GeneXpert IV, 2 Module Configuration with Laptop
HACH LEV016.97.00001
Wastewater surveillance for SARS-CoV-2, Flu, RSV, and beyond

产品概述

Wastewater surveillance for SARS-CoV-2, Flu, RSV, and beyond

Take control of your Wastewater Epidemiology testing with faster results, in a simplified process, and ability to run multiple samples on a single analyzer at a fraction of the overall cost.

主要特点

  • Reliable, accurate measurements:Anyone can run a consistent, reliable test for pathogens such as FLU/RSV and SARS-CoV-2 in wastewater with the GeneXpert fully automated PCR test. The test always runs the same way, allowing you to compare your results over time and across sites quickly and confidently.
  • Results in under an hour:When it comes to public health, time matters. Cepheid GeneXpert allows for testing of pathogens such as FLU/RSV and SARS-CoV-2 in wastewater at any location, with only 1-minute hands-on time and results available within one hour, generating near real-time data to better guide public health actions.
  • Save money with simple on-site testing:Build a robust wastewater monitoring program with no disruption to your daily work at a fraction of the cost of mail-in testing. Cepheid GeneXpert is simple for anyone to use regardless of expertise.

技术参数

参数名称说明
Analysis time45 min.
DimensionsH x W x D: 30.48 x 27.94 x 29.72 cm (12 x 11.1 x 11.7 in)
Gene targetLCE009: E, N2 & RdRP LCE010: E, N2, RdRP, M, PB2, PA, NS, RSV A & RSV B
Lower Limit of Detection (LOD)50,000 GU/L
Measurement MethodqPCR
Number of testsUp to 2 (GX-IV-2)
Operating Conditions15 - 30 °C (59 - 86 °F); 10 - 95% relative humidity, non-condensing
Power Requirements (Amps)1.5 A at 100 V, 0.75 A at 200 V
Power Requirements (Hz)50 - 60 Hz
Power Requirements (Voltage)100 - 240 VAC
ReagentFormat: Filtration (cartridge)
Sampling Time2 min.
Storage Conditions-30 °C - 45 °C (-22 °F - 113 °F); 0 - 95% relative humidity, non-condensing
Weight11.4 kg (25 lbs)
What's included?Cepheid GeneXpert IV-2 (2 module) Instrument Barcode Scanner Laptop & Ethernet cable User Manual

应用领域

Industrial Wastewater · Influent for Wastewater · Municipal Water

资料下载

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hach-lab — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hach-lab — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hach-lab — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hach-lab — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.

Implementation

The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.