Product family:
Capacitive level switch
Capacitive level switch
CL64.XXRGAHKMAX;Approval without;Version / Process temperature Rod (Ø14mm) 316L with FEP insulation / -50...+150°C;Process fitting / Material Thread G¾ PN64, DIN3852-A / 316L;Electronics Two-wire 4 ..
Order Code:CL64.XXRGAHKMAX
Name:CL64.XXRGAHKMAX
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 030 | Approval | XX | without |
| 040 | Version / Process temperature | R | Rod (Ø14mm) 316L with FEP insulation / -50...+150°C |
| 050 | Process fitting / Material | GA | Thread G¾ PN64, DIN3852-A / 316L |
| 060 | Electronics | H | Two-wire 4 ... 20 mA/HART |
| 090 | Housing / Protection | K | Plastic single chamber / IP66/IP67 |
| 110 | Cable entry / Cable gland / Plug connection | M | M20x1.5 / with / without |
| 130 | Display/Adjustment module PLICSCOM | A | mounted |
| 150 | Additional equipment | X | without |
Configuration Explained
This is a CL64 capacitance level transmitter, bar probe, fully FEP insulated, specifically for adhesive media, 14 mm rod diameter, 316L, resistant to -50 to 150 °C, FEP surface does not hold material, process connection G¾ PN64, according to DIN3852, 316L, two-wire 4-20mA HART, plastic single chamber housing IP66/67, M20 entry, with mounted PLICSCOM display module, for level measurement of syrup and paste-like media.