IntelliCALⓇ ISEF121 is a digital, combination, Fluoride ion selective electrode (ISE) with a with a non-refillable gel reference with a single junction porous PTFE annular ring, and built-in temperature sensor. The electrode measures fluoride concentration in water samples. The laboratory version of this ISE is shockproff with its Epoxy plastic body.The IntelliCAL ISEF121 probe is available with a 1 or 3 meter cable and is intended for laboratory use. The ISEF181’s solid-state sensor design eliminates membrane replacement and allows for dry storage of the ISE. The ISEF121 is ideal for measuring fluoride concentrations in wastewater, drinking water and general water quality applications.
主要特点
- Requires virtually no maintenance:The solid-state sensor design allows for DRY storage of the ISE without a shelf life. Also, the probe does not require the electrolyte to be refilled or membrane replacement.
- Fast, stable, and accurate results:IntelliCAL digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large annular reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability.
- Ultimate traceability in measurement history:Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
- Can be moved between meters without the need to re-calibrate or re-enter measurement settings:Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ±0.02 mV or 0.05%, whichever is greater |
| Cable Length | 3 m (9.84 ft) |
| Electrode Type | Non-Refillable Dritek Gel Reference Element |
| ISA Required | Fluoride ISA (#258999) |
| Junction | Annular Junction (PTFE) |
| Kit? | No |
| Length | 175 mm (6.89 in.) |
| Method Type | Field: Non-Refillable Dritek Gel Reference Element |
| Parameter | Fluoride |
| Probe Type | Standard |
| Product Kit | Model: ISEF121 Accessories Included: None |
| Range | 0.01 mg/L (5 x 10-7 M) - 19 g/L (1 M) F⁻ |
| Reference Type | Ag/AgCl |
| Resolution | Selectable up to 4 significant digits |
| Sample depth | 25.4 mm (1 in.) |
| Sample Volume | 25 mL |
| Sensor material | Epoxy |
| Sensor Type | Solid-state crystal membrane |
| Special Features | Dry storage & fast response time. No replacement membranes. |
| Temperature Accuracy | ±0.3 °C (±0.54 °F) |
| Temperature Range | 5 - 50 °C (41 - 122 °F) |
| Temperature Resolution | 0.1 °C (0.18 °F) |
| Test requirements | Parameter Needed: Fluoride Minimum Sample Depth (mm): 26 |
| Thermistor | ATC |
| Warranty | 12 months |
| Weight | 0.15 kg |
| What's included? | IntelliCAL ISEF121 combination Fluoride ISE, 3 m cable (ISEF12101), Test certificate, and Basic User Manual. |
应用领域
Municipal Water · Potable Water · Production Water · Surface Water
同系列其他配置
| 型号 | |
|---|---|
| ISENH418101 | IntelliCAL ISENH4181 Ammonium (NH₄⁺) Ion Selective Electrode (ISE), 1 |
| ISENH418103 | IntelliCAL ISENH4181 Ammonium (NH₄⁺) Ion Selective Electrode (ISE), 3 |
| ISENO318101 | IntelliCAL ISENO3181 Nitrate (NO₃⁻) Ion Selective Electrode (ISE), 1 m |
| ISENO318103 | IntelliCAL ISENO3181 Nitrate (NO₃⁻) Ion Selective Electrode (ISE), 3 m |
| ISENH4181AP | IntelliCAL ISENH418101 Ammonium (NH₄⁺) Ion Selective Electrode (ISE) w |
| ISENO3181AP | IntelliCAL ISENO318101 Nitrate (NO₃⁻) Ion Selective Electrode (ISE) wi |
| ISENA38103 | IntelliCAL ISENA381 Sodium (Na⁺) Ion Selective Electrode (ISE), 3 m ca |
| ISENA38101 | IntelliCAL ISENA381 Sodium (Na⁺) Ion Selective Electrode (ISE), 1 m ca |
| ISENH318103 | IntelliCAL ISENH3181 Ammonia (NH₃) Ion Selective Electrode (ISE), 3 m |
| ISENH318101 | IntelliCAL ISENH3181 Ammonia (NH₃) Ion Selective Electrode (ISE), 1 m |
| ISECL18101 | IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 1 m |
| ISECL18103 | IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 3 m |
| ISEF12101 | IntelliCAL ISEF121 Fluoride (F⁻) Ion Selective Electrode (ISE), 1 m ca |
| ISENH3181AP | IntelliCAL ISENH318101 Ammonia (NH₃) Ion Selective Electrode (ISE) wit |
| ISECL181AP | IntelliCAL ISECL18101 Chloride (Cl⁻) Ion Selective Electrode (ISE) wit |
| ISEF121AP | IntelliCAL ISEF12101 Fluoride (F⁻) Ion Selective Electrode (ISE) with |
| ISENA381AP | IntelliCAL ISENA38101 Sodium (Na⁺) Ion Selective Electrode (ISE) with |
资料下载
- Introduction to Ion-Selective Measurement
- Electrochemistry Theory and Practice
- Introduction to Hach Services
- A melhor solução para resultados precisos em todas as aplicações
- Una sólución prfec para obtener resultados precisos en todas las aplicaciones
- โซลูชันที่ มอบผลลัพธ์ที่ แม่นยำสูงสุด สำหรับทุกการใช้งาน
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
Case Studies
Municipal Wastewater Treatment · Hach-lab — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.
Configuration
Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.
Food & Beverage · Hach-lab — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.
What We Did
We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hach-lab — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.
Delivery Approach
Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.
Power & Energy · Hach-lab — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.
Implementation
The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.
Related Products
HACHDigester (rapid COD digester)
HACHMulti-channel electrochemical analyzer
HACHPro/Pro+ pocket water tester
HACHWater quality analysis test strip series
HACHLiquid colorimeter
HACHPortable water toxicity analyzer
HACHSpecial Service / Others TSS
HACH