HACH IntelliCAL
Configurable Models 18 models
IntelliCAL ISE Probes

产品概述

IntelliCALⓇ ISEF121 is a digital, combination, Fluoride ion selective electrode (ISE) with a with a non-refillable gel reference with a single junction porous PTFE annular ring, and built-in temperature sensor. The electrode measures fluoride concentration in water samples. The laboratory version of this ISE is shockproff with its Epoxy plastic body.The IntelliCAL ISEF121 probe is available with a 1 or 3 meter cable and is intended for laboratory use. The ISEF181’s solid-state sensor design eliminates membrane replacement and allows for dry storage of the ISE. The ISEF121 is ideal for measuring fluoride concentrations in wastewater, drinking water and general water quality applications.

主要特点

  • Requires virtually no maintenance:The solid-state sensor design allows for DRY storage of the ISE without a shelf life. Also, the probe does not require the electrolyte to be refilled or membrane replacement.
  • Fast, stable, and accurate results:IntelliCAL digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large annular reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability.
  • Ultimate traceability in measurement history:Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
  • Can be moved between meters without the need to re-calibrate or re-enter measurement settings:Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters

技术参数

参数名称说明
Accuracy±0.02 mV or 0.05%, whichever is greater
Cable Length3 m (9.84 ft)
Electrode TypeNon-Refillable Dritek Gel Reference Element
ISA RequiredFluoride ISA (#258999)
JunctionAnnular Junction (PTFE)
Kit?No
Length175 mm (6.89 in.)
Method TypeField: Non-Refillable Dritek Gel Reference Element
ParameterFluoride
Probe TypeStandard
Product KitModel: ISEF121 Accessories Included: None
Range0.01 mg/L (5 x 10-7 M) - 19 g/L (1 M) F⁻
Reference TypeAg/AgCl
ResolutionSelectable up to 4 significant digits
Sample depth25.4 mm (1 in.)
Sample Volume25 mL
Sensor materialEpoxy
Sensor TypeSolid-state crystal membrane
Special FeaturesDry storage & fast response time. No replacement membranes.
Temperature Accuracy±0.3 °C (±0.54 °F)
Temperature Range5 - 50 °C (41 - 122 °F)
Temperature Resolution0.1 °C (0.18 °F)
Test requirementsParameter Needed: Fluoride Minimum Sample Depth (mm): 26
ThermistorATC
Warranty12 months
Weight0.15 kg
What's included?IntelliCAL ISEF121 combination Fluoride ISE, 3 m cable (ISEF12101), Test certificate, and Basic User Manual.

应用领域

Municipal Water · Potable Water · Production Water · Surface Water

同系列其他配置

型号
ISENH418101IntelliCAL ISENH4181 Ammonium (NH₄⁺) Ion Selective Electrode (ISE), 1
ISENH418103IntelliCAL ISENH4181 Ammonium (NH₄⁺) Ion Selective Electrode (ISE), 3
ISENO318101IntelliCAL ISENO3181 Nitrate (NO₃⁻) Ion Selective Electrode (ISE), 1 m
ISENO318103IntelliCAL ISENO3181 Nitrate (NO₃⁻) Ion Selective Electrode (ISE), 3 m
ISENH4181APIntelliCAL ISENH418101 Ammonium (NH₄⁺) Ion Selective Electrode (ISE) w
ISENO3181APIntelliCAL ISENO318101 Nitrate (NO₃⁻) Ion Selective Electrode (ISE) wi
ISENA38103IntelliCAL ISENA381 Sodium (Na⁺) Ion Selective Electrode (ISE), 3 m ca
ISENA38101IntelliCAL ISENA381 Sodium (Na⁺) Ion Selective Electrode (ISE), 1 m ca
ISENH318103IntelliCAL ISENH3181 Ammonia (NH₃) Ion Selective Electrode (ISE), 3 m
ISENH318101IntelliCAL ISENH3181 Ammonia (NH₃) Ion Selective Electrode (ISE), 1 m
ISECL18101IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 1 m
ISECL18103IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 3 m
ISEF12101IntelliCAL ISEF121 Fluoride (F⁻) Ion Selective Electrode (ISE), 1 m ca
ISENH3181APIntelliCAL ISENH318101 Ammonia (NH₃) Ion Selective Electrode (ISE) wit
ISECL181APIntelliCAL ISECL18101 Chloride (Cl⁻) Ion Selective Electrode (ISE) wit
ISEF121APIntelliCAL ISEF12101 Fluoride (F⁻) Ion Selective Electrode (ISE) with
ISENA381APIntelliCAL ISENA38101 Sodium (Na⁺) Ion Selective Electrode (ISE) with

资料下载

18 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hach-lab — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hach-lab — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hach-lab — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hach-lab — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.

Implementation

The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.