Principle of Operation:
The TU5200 Benchtop Turbidimeter uses 360°x90° optical path detection technology. A laser illuminates suspended particles in the sample, producing scattered light at 90° to the incident beam. After passing through a conical reflector, the light surrounds the sample at 360° and is then detected by the transmitted light detector. The intensity of the scattered light is proportional to the suspended particles. The TU5200 turbidimeter measures turbidity by measuring the intensity of scattered light produced by suspended particles.
Industry Applications:
The TU5200 Benchtop Turbidimeter is suitable for fields such as drinking water, power, beverages, and pharmaceuticals.
Instrument Features:
-
The TU5200 Benchtop Turbidimeter uses a unique 360° x 90° optical path design and detection technology, ensuring high accuracy in low turbidity measurement.
-
Single-point calibration is supported in the 0–40 NTU range, simplifying calibration of the benchtop turbidimeter.
-
The TU5200 Benchtop Turbidimeter does not require silicone oil or oil cloth to wipe the sample vials, reducing human error.
-
The benchtop turbidimeter is equipped with an Ethernet interface and a USB interface, allowing connection to a network or external devices for data input/output and printing functions.
-
The benchtop turbidimeter is equipped with a 7-inch color touchscreen, with a Chinese interface for more intuitive and convenient operation.
-
The TU5200 Benchtop Turbidimeter allows different levels of password protection to be set, ensuring test security.
Technical Specifications
-
Light source 650 nm (EPA) or 850 nm (ISO), maximum 1 mW. Class 2 laser product: contains a non-user-serviceable Class 2 laser. In accordance with Laser Notice No. 50, this product complies with IEC/EN 60825-1 and 21 CFR1040.10.
-
Measuring range EPA: 0 to 700 NTU, FNU, TE/F, FTU; 0 to 100 mg/L; 0 to 175 EBC
-
ISO: 0 to 1000 NTU / FNU / TE/F / FTU; 0 to 100 mg/L; 0 to 250 EBC
-
Accuracy 0 to 40 NTU: ±2% of reading plus 0.01 NTU
-
Based on Formazin primary standards, at 25 °C (77 °F), 40 to 700 NTU: ± 10% of reading
-
Resolution 0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L
-
Repeatability Based on Formazin primary standards, at 25°C (77°F), < 40 NTU: 0.002 NTU or 1% of reading (whichever is greater); > 40 NTU: better than 3.5% of reading
-
Stray light < 10 mNTU
-
Measurement units NTU, FNU, TE/F, FTU, EBC, mg/L, mNTU, mFNU
-
Operating temperature 10 to 40 °C (50 to 104°F), relative humidity 5 to 95%, non-condensing
-
Power requirements (voltage) 100 - 240 VAC
-
Power requirements (Hz) 50/60 Hz
Ordering Guide
-
TU5200 Laboratory Laser Turbidimeter
-
LPV442.99.01012 TU5200 Laboratory Laser Turbidimeter, 650 nm, EPA version
-
LPV442.99.01022 TU5200 Laboratory Laser Turbidimeter, 850 nm, ISO version
-
Calibration and Verification
-
LZY898 StablCal Calibration Kit
-
LZV946 TU5200 Sample Vials
Accessories
-
LZY903 TU5200/TU5300sc/TU5400sc Manual Vial Wiper
-
LZQ165 Silicone Vial Wiper, Automatic Cleaning Module
-
LZQ176 Fiber Vial Wiper, Automatic Cleaning Module
Source: Public information from the HACH Water Quality website
Case Studies
Municipal Wastewater Treatment · Hach-lab — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.
Configuration
Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.
Food & Beverage · Hach-lab — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.
What We Did
We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hach-lab — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.
Delivery Approach
Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.
Power & Energy · Hach-lab — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.
Implementation
The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.
Related Products
HACHDigester (rapid COD digester)
HACHWater quality analysis test strip series
HACHMulti-channel electrochemical analyzer
HACHPro/Pro+ pocket water tester
HACHLiquid colorimeter
HACHPortable water toxicity analyzer
HACH1000 series automatic potentiometric titrator
HACH