Principle of Operation:
The Amtax sc online ammonia nitrogen analyzer uses the ammonia gas-sensing electrode method for rapid determination of ammonia nitrogen.
Industry Applications:
The Amtax sc online ammonia nitrogen analyzer is suitable for rapid determination of ammonia nitrogen in drinking water, surface water, industrial process water, wastewater treatment processes, and wastewater discharge outlets.
Technical Specifications
-
Measuring range (NH4-N) 0.02 to 5.00 mg/L 0.05 to 20 mg/L 1 to 100 mg/L 10 to 1000 mg/L
-
Lowest detection limit 0.02 mg/L; 0.05 mg/L; 1 mg/L; 10 mg/L;
-
Accuracy Within 0.02~5 mg/L measuring range: at ≤1 mg/L, 3%+0.02 mg/L; at >1 mg/L, 5%+0.02 mg/L;
-
Within 0.05~20 mg/L measuring range: 3%±0.05 mg/L;
-
Within 1.0~100 mg/L measuring range: 3%±1.0 mg/L;
-
Within 10~1000 mg/L measuring range: 4.5%±10 mg/L;
-
Repeatability 3%±0.02 mg/L; 2%±0.05 mg/L; 2%±1.0 mg/L; 2%±10 mg/L;
-
Response time (T90) Within 0.02~5 mg/L range: 0.02~0.2 mg/L: 15 min; 0.2~5 mg/L: 5 min;
-
Within 0.05~20, 1~100, 10~1000 mg/L ranges: <5 min;
-
Measuring interval 5~120 min adjustable
-
Sample conditions Temperature: 4~40℃, pH: 5~9
-
Operating conditions Temperature: -20~45℃ Humidity: relative humidity 95% non-condensing
-
Power requirements 230 VAc/50 Hz or 115 VAc/50~60 Hz
-
Data transmission sc1000 multi-parameter universal controller with data cable or sc200 universal controller
-
Output via Relays, current outputs, and bus interfaces of the sc1000 multi-parameter universal controller or sc200 universal controller
-
Enclosure characteristics Complies with ANSI UV resistance requirements, lockable enclosure, protection rating up to IP65
-
Enclosure dimensions 540 × 720 × 390 mm
-
Cable length 2 meters from enclosure
-
Instrument weight 35 kg (including reagents)
-
Sample filtration Uses Filterprobe sc (see description below) or FILTRAX, ultrafiltration, etc. to obtain continuous sample (approximately 500~1000 mL/min)
-
Power consumption 100 W via analyzer (brief peak power consumption: 1000 VA), 5 or 10 meter heated hose for filter probe
-
Sample flow rate Maximum approximately 3 m/s
-
Filtrate flow rate At least 4 minutes out of every 5 minutes at approximately 5 mL/min
-
Enclosure dimensions 315 × 250 × 120 mm
Instrument Features:
-
The Amtax sc online ammonia nitrogen analyzer uses the ammonia gas-sensing electrode method for rapid determination of ammonia nitrogen, with four measuring ranges available and a wide measuring range.
-
The Amtax sc online ammonia nitrogen analyzer has a lowest detection limit of 0.02 mg/L and high accuracy.
-
Built-in plug-and-play full-function digital controller with good expandability.
-
Optional sampling pretreatment system enables integrated sampling, measurement, and data transmission, intelligent and reliable.
-
The Amtax sc online ammonia nitrogen analyzer features automatic cleaning, automatic calibration, and automatic diagnostics, minimizing maintenance workload.
-
The Amtax sc online ammonia nitrogen analyzer requires no reaction reagents, and the electrode filling solution can be used for at least 3 months, resulting in low operating costs.
-
The Amtax sc online ammonia nitrogen analyzer has fast response speed and can adapt to the rapid ammonia nitrogen determination requirements of different types of water samples.
Spare Parts
| Spare Part Order No. | Instrument Model | Chinese Description | English Description |
|---|---|---|---|
| 2955300 | Amtax sc online ammonia nitrogen analyzer | Electrolyte kit | KTO: AMTAX MEMBRANE CAPS & ELECT (LR) |
| LZP365 | Amtax sc online ammonia nitrogen analyzer | Solenoid stirring stick | Solenoid stirring stick (8x3 mm) |
| LZY007 | Amtax sc online ammonia nitrogen analyzer | Plugs (rubber) | Set of plugs (rubber) for sc-analyser |
| LZY069 | Amtax sc online ammonia nitrogen analyzer | Electrode | Special electrode AMTAX sc |
| LZY070 | Amtax sc online ammonia nitrogen analyzer | Electrode | Special electrode AMTAX sc |
| LZY111 | Amtax sc online ammonia nitrogen analyzer | Fittings kit | Set of fittings 3.2 mm |
| LZY134 | Amtax sc online ammonia nitrogen analyzer | Tubing fitting | Fitting for tubing DN 4/6 |
| LZY145 | Amtax sc online ammonia nitrogen analyzer | Enclosure (without door) | Enclosure for sc-analyser |
| LZY149 | Amtax sc online ammonia nitrogen analyzer | Switchable compressor | Compressor switchable 115 V/230 V |
| LZY150 | Amtax sc online ammonia nitrogen analyzer | Locking screw | Locking screw |
| LZY151 | Amtax sc online ammonia nitrogen analyzer | Compressor air tubing | Air tubing for compressor |
| LZY152 | Amtax sc online ammonia nitrogen analyzer | Inlet fan | Fan for incoming air |
| LZY153 | Amtax sc online ammonia nitrogen analyzer | Air recirculation fan | Fan for air recirculation for sc-analyser |
| LZY154 | Amtax sc online ammonia nitrogen analyzer | Filter pads | Set of filter pads (2 pieces) |
| LZY156 | Amtax sc online ammonia nitrogen analyzer | Enclosure heater | Heating for analyser enclosure |
| LZY162 | Amtax sc online ammonia nitrogen analyzer | Analytical section | Analytical section of AMTAX sc |
| LZY165 | Amtax sc online ammonia nitrogen analyzer | Bottom part of overflow vessel | Bottom part of overflow vessel |
| LZY166 | Amtax sc online ammonia nitrogen analyzer | Upper part of overflow vessel | Upper part of overflow vessel |
| LZY167 | Amtax sc online ammonia nitrogen analyzer | Upper part of overflow vessel incl. valve | Upper part of overflow vessel incl. valve |
| LZY168 | Amtax sc online ammonia nitrogen analyzer | 2/2 valve | Valve 2/2 ways |
| LZY169 | Amtax sc online ammonia nitrogen analyzer | Valve block (valves for all ranges) | Valve block for AMTAX sc incl. valves |
| LZY170 | Amtax sc online ammonia nitrogen analyzer | Conversion kit | Conversion kit |
| LZY171 | Amtax sc online ammonia nitrogen analyzer | 3-way valve | Valve 3/2 ways |
| LZY172 | Amtax sc online ammonia nitrogen analyzer | 2-channel switching valve block | Valve block 2-channel switch |
| LZY173 | Amtax sc online ammonia nitrogen analyzer | Valve block (all ranges) | Valve block for AMTAX sc |
| LZY174 | Amtax sc online ammonia nitrogen analyzer | Upper part of valve block | Upper part of valve block |
| LZY175 | Amtax sc online ammonia nitrogen analyzer | Upper part of valve block with valve | Upper part of valve block with valve |
| LZY177 | Amtax sc online ammonia nitrogen analyzer | Piston pump | Piston pump for sc-analyser |
| LZY180 | Amtax sc online ammonia nitrogen analyzer | Piston pump holder | Holder for piston pump |
| LZY181 | Amtax sc online ammonia nitrogen analyzer | Air pump head | Pump head for air pump 10 mL |
| LZY182 | Amtax sc online ammonia nitrogen analyzer | Stirrer motor | Stirrer motor AMTAX sc |
| LZY184 | Amtax sc online ammonia nitrogen analyzer | Measuring cell | Measuring cell AMTAX sc |
| LZY188 | Amtax sc online ammonia nitrogen analyzer | Door lock | Door lock sc-analyser |
| LZY189 | Amtax sc online ammonia nitrogen analyzer | Instrument components (for continuous sampling) | KIT, ACCESSORIES SC ANALYZER |
| LZY190 | Amtax sc online ammonia nitrogen analyzer | Connector kit | Set of connectors for sc-analysers |
| LZY192 | Amtax sc online ammonia nitrogen analyzer | Fittings kit | Set of fittings 1.6 mm |
| LZY193 | Amtax sc online ammonia nitrogen analyzer | Blind plug | Blind plug |
| LZY194 | Amtax sc online ammonia nitrogen analyzer | Tubing (1.6 mm) | Tubing 1.6 mm (2 m) |
| LZY195 | Amtax sc online ammonia nitrogen analyzer | Tubing (3.2 mm) | Tubing 3.2 mm (2 m) |
| LZY196 | Amtax sc online ammonia nitrogen analyzer | Seal kit | Set of seals for AMTAX sc |
| LZY198 | Amtax sc online ammonia nitrogen analyzer | Overflow vessel seal | Sealing for overflow vessel |
| LZY199 | Amtax sc online ammonia nitrogen analyzer | Valve block seal | Sealing for valve block |
| LZY200 | Amtax sc online ammonia nitrogen analyzer | Tool for electrode pair | TOOL FOR ELECTRODE, SPECIAL |
| LZY216 | Amtax sc online ammonia nitrogen analyzer | Screws for fastening and angle bracket | Set of screws for fastening and angle bracket |
| LZY223 | Amtax sc online ammonia nitrogen analyzer | Instrument screws | Set of screws for sc-analyser |
| LZY267 | Amtax sc online ammonia nitrogen analyzer | Valve block 2-channel switch (incl. instrument valves) | Valve block 2-channel switch |
| LZY268 | Amtax sc online ammonia nitrogen analyzer | Upper part of overflow vessel for 1 or 2 channels | Upper part of overflow vessel |
| LZY269 | Amtax sc online ammonia nitrogen analyzer | Overflow vessel for 2-channel | Overflow vessel for 2-channel |
| LZY270 | Amtax sc online ammonia nitrogen analyzer | Cover | Cover |
| LZY285 | Amtax sc online ammonia nitrogen analyzer | Rail mounting (for instrument with controller) | Rail mounting for analyser |
| LZY286 | Amtax sc online ammonia nitrogen analyzer | Stand mounting (for instrument with controller) | Stand mounting for sc-analyser |
| LZY287 | Amtax sc online ammonia nitrogen analyzer | Stand mounting (for instrument without controller) | Stand mounting for sc-analyser |
| LZY316 | Amtax sc online ammonia nitrogen analyzer | Rail mounting (for instrument without controller) | Rail mounting for analyser |
| LZY830 | Amtax sc online ammonia nitrogen analyzer | Reagent pump | VALVE PUMP CONVERSION KIT AMTAX SC,2 PUMPS |
| LZY831 | Amtax sc online ammonia nitrogen analyzer | Reagent pump | VALVE PUMP CONVERSION KIT AMTAX SC, 1 PUMP |
| LZY832 | Amtax sc online ammonia nitrogen analyzer | Reagent pump | VALVE PUMP CONVERSION KIT PSC & ASC |
| YAB044 | Amtax sc online ammonia nitrogen analyzer | Amplifier circuit board | Amplifier card for AMTAX sc |
| YAB089 | Amtax sc online ammonia nitrogen analyzer | Sensor card | Card with temperature sensor |
| YAB099 | Amtax sc online ammonia nitrogen analyzer | Main board | Processor card for sc- |
Related Reagents
| Order No. | Description | Parameter | Analysis Method | Packaging | Measuring Range | Guaranteed Shelf Life (days) |
|---|---|---|---|---|---|---|
| 2894452-CN | Reagent F, for AMTAX analyzer, 2500 mL | - | Ammonia effluent 0.05-20.0 mg/L Ammonia effluent 0.2-5.0 mg/L Ammonia effluent 10-1000 mg/L Ammonia effluent 1-100 mg/L Ammonium effluent 0.05-20.0 mg/L Ammonium effluent 0.2-5.0 mg/L Ammonium effluent 10-1000 mg/L Ammonium effluent 1-100 mg/L |
- | - | 900 |
| 2894154-CN | 1 mg/L, NH4-N standard solution, 2000 mL | Ammonium | Photometric pH indicator expulsion method | - | 0.05-20.0 mg/L | 900 |
| 2894354 | 10 mg/L, NH4-N standard solution, 2000 mL | Ammonium | Photometric pH indicator expulsion method | - | 0.05-20.0 mg/L | 900 |
| 2825854 | 50 mg/L, NH4-N standard solution, 2000 mL | - | Ammonia effluent 0.05-20.0 mg/L Ammonia effluent 0.2-5.0 mg/L Ammonia effluent 10-1000 mg/L Ammonia effluent 1-100 mg/L Ammonium effluent 0.05-20.0 mg/L Ammonium effluent 0.2-5.0 mg/L Ammonium effluent 10-1000 mg/L Ammonium effluent 1-100 mg/L |
- | - | 900 |
| 2825954 | 500 mg/L, NH4-N standard solution, 2000 mL | Ammonium | Photometric pH indicator expulsion method | - | 0.05-20.0 mg/L | 900 |
Ordering Guide
-
The standard configuration of the AMTAX sc ammonia nitrogen analyzer includes: AMTAX sc ammonia nitrogen analyzer main unit, filter probe, mounting accessories, operation manual, reagents, etc. The sc1000 or sc200 controller must be ordered separately
-
61570-00 AMTAX sc ammonia nitrogen analyzer, 0.05-20 mg/L, 220 V; includes filter probe with 5 m heated hose
-
61571-00 AMTAX sc ammonia nitrogen analyzer, 0.05-20 mg/L, 220 V; includes filter probe with 10 m heated hose
-
61576-00 AMTAX sc ammonia nitrogen analyzer, 1-100 mg/L, 220 V; includes filter probe with 5 m heated hose
-
61577-00 AMTAX sc ammonia nitrogen analyzer, 1-100 mg/L, 220 V; includes filter probe with 10 m heated hose
-
61582-00 AMTAX sc ammonia nitrogen analyzer, 10-1000 mg/L, 220 V; includes filter probe with 5 m heated hose
-
61583-00 AMTAX sc ammonia nitrogen analyzer, 10-100 mg/L, 220 V; includes filter probe with 10 m heated hose
-
AMTAX sc ammonia nitrogen analyzer main unit (controller and filter probe not included)
-
61574-00 AMTAX sc ammonia nitrogen analyzer main unit, 0.05-20 mg/L, single-channel continuous sampling, 220 V,
-
61580-00 AMTAX sc ammonia nitrogen analyzer main unit, 1-100 mg/L, single-channel continuous sampling, 220 V,
-
61586-00 AMTAX sc ammonia nitrogen analyzer main unit, 10-1000 mg/L, single-channel continuous sampling, 220 V,
-
For AMTAX sc dual-channel ammonia nitrogen analyzer, please contact Hach company offices in China
-
Single Amtax sc (without Filter Probe sc)
-
90091-00 Amtax sc ammonia nitrogen analyzer 0.02-5 mg/L, 115-230 Vac; continuous single-channel sampling
-
90092-00 Amtax sc ammonia nitrogen analyzer 0.02-5 mg/L, 115-230 Vac; continuous dual-channel sampling
-
Amtax sc ammonia nitrogen analyzer (with Filterprobe sc)
-
90089-00 Amtax sc ammonia nitrogen analyzer 0.02-5 mg/L, 230 Vac; with 5 m heated filtration probe
-
90090-00 Amtax sc ammonia nitrogen analyzer 0.02-5 mg/L, 230 Vac; with 10 m heated filtration probe
-
Sample filtration
-
LXV429.99.01000 Filterprobe sc, 5 m heated hose, 220V/50Hz
-
LXV429.99.02000 Filterprobe sc, 10 m heated hose, 220V/50Hz
-
Mounting accessories
-
LZY285 Rail mounting kit for AMTAX sc ammonia nitrogen analyzer with sc1000 controller
-
LZY316 Rail mounting kit for AMTAX sc ammonia nitrogen analyzer without sc1000 controller
-
LZY286 Stand mounting kit for AMTAX sc ammonia nitrogen analyzer with sc1000 controller
-
LZY287 Stand mounting kit for AMTAX sc ammonia nitrogen analyzer without sc1000 controller
-
LZY714.99.42020 Edge mounting kit for Filterprobe sc
-
LZX414.00.60000 Rail mounting kit for Filterprobe sc
-
Reagents
-
28941-54 1 mg/L NH4-N ammonia nitrogen standard solution, 2000 mL
-
28943-54 10 mg/L NH4-N ammonia nitrogen standard solution, 2000 mL
-
28258-54 50 mg/L NH4-N ammonia nitrogen standard solution, 2000 mL
-
28259-54 500 mg/L NH4-N ammonia nitrogen standard solution, 2000 mL
-
28944-52 AMTAX sc reagent, 2500 mL
-
61825-00 AMTAX sc electrolyte, 11 mL
-
28942-46 AMTAX sc cleaning solution, 250 mL
-
2514654 0.5 mg/L NH4-N standard solution, 2000 ML
-
2514754 2.5 mg/L NH4-N standard solution, 2000 ML
-
2955300 Electrode kit, includes electrolyte and membrane cap (one year supply)
-
Replaceable Parts
-
LZY069 Ammonia nitrogen electrode for AMTAX sc analyzer
-
LZY181 Air pump head for AMTAX sc analyzer
-
LZY140 Filter membrane assembly for Filterprobe sc
-
LQV155.99.00002 Power box, without power connection cable, for use when Amtax sc is connected to sc200
Source: Hach Water Quality website public information
Casos de servicio
Tratamiento de Aguas Residuales Municipales — HACH-ONLINE: caso de aplicación
Antecedentes del proyecto
El proyecto abarca las etapas de entrada, biológica y salida de una planta municipal. El trabajo se centra en HACH-ONLINE y la tarea principal es monitorización continua de vertido con instrumentos Hach.
Condiciones de servicio
El medio y el servicio se caracterizan por alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y además los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Por eso HACH-ONLINE no puede especificarse de forma genérica: requiere configurar por rango, intervalo de reactivo y acondicionamiento.
Solución
El equipo técnico de Ainstru trabajó por la vía de análisis en línea: integrar en torno a cada punto de monitorización. La configuración incluye configurar por rango, intervalo de reactivo y acondicionamiento; se cuidaron estos requisitos: cumplimiento estable del nivel 1A y reporte de datos en línea.
Resultados
Desde la puesta en marcha el sistema funciona de forma estable; el resultado práctico es suministro estable de reactivos y consumibles, con mantenimiento previsible.
Alimentación y Bebidas — HACH-ONLINE: caso de aplicación
Resumen del proyecto
La instalación está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. El cliente quería configurar bien HACH-ONLINE en la planta existente, con el objetivo de monitorización continua de vertido con instrumentos Hach.
Retos técnicos
Lo que realmente da problemas es jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos, y las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Todo ello implica que la configuración de HACH-ONLINE deba incluir configurar por rango, intervalo de reactivo y acondicionamiento.
Configuración
El suministro y la instalación se organizaron por la vía de análisis en línea: integrar en torno a cada punto de monitorización. En planta esto supuso configurar por rango, intervalo de reactivo y acondicionamiento; se revisó línea a línea: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.
Comportamiento
Tras la puesta en marcha el resultado es suministro estable de reactivos y consumibles, con mantenimiento previsible, y las lecturas se usan ya para ajustar el proceso.
Química y Farmacéutica — HACH-ONLINE: caso de aplicación
Situación en planta
Se trata de un cliente del sector Química y Farmacéutica cuya planta está en reactores, vasijas de dosificación y tanques de producto terminado. La tarea principal era monitorización continua de vertido con instrumentos Hach.
El problema
La dificultad está en medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas; a la vez, la corrosión y la protección Ex acortan la vida útil y encarecen las paradas. Por eso la especificación implica configurar por rango, intervalo de reactivo y acondicionamiento.
Qué hicimos
Adoptamos un enfoque de análisis en línea: integrar en torno a cada punto de monitorización. La entrega se construyó en torno a configurar por rango, intervalo de reactivo y acondicionamiento; se verificó punto por punto: certificación Ex y trazabilidad de datos según GMP.
Resultado operativo
En servicio el sistema responde a lo previsto: suministro estable de reactivos y consumibles, con mantenimiento previsible, con un mantenimiento rutinario notablemente menor.
Energía y Electricidad — HACH-ONLINE: caso de aplicación
Contexto de aplicación
agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx es un servicio típico de Energía y Electricidad. El proyecto partió de HACH-ONLINE, centrándose en monitorización continua de vertido con instrumentos Hach.
Limitaciones del proceso
deriva a alta temperatura y presión, con paradas no programadas muy costosas, y alta temperatura y presión, con vapor y agua salina no hace sino acentuarlo. Por eso la especificación de HACH-ONLINE debe cubrir configurar por rango, intervalo de reactivo y acondicionamiento.
Enfoque de suministro
La entrega se gestionó como análisis en línea: integrar en torno a cada punto de monitorización. La ejecución se centró en configurar por rango, intervalo de reactivo y acondicionamiento, junto con cumplimiento de normativas del sector y objetivos de disponibilidad.
Resultados en campo
La operación evidencia el beneficio: suministro estable de reactivos y consumibles, con mantenimiento previsible, con una confianza claramente mayor en este punto de medición.
Recomendados similares
HACHAnalizador de fósforo total / ortofosfato Sigma
Analizador COD en línea por método dicromato sc
HACHAnalizador de dureza del agua en línea
HACHAnalizador automático multiparamétrico de agua
HACHAnalizador multiparamétrico de agua en línea
HACHAnalizador de sílice en línea
HACHAnalizador de nitrógeno amoniacal
HACH