Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

Radiometer Reference Electrodes

Radiometer Reference Electrodes
Radiometer Reference Electrodes
HACH ReferenceElectrode
Configurable Models 4 models
Radiometer Reference Electrodes

产品概述

The Radiometer REF201 Reference Electrode has a glass body, Red-Rod reference system, refillable electrolyte (sat. KCl), and porous pin junction. The REF201 reference probe is recommended for general purpose measurements. The REF201 has a 1 meter fixed cable with banana plug. It can be used with Radiometer MeterLab and Hach Sension+ Laboratory Meters.

主要特点

  • The right probe for your application.:To meet your analysis needs, Radiometer Analytical reference electrodes are available with a variety of reference systems and liquid junctions. There is a Radiometer electrode for every application.
  • Unique Red-Rod technology provides a reproducible, fast and accurate response.:The symmetry formed by the internal and external Red-Rod reference elements means that the iso pH is the same as the zero pH which provides highly reproducible results and a fast, accurate response, even when temperature fluctuations occur.
  • Know that you have the right answer.:Red-Rod electrodes provide a stable signal fast by protecting the reference elements from light interference. The Red-Rod saturated KCl salt-bridge also aids in creating a stable liquid junction potential.
  • Avoid problems with your measurement, even in challenging samples types.:The Red-Rod system creates a trouble-free liquid junction. The Red-Rod encapsulation of reference elements means no silver ions and therefore less risk of clogging when measuring in challenging sample matrices.
  • Measure over a wide temperature range.:The Red-Rod reference system enables use over a wider range of temperatures than for most pH electrodes.

技术参数

参数名称说明
Reference electrodeREF201
Warranty12 months
What's included?Includes: Radiometer Analytical REF201 reference electrode with Certificate of Conformity.

同系列其他配置

型号
E21M001Radiometer Analytical REF251 Red Rod Reference Electrode (double junct
E21M002Radiometer Analytical REF321 Reference Electrode (Ag/AgCl reference, s
E21M003Radiometer Analytical REF361 Reference Electrode (Ag/AgCl reference, s

资料下载

4 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hach-lab — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hach-lab — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hach-lab — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hach-lab — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.

Implementation

The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.