产品概述
Ultra low range turbidity measurement.
Filtertrak Laser Nephelometer offers the best resolution in the market. Detects changes in turbidity as low as 0.0005 NTU. Complies with USEPA approved Hach Method 10133 for regulatory reporting and compliance monitoring. Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers, sensor can be used with Hach's new SC200 or SC1000 Digital Controllers. Includes Manual and Stablcal Turbidity Standards.
The FT660 is passing the torch to the TU5400 sc. The last day to order the FT660 is July 27, 2018. See the recommended products section of this page or visit HachTU5.com to learn more.
主要特点
- Lowest Limit of Detection in the Market:Using advanced laser optics and signal processing, the instrument detects increased concentrations of submicron-sized particles that are a precursor to larger particles. This allows for early filter deterioration detection that meets or exceeds that of particle counters all with the day-to-day convenience, simplicity, and reliability of a Hach turbidimeter. Operators can detect impending filter breakthrough, delineate filter ripening, and maximize effective filter run time. The Hach Filtertrak 660 sc Laser Nephelometer has the ability to detect a 0.3 mNTU or 0.0003 NTU change in turbidity, providing operators with confidence in their turbidity measurement.
- Meets All USEPA Filter Monitoring Requirements:The Filtertrak sensor uses U.S. Environmental Protection Agency (USEPA) approved Hach Filtertrak Method #10133, the method specified in the USEPA LT2 draft guidance manual for compliance monitoring of membrane filters. The sensor meets all regulatory requirements for individual filter and combined effluent monitoring.
- Monitor, Optimize, and Report:USEPA method compliance means that treatment plants with conventional or membrane filtration can monitor and optimize, as well as report, using this single technology.
- Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers:The Filtertrak sensor can be used with any of Hach's sc Digital Controllers. Each sc controller accepts from two to eight sensors. Multiple controllers can be networked to accommodate many more sensors and parameters, reducing the cost per measuring point. Just plug in any Hach “plug and play digital sensor and it's ready to use without software configuration. “Plug and play connectivity means there's no complicated wiring or set up. The Filtertrak 660 sc Laser Nephelometer controller system now can manage multiple digital sensors.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | (Defined according to ISO 15839) From ±3% of reading or ±5 mNTU, whichever is greater |
| Alarm | Three set-point alarms Two nephelometric set-point alarms (SOM required) |
| Cable Length | 1.8m (5.9 feet) |
| Calibration Method | Stablcal, stabilized formazin |
| Certifications | CE certified by Hach Company to EN61326 (industrial levels) |
| Certifications | Listed by ETL to UL 61010A-1: Certified by ETL to CSA C22.2 No. 1010.1: CE certified by Hach Company to EN 61010-1 |
| Communication | MODBUS® RS485/ RS232, PROFIBUS DP, HART available with sc controller |
| Controller | Dual Digital |
| Dimensions (H x W x D) | 406 mm x 305 mm x 254 mm |
| Display Resolution | 0.001 mNTU up to 9.9999 mNTU |
| Fitting Type | Sample Inlet: 1/4-inch NPT female, 1/2-inch hose barb (provided); Drain: 1/2-inch NPT female, 1/2-inch hose barb (provided), clear drain tubing is recommended |
| Flow | 100 - 750 mL/min |
| Flow Rate | 100 - 750 mL / min (1.6 to 11.9 gal/hour) |
| Light Source | 660 nm Laser Diode |
| Lower Limit of Detection (LOD) | (Defined according to ISO 15839) Less than 0.3 mNTU |
| Lowest Expected Reading | 5 mNTU using deionized, reverse osmosis water, based on statistical averages from three instruments |
| Measurement Frequency | One reading per second |
| Measuring Principle | Nephelometric light scatter at 90 degrees relative to incident monochromatic light beam |
| Mounting | Wall and floor stand |
| Number of Channels | 2 |
| Operating Humidity | 5 - 99 % non-condensing |
| Operating Temperature Range | 0 - 40 °C |
| Power Requirements (Voltage) | 100 - 240 VAC |
| Range | (0.0 - 5.0 NTU) 5000 mNTU = 5.000 NTU |
| Repeatability | + |
| Repeatability | (Defined according to ISO 15839) Better than ± 3.6 % of reading at 24 mNTU; as RSD (or as coefficient of variation) |
| Resolution | 0.01 mNTU from 10.00 - 99.99 mNTU |
| Resolution | 0.1 mNTU from 100.0 - 999.9 mNTU |
| Resolution | 1 mNTU from 1000 - 5000 mNTU |
| Sample Input | 0.25 " NPT female thread (1/4" compression fitting provided) |
| Sample Output | 0.5 " NPT female thread (1/2" hose barb provided) clear drain tubing is recommended |
| Sample Temperature | 0 - 50°C (32 - 122°F) |
| Signal Average Time | User selectable from 0, 6, 30, 60, 90 seconds; default 90 seconds |
| Storage Conditions | -20 °C to 60 °C |
| Warranty | 12 months |
| Weight | 4.54 kg |
| What's included? | Hach sc200 Controller, Mounting Hardware, sc200 Basic User Manual, FT660sc, FT660sc User Manual, and 1000 mL 800 mNTU Stablcal ®. (The controller power cord is ordered separately.) |
资料下载
- Monitoring Iron Transport in Power Generation- Application Note
- The Use of Simplified Statistical Processing Techniques to Increase Sensitivity of Detection to Particulate Breakthrough
- Monitoring Iron Transport in the Steam Cycle via Grab Sample and Online Methods
- Further Advances in Monitoring Low Level Iron in the Steam Cycle
- Monitoring Iron Transport in the Steam Cycle via Grab Sample and Online Methods
- Laser Nephelometer Calibration Guide for Monitoring Flow Accelerated Corrosion and Treatment Efficiency in the Steam Cycle
- Monitorización del transporte de hierro en el ciclo de vapor mediante muestras en el ciclo de vapor mediante muestras
- Introduction to Laser Nephelometry: An Alternative to Conventional Particulate Analysis Methods, by Mike Sadar, Hach Company
Casos de servicio
Tratamiento de Aguas Residuales Municipales — Controladores y sensores: caso de aplicación
Situación en planta
Se trata de un cliente del sector Tratamiento de Aguas Residuales Municipales cuya planta está en las etapas de entrada, biológica y salida de una planta municipal. La tarea principal era monitorización en línea con combinación de controlador y sensores.
El problema
La dificultad está en alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal; a la vez, los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Por eso la especificación implica emparejar cada canal del controlador con su tipo de sensor.
Qué hicimos
Adoptamos un enfoque de Hach: suministrar según referencias originales de Hach. La entrega se construyó en torno a emparejar cada canal del controlador con su tipo de sensor; se verificó punto por punto: cumplimiento estable del nivel 1A y reporte de datos en línea.
Resultado operativo
En servicio el sistema responde a lo previsto: combinaciones de fábrica que facilitan localizar fallos, con un mantenimiento rutinario notablemente menor.
Alimentación y Bebidas — Controladores y sensores: caso de aplicación
Contexto de aplicación
las etapas de dosificación, pasteurización, llenado y limpieza CIP es un servicio típico de Alimentación y Bebidas. El proyecto partió de Controladores y sensores, centrándose en monitorización en línea con combinación de controlador y sensores.
Limitaciones del proceso
las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente, y jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos no hace sino acentuarlo. Por eso la especificación de Controladores y sensores debe cubrir emparejar cada canal del controlador con su tipo de sensor.
Enfoque de suministro
La entrega se gestionó como Hach: suministrar según referencias originales de Hach. La ejecución se centró en emparejar cada canal del controlador con su tipo de sensor, junto con requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.
Resultados en campo
La operación evidencia el beneficio: combinaciones de fábrica que facilitan localizar fallos, con una confianza claramente mayor en este punto de medición.
Química y Farmacéutica — Controladores y sensores: caso de aplicación
Perfil del cliente
El entorno típico en Química y Farmacéutica es reactores, vasijas de dosificación y tanques de producto terminado. El punto de medición es Controladores y sensores; el foco es monitorización en línea con combinación de controlador y sensores.
Dificultades clave
Las condiciones son medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas y, encima, la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de emparejar cada canal del controlador con su tipo de sensor.
Implementación
El alcance se canalizó por la vía de Hach: suministrar según referencias originales de Hach. Técnicamente se apoya en emparejar cada canal del controlador con su tipo de sensor, y en estos requisitos: certificación Ex y trazabilidad de datos según GMP.
Beneficio para el cliente
En la práctica esto significa combinaciones de fábrica que facilitan localizar fallos, lo que redujo la carga del equipo de mantenimiento.
Energía y Electricidad — Controladores y sensores: caso de aplicación
Antecedentes del proyecto
El proyecto abarca agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El trabajo se centra en Controladores y sensores y la tarea principal es monitorización en línea con combinación de controlador y sensores.
Condiciones de servicio
El medio y el servicio se caracterizan por alta temperatura y presión, con vapor y agua salina, y además deriva a alta temperatura y presión, con paradas no programadas muy costosas. Por eso Controladores y sensores no puede especificarse de forma genérica: requiere emparejar cada canal del controlador con su tipo de sensor.
Solución
El equipo técnico de Ainstru trabajó por la vía de Hach: suministrar según referencias originales de Hach. La configuración incluye emparejar cada canal del controlador con su tipo de sensor; se cuidaron estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.
Resultados
Desde la puesta en marcha el sistema funciona de forma estable; el resultado práctico es combinaciones de fábrica que facilitan localizar fallos.