Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CL62.DXANAHD6KX

CL62.DXANAHD6KX
Product family: Capacitive level switch
Capacitive level switch
VEGA CL62.DXANAHD6KX
CL62.DXANAHD6KX;Approval II 1/2G, 2G Ex ia/db ia, db ia IIC T6...T1 Ga/Gb, Gb;Version / Process temperature Rod (ø12mm) 316L with PTFE insulation / -50...+150°C;Process fitting / Material Thread ¾NPT

Order Code:CL62.DXANAHD6KX

Name:CL62.DXANAHD6KX

Configuration

CodeNameOrderSpecification
030ApprovalDXII 1/2G, 2G Ex ia/db ia, db ia IIC T6...T1 Ga/Gb, Gb
040Version / Process temperatureARod (ø12mm) 316L with PTFE insulation / -50...+150°C
050Process fitting / MaterialNAThread ¾NPT PN64, ASME B1.20.1 / 316L
060ElectronicsHTwo-wire 4 ... 20 mA/HART
090Housing / ProtectionDAluminium double chamber / IP66/IP68 (0.2 bar)
110Cable entry / Cable gland / Plug connection6M20x1.5/for shielded cable (9...13mm) with strain relief/without
130Display/Adjustment module PLICSCOMKmounted; with Bluetooth, magnetic pen operation
140Additional equipmentXwithout

Configuration Explained

This is a CL62 capacitance level transmitter, rod probe, partially PTFE insulated, continuous level measurement, with combined intrinsically safe and flameproof approval, suitable for hazardous areas, 12 mm rod diameter, 316L, resistant to -50 to 150 °C, process connection ¾ NPT, according to ASME B1.20.1, 316L, North American thread fits directly on site, two-wire 4-20mA HART, aluminium dual chamber housing IP66/68, suitable for level measurement in hazardous areas with North American connections.

7 models · click to collapse