Lico 620 Colorimeter for up to five color scales
HACH LMV187.53.20001
Colorimeter for color measurements of clear, transparent liquids with reference beam technology. Measures up to five ISO/ASTM color scales.

产品概述

Colorimeter for color measurements of clear, transparent liquids with reference beam technology. Measures up to five ISO/ASTM color scales.

主要特点

  • Hazen/APHA/PtCo-color:
  • Gardner-color:
  • Iodine-color:
  • Saybold-color:
  • ASTM D 1500:

技术参数

参数名称说明
Beam Height10
Color ScalesDIN 6162 iodine; ISO 6271 Hazen (Pt/Co, APHA, ASTM D1209, D5386); ISO 4630 Gardner (ASTM D1544, D6045); ASTM D 156 Saybolt; ASTM D 1500 mineral oil
Color Scales5
Cuvette Compatibility 210 mm rectangular sample cell
Cuvette Compatibility 350 mm rectangular sample cell
Dimensions (H x W x D)151 mm x 350 mm x 255 mm
DisplayTFT WVGA color graphic touch-screen
Display Resolution480 - 800 pixel
Display Size17.8 cm (7 in.)
Display TypeColor graphic
Interface2x USB Typ A, 1x USB Typ B, 1x Ethernet
Max. operating humidity80
Memory400 color readings
ModelLico 620
Operating Temperature Range10 - 40 °C
Optical Path Length10 - 50 mm
Optical System0° / 180° rectilinear
Photometric Accuracy0.005 Abs at 0 - 0.5 Abs
Photometric Accuracy 21 % at 0.5 - 2.0 Abs
Photometric Linearity< 0.5 % to 2 Abs with neutral glass at 546 nm
Photometric Linearity 2≤ 1 % with neutral glass at 546 nm
Power Requirements110 V - 240 V
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)100 - 240 VAC
Reproducibility±0.2 % transmission
Sample Cell Compatibility11 mm round sample cell
Source LampTungsten halogen lamp
Standard IlluminantC 2°
Standard Observer2°
Storage Conditions-40 °C - 60 °C
Stray radiant power ratio< 0.1 %T at 340 nm with NaNO2
User InterfaceTouch-screen, ext. USB keyboard
User Interface LanguagesEnglish, French, German, Italian, Spanish, Czech, Dutch, Greek, Polish, Slovene, Slovake, Russian, Turkish, Chinese, Japanese, Korean
Warranty12 months
Wavelength Accuracy±1.5 nm (wavelength range 340 - 900 nm)
Wavelength CalibrationAutomatic
Wavelength Range380 nm - 720 nm used for colorimetric calculations
Wavelength Reproducibility≤ 0.1
Weight4.2 kg
What's included?Instrument, power supply, printed basic user manual, CD with full user manual, 10 mm cell adapter, dust cover

应用领域

Discharge · Groundwater · Municipal Water · Potable Water · Surface Water

资料下载

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hach-lab — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hach-lab — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hach-lab — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hach-lab — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.

Implementation

The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.