Order Code:PS64.AEGGQIHXVDAXM
Name:VEGAPULS 64
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 020 | Scope | A | Europe |
| 030 | Approval | E | ATEX II 1/2G, 2G Ex db IIC T6 |
| 040 | Antenna version / Second Line of Defense | G | Flange with encapsulated antenna system / with |
| 050 | Process fitting / Material | GQ | Flange NPS 4" Class 300 RF, ASME B16.5 / 316/316L |
| 060 | Material / Seal / Process temperature | I | PTFE / PTFE / -40...+130 °C |
| 070 | Electronics | H | Two-wire 4 ... 20 mA/HART |
| 080 | Supplementary electronics | X | without |
| 110 | Housing / Protection | V | Stainless steel single chamber (precision casting) / IP66/IP68 (0.2 bar) |
| 130 | Cable entry / Connection | D | M20x1.5 / Blind plug |
| 140 | Display/Adjustment module PLICSCOM | A | mounted |
| 150 | Additional equipment | X | without |
| 160 | Certificates | M | Yes |
Configuration Explained
This is a VEGAPULS 64 radar level transmitter, flange with encapsulated antenna system, PTFE, with a second line of defence as well, process temperature -40 to 130°C, process connection NPS 4 inch Class300 RF flange, 316/316L, two-wire 4-20mA HART, stainless steel single chamber precision cast housing IP66/68, with PLICSCOM display, ATEX flameproof approval with certificate included, suitable for tanks of high pressure rating in hazardous areas.