Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

AMTAX sc ammonia nitrogen online analyzer

AMTAX sc ammonia nitrogen online analyzer
sc ammonia nitrogen online analyzer
HACH AMTAX
The Amtax sc online ammonia nitrogen analyzer uses the gas-sensitive electrode method for rapid ammonia nitrogen measurement, with four measuring ranges, a detection limit as low as 0.02 mg/L, and good expandability. A controller is available as an option. It is an online ammonia nitrogen analyzer capable of automatic cleaning, calibration, and diagnostics.

Principle of Operation:

The Amtax sc online ammonia nitrogen analyzer uses the ammonia gas-sensing electrode method for rapid determination of ammonia nitrogen.

Industry Applications:

The Amtax sc online ammonia nitrogen analyzer is suitable for rapid determination of ammonia nitrogen in drinking water, surface water, industrial process water, wastewater treatment processes, and wastewater discharge outlets.

Technical Specifications

  • Measuring range (NH4-N)    0.02 to 5.00 mg/L 0.05 to 20 mg/L 1 to 100 mg/L 10 to 1000 mg/L

  • Lowest detection limit    0.02 mg/L; 0.05 mg/L; 1 mg/L; 10 mg/L;

  • Accuracy    Within 0.02~5 mg/L measuring range: at ≤1 mg/L, 3%+0.02 mg/L; at >1 mg/L, 5%+0.02 mg/L;

  • Within 0.05~20 mg/L measuring range: 3%±0.05 mg/L;

  • Within 1.0~100 mg/L measuring range: 3%±1.0 mg/L;

  • Within 10~1000 mg/L measuring range: 4.5%±10 mg/L;

  • Repeatability    3%±0.02 mg/L; 2%±0.05 mg/L; 2%±1.0 mg/L; 2%±10 mg/L;

  • Response time (T90)    Within 0.02~5 mg/L range: 0.02~0.2 mg/L: 15 min; 0.2~5 mg/L: 5 min;

  • Within 0.05~20, 1~100, 10~1000 mg/L ranges: <5 min;

  • Measuring interval    5~120 min adjustable

  • Sample conditions    Temperature: 4~40℃, pH: 5~9

  • Operating conditions    Temperature: -20~45℃ Humidity: relative humidity 95% non-condensing

  • Power requirements    230 VAc/50 Hz or 115 VAc/50~60 Hz

  • Data transmission    sc1000 multi-parameter universal controller with data cable or sc200 universal controller

  • Output via    Relays, current outputs, and bus interfaces of the sc1000 multi-parameter universal controller or sc200 universal controller

  • Enclosure characteristics    Complies with ANSI UV resistance requirements, lockable enclosure, protection rating up to IP65

  • Enclosure dimensions    540 × 720 × 390 mm

  • Cable length    2 meters from enclosure

  • Instrument weight    35 kg (including reagents)

  • Sample filtration    Uses Filterprobe sc (see description below) or FILTRAX, ultrafiltration, etc. to obtain continuous sample (approximately 500~1000 mL/min)

  • Power consumption    100 W via analyzer (brief peak power consumption: 1000 VA), 5 or 10 meter heated hose for filter probe

  • Sample flow rate    Maximum approximately 3 m/s

  • Filtrate flow rate    At least 4 minutes out of every 5 minutes at approximately 5 mL/min

  • Enclosure dimensions    315 × 250 × 120 mm

Instrument Features:

  • The Amtax sc online ammonia nitrogen analyzer uses the ammonia gas-sensing electrode method for rapid determination of ammonia nitrogen, with four measuring ranges available and a wide measuring range.

  • The Amtax sc online ammonia nitrogen analyzer has a lowest detection limit of 0.02 mg/L and high accuracy.

  • Built-in plug-and-play full-function digital controller with good expandability.

  • Optional sampling pretreatment system enables integrated sampling, measurement, and data transmission, intelligent and reliable.

  • The Amtax sc online ammonia nitrogen analyzer features automatic cleaning, automatic calibration, and automatic diagnostics, minimizing maintenance workload.

  • The Amtax sc online ammonia nitrogen analyzer requires no reaction reagents, and the electrode filling solution can be used for at least 3 months, resulting in low operating costs.

  • The Amtax sc online ammonia nitrogen analyzer has fast response speed and can adapt to the rapid ammonia nitrogen determination requirements of different types of water samples.

Spare Parts

Spare Part Order No. Instrument Model Chinese Description English Description
2955300 Amtax sc online ammonia nitrogen analyzer Electrolyte kit KTO: AMTAX MEMBRANE CAPS & ELECT (LR)
LZP365 Amtax sc online ammonia nitrogen analyzer Solenoid stirring stick Solenoid stirring stick (8x3 mm)
LZY007 Amtax sc online ammonia nitrogen analyzer Plugs (rubber) Set of plugs (rubber) for sc-analyser
LZY069 Amtax sc online ammonia nitrogen analyzer Electrode Special electrode AMTAX sc
LZY070 Amtax sc online ammonia nitrogen analyzer Electrode Special electrode AMTAX sc
LZY111 Amtax sc online ammonia nitrogen analyzer Fittings kit Set of fittings 3.2 mm
LZY134 Amtax sc online ammonia nitrogen analyzer Tubing fitting Fitting for tubing DN 4/6
LZY145 Amtax sc online ammonia nitrogen analyzer Enclosure (without door) Enclosure for sc-analyser
LZY149 Amtax sc online ammonia nitrogen analyzer Switchable compressor Compressor switchable 115 V/230 V
LZY150 Amtax sc online ammonia nitrogen analyzer Locking screw Locking screw
LZY151 Amtax sc online ammonia nitrogen analyzer Compressor air tubing Air tubing for compressor
LZY152 Amtax sc online ammonia nitrogen analyzer Inlet fan Fan for incoming air
LZY153 Amtax sc online ammonia nitrogen analyzer Air recirculation fan Fan for air recirculation for sc-analyser
LZY154 Amtax sc online ammonia nitrogen analyzer Filter pads Set of filter pads (2 pieces)
LZY156 Amtax sc online ammonia nitrogen analyzer Enclosure heater Heating for analyser enclosure
LZY162 Amtax sc online ammonia nitrogen analyzer Analytical section Analytical section of AMTAX sc
LZY165 Amtax sc online ammonia nitrogen analyzer Bottom part of overflow vessel Bottom part of overflow vessel
LZY166 Amtax sc online ammonia nitrogen analyzer Upper part of overflow vessel Upper part of overflow vessel
LZY167 Amtax sc online ammonia nitrogen analyzer Upper part of overflow vessel incl. valve Upper part of overflow vessel incl. valve
LZY168 Amtax sc online ammonia nitrogen analyzer 2/2 valve Valve 2/2 ways
LZY169 Amtax sc online ammonia nitrogen analyzer Valve block (valves for all ranges) Valve block for AMTAX sc incl. valves
LZY170 Amtax sc online ammonia nitrogen analyzer Conversion kit Conversion kit
LZY171 Amtax sc online ammonia nitrogen analyzer 3-way valve Valve 3/2 ways
LZY172 Amtax sc online ammonia nitrogen analyzer 2-channel switching valve block Valve block 2-channel switch
LZY173 Amtax sc online ammonia nitrogen analyzer Valve block (all ranges) Valve block for AMTAX sc
LZY174 Amtax sc online ammonia nitrogen analyzer Upper part of valve block Upper part of valve block
LZY175 Amtax sc online ammonia nitrogen analyzer Upper part of valve block with valve Upper part of valve block with valve
LZY177 Amtax sc online ammonia nitrogen analyzer Piston pump Piston pump for sc-analyser
LZY180 Amtax sc online ammonia nitrogen analyzer Piston pump holder Holder for piston pump
LZY181 Amtax sc online ammonia nitrogen analyzer Air pump head Pump head for air pump 10 mL
LZY182 Amtax sc online ammonia nitrogen analyzer Stirrer motor Stirrer motor AMTAX sc
LZY184 Amtax sc online ammonia nitrogen analyzer Measuring cell Measuring cell AMTAX sc
LZY188 Amtax sc online ammonia nitrogen analyzer Door lock Door lock sc-analyser
LZY189 Amtax sc online ammonia nitrogen analyzer Instrument components (for continuous sampling) KIT, ACCESSORIES SC ANALYZER
LZY190 Amtax sc online ammonia nitrogen analyzer Connector kit Set of connectors for sc-analysers
LZY192 Amtax sc online ammonia nitrogen analyzer Fittings kit Set of fittings 1.6 mm
LZY193 Amtax sc online ammonia nitrogen analyzer Blind plug Blind plug
LZY194 Amtax sc online ammonia nitrogen analyzer Tubing (1.6 mm) Tubing 1.6 mm (2 m)
LZY195 Amtax sc online ammonia nitrogen analyzer Tubing (3.2 mm) Tubing 3.2 mm (2 m)
LZY196 Amtax sc online ammonia nitrogen analyzer Seal kit Set of seals for AMTAX sc
LZY198 Amtax sc online ammonia nitrogen analyzer Overflow vessel seal Sealing for overflow vessel
LZY199 Amtax sc online ammonia nitrogen analyzer Valve block seal Sealing for valve block
LZY200 Amtax sc online ammonia nitrogen analyzer Tool for electrode pair TOOL FOR ELECTRODE, SPECIAL
LZY216 Amtax sc online ammonia nitrogen analyzer Screws for fastening and angle bracket Set of screws for fastening and angle bracket
LZY223 Amtax sc online ammonia nitrogen analyzer Instrument screws Set of screws for sc-analyser
LZY267 Amtax sc online ammonia nitrogen analyzer Valve block 2-channel switch (incl. instrument valves) Valve block 2-channel switch
LZY268 Amtax sc online ammonia nitrogen analyzer Upper part of overflow vessel for 1 or 2 channels Upper part of overflow vessel
LZY269 Amtax sc online ammonia nitrogen analyzer Overflow vessel for 2-channel Overflow vessel for 2-channel
LZY270 Amtax sc online ammonia nitrogen analyzer Cover Cover
LZY285 Amtax sc online ammonia nitrogen analyzer Rail mounting (for instrument with controller) Rail mounting for analyser
LZY286 Amtax sc online ammonia nitrogen analyzer Stand mounting (for instrument with controller) Stand mounting for sc-analyser
LZY287 Amtax sc online ammonia nitrogen analyzer Stand mounting (for instrument without controller) Stand mounting for sc-analyser
LZY316 Amtax sc online ammonia nitrogen analyzer Rail mounting (for instrument without controller) Rail mounting for analyser
LZY830 Amtax sc online ammonia nitrogen analyzer Reagent pump VALVE PUMP CONVERSION KIT AMTAX SC,2 PUMPS
LZY831 Amtax sc online ammonia nitrogen analyzer Reagent pump VALVE PUMP CONVERSION KIT AMTAX SC, 1 PUMP
LZY832 Amtax sc online ammonia nitrogen analyzer Reagent pump VALVE PUMP CONVERSION KIT PSC & ASC
YAB044 Amtax sc online ammonia nitrogen analyzer Amplifier circuit board Amplifier card for AMTAX sc
YAB089 Amtax sc online ammonia nitrogen analyzer Sensor card Card with temperature sensor
YAB099 Amtax sc online ammonia nitrogen analyzer Main board Processor card for sc-

Related Reagents

Order No. Description Parameter Analysis Method Packaging Measuring Range Guaranteed Shelf Life (days)
2894452-CN Reagent F, for AMTAX analyzer, 2500 mL - Ammonia effluent 0.05-20.0 mg/L
Ammonia effluent 0.2-5.0 mg/L
Ammonia effluent 10-1000 mg/L
Ammonia effluent 1-100 mg/L
Ammonium effluent 0.05-20.0 mg/L
Ammonium effluent 0.2-5.0 mg/L
Ammonium effluent 10-1000 mg/L
Ammonium effluent 1-100 mg/L
- - 900
2894154-CN 1 mg/L, NH4-N standard solution, 2000 mL Ammonium Photometric pH indicator expulsion method - 0.05-20.0 mg/L 900
2894354 10 mg/L, NH4-N standard solution, 2000 mL Ammonium Photometric pH indicator expulsion method - 0.05-20.0 mg/L 900
2825854 50 mg/L, NH4-N standard solution, 2000 mL - Ammonia effluent 0.05-20.0 mg/L
Ammonia effluent 0.2-5.0 mg/L
Ammonia effluent 10-1000 mg/L
Ammonia effluent 1-100 mg/L
Ammonium effluent 0.05-20.0 mg/L
Ammonium effluent 0.2-5.0 mg/L
Ammonium effluent 10-1000 mg/L
Ammonium effluent 1-100 mg/L
- - 900
2825954 500 mg/L, NH4-N standard solution, 2000 mL Ammonium Photometric pH indicator expulsion method - 0.05-20.0 mg/L 900

Ordering Guide

  • The standard configuration of the AMTAX sc ammonia nitrogen analyzer includes: AMTAX sc ammonia nitrogen analyzer main unit, filter probe, mounting accessories, operation manual, reagents, etc. The sc1000 or sc200 controller must be ordered separately

  • 61570-00    AMTAX sc ammonia nitrogen analyzer, 0.05-20 mg/L, 220 V; includes filter probe with 5 m heated hose

  • 61571-00    AMTAX sc ammonia nitrogen analyzer, 0.05-20 mg/L, 220 V; includes filter probe with 10 m heated hose

  • 61576-00    AMTAX sc ammonia nitrogen analyzer, 1-100 mg/L, 220 V; includes filter probe with 5 m heated hose

  • 61577-00    AMTAX sc ammonia nitrogen analyzer, 1-100 mg/L, 220 V; includes filter probe with 10 m heated hose

  • 61582-00    AMTAX sc ammonia nitrogen analyzer, 10-1000 mg/L, 220 V; includes filter probe with 5 m heated hose

  • 61583-00    AMTAX sc ammonia nitrogen analyzer, 10-100 mg/L, 220 V; includes filter probe with 10 m heated hose

  • AMTAX sc ammonia nitrogen analyzer main unit (controller and filter probe not included)

  • 61574-00    AMTAX sc ammonia nitrogen analyzer main unit, 0.05-20 mg/L, single-channel continuous sampling, 220 V,

  • 61580-00    AMTAX sc ammonia nitrogen analyzer main unit, 1-100 mg/L, single-channel continuous sampling, 220 V,

  • 61586-00    AMTAX sc ammonia nitrogen analyzer main unit, 10-1000 mg/L, single-channel continuous sampling, 220 V,

  • For AMTAX sc dual-channel ammonia nitrogen analyzer, please contact Hach company offices in China

  • Single Amtax sc (without Filter Probe sc)

  • 90091-00    Amtax sc ammonia nitrogen analyzer 0.02-5 mg/L, 115-230 Vac; continuous single-channel sampling

  • 90092-00    Amtax sc ammonia nitrogen analyzer 0.02-5 mg/L, 115-230 Vac; continuous dual-channel sampling

  • Amtax sc ammonia nitrogen analyzer (with Filterprobe sc)

  • 90089-00    Amtax sc ammonia nitrogen analyzer 0.02-5 mg/L, 230 Vac; with 5 m heated filtration probe

  • 90090-00    Amtax sc ammonia nitrogen analyzer 0.02-5 mg/L, 230 Vac; with 10 m heated filtration probe

  • Sample filtration

  • LXV429.99.01000    Filterprobe sc, 5 m heated hose, 220V/50Hz

  • LXV429.99.02000    Filterprobe sc, 10 m heated hose, 220V/50Hz

  • Mounting accessories

  • LZY285    Rail mounting kit for AMTAX sc ammonia nitrogen analyzer with sc1000 controller

  • LZY316    Rail mounting kit for AMTAX sc ammonia nitrogen analyzer without sc1000 controller

  • LZY286    Stand mounting kit for AMTAX sc ammonia nitrogen analyzer with sc1000 controller

  • LZY287    Stand mounting kit for AMTAX sc ammonia nitrogen analyzer without sc1000 controller

  • LZY714.99.42020    Edge mounting kit for Filterprobe sc

  • LZX414.00.60000    Rail mounting kit for Filterprobe sc

  • Reagents

  • 28941-54    1 mg/L NH4-N ammonia nitrogen standard solution, 2000 mL

  • 28943-54    10 mg/L NH4-N ammonia nitrogen standard solution, 2000 mL

  • 28258-54    50 mg/L NH4-N ammonia nitrogen standard solution, 2000 mL

  • 28259-54    500 mg/L NH4-N ammonia nitrogen standard solution, 2000 mL

  • 28944-52    AMTAX sc reagent, 2500 mL

  • 61825-00    AMTAX sc electrolyte, 11 mL

  • 28942-46    AMTAX sc cleaning solution, 250 mL

  • 2514654    0.5 mg/L NH4-N standard solution, 2000 ML

  • 2514754    2.5 mg/L NH4-N standard solution, 2000 ML

  • 2955300    Electrode kit, includes electrolyte and membrane cap (one year supply)

  • Replaceable Parts

  • LZY069    Ammonia nitrogen electrode for AMTAX sc analyzer

  • LZY181    Air pump head for AMTAX sc analyzer

  • LZY140    Filter membrane assembly for Filterprobe sc

  • LQV155.99.00002    Power box, without power connection cable, for use when Amtax sc is connected to sc200

Source: Hach Water Quality website public information

Municipal Wastewater Treatment

Municipal Wastewater Treatment · HACH-ONLINE — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on HACH-ONLINE and the core task is continuous outfall monitoring with Hach online instruments.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So HACH-ONLINE cannot be specified generically — it calls for configured by monitoring range, reagent replacement interval and conditioning.

Solution

The Ainstru engineering team worked through the online water-analysis line: integrating around each online monitoring point. The configuration involves configured by monitoring range, reagent replacement interval and conditioning, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is steady reagent and consumable supply, making upkeep predictable.

Food & Beverage

Food & Beverage · HACH-ONLINE — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted HACH-ONLINE properly configured on the existing plant, with the aim of continuous outfall monitoring with Hach online instruments.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the HACH-ONLINE configuration has to involve configured by monitoring range, reagent replacement interval and conditioning.

Configuration

Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured by monitoring range, reagent replacement interval and conditioning, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is steady reagent and consumable supply, making upkeep predictable, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · HACH-ONLINE — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was continuous outfall monitoring with Hach online instruments.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by monitoring range, reagent replacement interval and conditioning.

What We Did

We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured by monitoring range, reagent replacement interval and conditioning, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — steady reagent and consumable supply, making upkeep predictable, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · HACH-ONLINE — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from HACH-ONLINE, focusing on continuous outfall monitoring with Hach online instruments.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The HACH-ONLINE specification must therefore cover configured by monitoring range, reagent replacement interval and conditioning.

Delivery Approach

Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured by monitoring range, reagent replacement interval and conditioning, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — steady reagent and consumable supply, making upkeep predictable, with confidence in this measuring point improving markedly.