Measurement: Yes
-
ISE electrode calibration: electrode specifications-see user guide
-
sensor input: M12 digital interface for IntelliCAL probe
-
Interface Languages: English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Swiss, Czech, Russian
-
internal data storage: 500
-
ORP Electrode Calibration: Predefined ORP Standards
-
ORP Range:-1500-+ 1500mV
-
pH range: 0-14pH
-
ORP accuracy: ± 0.1mV
-
pH accuracy: ± 0.002pH
-
ORP Resolution: 0.1mV
-
pH Resolution: 0.001pH,0.01pH,0.1pH Relative Humidity: 90% RH, No Condensation
-
working temperature: 5-45 ℃
-
operation error message: full text message
-
operation interface: button
-
data interface: USB, PC/flash disk
parameters:pH,mV,ORP/redox potential, dissolved oxygen, conductivity, total dissolved solids TDS, salinity, resistivity, temperature
Salinity Resolution: 0.01ppt Temperature Compensation: Off, Automatic, Manual
HQ430d Desktop Single Input Digital Multi-Parameter Analyzer Ordering Guide
-
HQ430d standard includes: host, 4 AA batteries, power adapter, quick operation instructions, user manual.
-
8509600:HQ430d basic conductivity kit, including HQ430d host, CDC40101 conductivity electrode, electrode holder, standard solution
-
8509601:HQ430d basic dissolved oxygen kit, including HQ430d host, LDO10101 dissolved oxygen electrode, electrode holder, operation manual, etc.
-
8509698:HQ430d complete laboratory kit, including HQ430d host, PHC10101 pH electrode, MTC10101 ORP electrode, LDO10101 dissolved oxygen electrode, CDC40101 conductivity electrode, pH standard solution, pH preservation solution, ORP standard solution, conductivity standard solution, electrode holder, and operation guidance
-
8509699:HQ430d pure water laboratory kit, including HQ430d host, pHC28101 pH electrode, LDO10101 dissolved oxygen electrode, CDC40101 conductivity electrode, pH standard solution, pH preservation solution, conductivity standard solution, electrode holder, and operation guidance
-
5189900: low ion concentration flow cell
-
8506600: Hash intelliCAL probe holder (except LBOD electrode)
pH electrode
-
Ultra Liquid-Filled Standard Composite Electrode: pHC28101(1 m), pHC28103(3 m)
-
gel standard composite electrode: pHC10101(1 m), pHC10103(3 m)
-
gel rugged composite electrode: pHC10105(5 m), pHC10110(10 m), pHC10115(15 m), pHC10130(30 m)
-
liquid-filled standard composite electrode: pHC30101(1 m), pHC30103(3 m)
ORP electrode
-
gel standard composite electrode: MTC10101(1 m), MTC10103(3 m)
-
gel rugged composite electrode: MTC10105(5 m), MTC10110(10 m), MTC10115(15 m), MTC10130(30 m)
-
liquid-filled standard composite electrode: MTC30101(1 m), MTC30103(3 m)
conductivity electrode
-
standard electrode: CDC40101(1 m), CDC40103(3 m)
-
rugged electrodes: CDC40105(5 m), CDC40110(10 m), CDC40115(15 m), CDC40130(30 m)
dissolved oxygen electrode
-
standard electrode: LDO10101(1 m), LDO10103(3 m)
-
rugged electrodes: LDO10105(5 m), LDO10110(10 m), LDO10115(15 m), LDO10130(30 m)
ISE ion-selective electrode
-
sodium ion selective electrode: ISENa38101(1 m), ISENa38103(3 m)
-
ammonia nitrogen electrode: ISENH318101(1 m), ISENH318103(3 m), ISENH418101(1 m), ISENH418103(3 m)
-
chloride electrode: ISECl18101(1 m), ISECl18103(3 m)
-
fluoride electrode: ISEF12101(1 m), ISEF12103(3 m)
-
nitrate electrode: ISENO318101(1 m), ISENO318103(3 m)
Case Studies
Municipal Wastewater Treatment · multiparameter — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from multiparameter, focusing on monitoring several water parameters at one measuring point.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The multiparameter specification must therefore cover configured by parameter set, mounting and cleaning needs.
Delivery Approach
Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on configured by parameter set, mounting and cleaning needs, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — one point replacing several single-parameter units, saving capex and upkeep, with confidence in this measuring point improving markedly.
Food & Beverage · multiparameter — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is multiparameter; the focus is monitoring several water parameters at one measuring point.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with configured by parameter set, mounting and cleaning needs.
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on configured by parameter set, mounting and cleaning needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means one point replacing several single-parameter units, saving capex and upkeep, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · multiparameter — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on multiparameter and the core task is monitoring several water parameters at one measuring point.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So multiparameter cannot be specified generically — it calls for configured by parameter set, mounting and cleaning needs.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves configured by parameter set, mounting and cleaning needs, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is one point replacing several single-parameter units, saving capex and upkeep.
Power & Energy · multiparameter — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted multiparameter properly configured on the existing plant, with the aim of monitoring several water parameters at one measuring point.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the multiparameter configuration has to involve configured by parameter set, mounting and cleaning needs.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant configured by parameter set, mounting and cleaning needs, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is one point replacing several single-parameter units, saving capex and upkeep, and the readings are now used for process tuning.