SC4500 Controller, Claros-enabled, 2 Digital Sensors, 100-240 VAC, without power cord
HACH LXV525.99AA0552
Digital controller for up to two compatible instruments. Technologies are advancing rapidly, providing new levels of convenience, accuracy, and efficiency. Which is exactly why the SC4500 Controller f

产品概述

Ready for Now. Ready for the Future.

Digital controller for up to two compatible instruments. Technologies are advancing rapidly, providing new levels of convenience, accuracy, and efficiency. Which is exactly why the SC4500 Controller from HachⓇ is designed to integrate easily into your current system while allowing you to upgrade as your capabilities advance, without having to replace inventory. With a wide range of analog and digital connectivity options and the availability of intelligent instrument and data management features, the SC4500 unlocks the future, today.

主要特点

  • Easy Adoption:The familiar experience of a modern touchscreen, the ability to use your current Hach sensors, and the same footprint as the SC200, make installation and integration of the SC4500 Controller seamless.
  • No Time for Downtime:The SC4500's built-in predictive diagnostic software ensures measurement confidence and reduces the risk of unexpected equipment downtime by enabling proactive maintenance planning via MSM, including step-by-step instructions.
  • The Connectivity Options You Need:The Controller is Smart Monitoring enabled and provides local communication to SCADA or a PLC. From analog and advanced digital protocols to Wi-Fi, cellular or LAN, the SC4500 gives you the flexibility to adapt in a rapidly changing world.

技术参数

参数名称说明
Altitude3000 m (9842 ft) maximum
Analog Output Functional ModeLinear, PID
Communication (optional)Analog: Five 0 - 20 mA or 4 - 20 mA analog outputs on each analog output module Up to two analog Input modules (0 - 20 mA or 4 - 20 mA). Each input module replaces a digital sensor input. Digital: Profibus DPV1 module with S2 redundancy Modbus TCP Modbus RS Profinet IO module Ethernet IP module HART module
Compatible InstrumentsCompatible Sensors and Analysers / Software Version (Release Year) Amtax sc / V2.30 (2018) or higher A-ISE sc / V1.02 or higher AN-ISE sc / V1.08 (2013) or higher N-ISE sc / V1.02 or higher NH6000sc Ammonium Analyser Nitratax clear sc, Nitratax eco sc, Nitratax plus sc / V3.13 (2013) or higher NT3100sc/NT3200sc Phosphax sc / V2.30 (2018) or higher Phosphax sc LR/MR/HR / V1.01 (2018) or higher TSS sc / V41.73 (2013) or higher Solitax sc / V2.20 (2013) or higher TU5300sc, TU5400sc / V1.34 (2017) or higher SS7 sc (in Bypass) / V1.01 (2006) or higher Ultraturb sc / V3.06 (2017) or higher 1720E / V2.10 (2006) or higher Sonatax sc / V1.15 (2016) or higher CL17sc / V2.7 (2019) or higher CL10sc / V1.14 (2013) or higher 9184sc, 9185sc, 9187sc* / V2.03 (2013) or higher Uvas plus sc / V3.01 (2017) or higher LDO 2 sc* / V1.22 (2013) or higher 3798sc* / V2.03 (2013) or higher 3700sc + Inductive Conductive Digital 6120800 / V3.00 (2017) or higher 3422sc + Contacting Conductive Digital 6120700 / V3.00 or higher 3700 analog + Conductivity Module LXZ525.99.D0004 3400 analog + Conductivity Module LXZ525.99.D0004 pHD sc*, pHD-S sc / V3.10 (2016) or higher 1200-S sc* / V2.04 (2013) or higher pHD analog + Digital Gateway 6120500 / V3.00 (2017) or higher pHD analog + pH/ORP Module LXZ525.99.D0003 RC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600 / V3.00 (2017) or higher RC and PC analog + pH/ORP Module LXZ525.99.D0003 8362sc* / V3.00 (2017) or higher Polymetron pH/ORP analog + Ultrapure pH/ORP Module LXZ525.99.D0007 Polymetron Conductivity analog + Ultrapure Conductivity Module LXZ525.99.D0006 GS1440 and GS2440EX Sensors H₂S FP360 sc / V1 or higher *Hardware Version1 of instrument is not supported
Compatible Network TechnologiesGSM 3G/4G (e.g. AT&T, T-Mobile, Rogers, Vodafone etc.) CDMA (e.g. Verizon)
Compliance CertificationsCE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, C م (Morocco) C1D2 (available for specific models and North-America only)
Conduit Openings½" NPT conduit
DescriptionMicroprocessor-controlled and menu-driven controller that operates the sensor
Dimensions½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)
Display3.5-inch TFT color display with capacitive touchpad
Enclosure RatingUL50E type 4X, IEC/EN 60529–IP 66, NEMA 250 type 4X Metal enclosure with a corrosion-resistant finish
Indoor/OutdoorOutdoor installation in direct sunlight or UV radiation requires UV protection screen and/or sunroof
Installation CategoryCategory II
Material EnclosuresPolycarbonate, aluminum (powder coated), stainless steel
MeasurementsTwo device digital SC connectors
MountingWall, Pole, or Panel Mounting
Network ConnectivityOptional: LAN: Two Ethernet connectors (10/100 Mbps) Cellular: External 4G Wi-Fi
Operating Temperature Range-20 - 60 °C (-4 - 140 °F) (8 W (AC)/9 W (DC) sensor load) -20 - 45 °C (-4 - 113 °F) (28 W (AC)/20 W (DC) sensor load) Linear derating between 45 and 60 °C (-1.33 W/°C)
Pollution Degree4
Power Requirements (Voltage)100 - 240 VAC ±10%, 50/60 Hz; 1 A
Power SupplyWithout power cord
Protection ClassI, connected to protective earth
RelaysTwo relays (SPDT); Wire gauge: 0.75 to 1.5 mm² (18 to 16 AWG) Maximum switching voltage: 100 - 240 VAC Maximum switching current: 5 A Resistive/1 A Pilot Duty Maximum switching power: 1200 VA Resistive/360 VA Pilot Duty
Sensor Input #1Digital
Sensor Input #2Digital
Software AvailableClaros-enabled
Storage Conditions-20 - 70 °C (-4 - 158 °F), 0 - 95% relative humidity, non-condensing
USB PortUsed for data download and software upload. The controller records approximately 20,000 data points for each connected sensor.
Warranty12 months
Weight1.7 kg (3.7 lb) (controller only, w/o modules)
What's included?SC4500 Controller, Claros-enabled, without power cord; includes mounting hardware

应用领域

Anaerobic Digestion Biogas · Aquaculture · Ballast Water · Biosolids Dewatering · Boiler Water · Clean in Place (CIP) · Cooling Water · Discharge · Filtration · Flow Monitoring · Groundwater · Industrial Wastewater · Influent for Wastewater · Membrane Protection · Municipal Water · Neutralization · Nutrient Monitoring · Petrochemical · Potable Water · Pre-Treatment · Primary Treatment · Product Loss · Production Water · QA/QC Lab · Recreation/Pool · Regulations · Sea Water · Secondary Treatment · Solids Handling · Source Water · Steam Cycle · Storm Water · Surface Water · Tertiary Treatment · Ultrapure Water · Water Conditioning · Water Cycle · Water Reuse · Water Supply Conditioning

资料下载

Tratamiento de Aguas Residuales Municipales

Tratamiento de Aguas Residuales Municipales — Controladores y sensores: caso de aplicación

Situación en planta

Se trata de un cliente del sector Tratamiento de Aguas Residuales Municipales cuya planta está en las etapas de entrada, biológica y salida de una planta municipal. La tarea principal era monitorización en línea con combinación de controlador y sensores.

El problema

La dificultad está en alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal; a la vez, los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Por eso la especificación implica emparejar cada canal del controlador con su tipo de sensor.

Qué hicimos

Adoptamos un enfoque de Hach: suministrar según referencias originales de Hach. La entrega se construyó en torno a emparejar cada canal del controlador con su tipo de sensor; se verificó punto por punto: cumplimiento estable del nivel 1A y reporte de datos en línea.

Resultado operativo

En servicio el sistema responde a lo previsto: combinaciones de fábrica que facilitan localizar fallos, con un mantenimiento rutinario notablemente menor.

Alimentación y Bebidas

Alimentación y Bebidas — Controladores y sensores: caso de aplicación

Contexto de aplicación

las etapas de dosificación, pasteurización, llenado y limpieza CIP es un servicio típico de Alimentación y Bebidas. El proyecto partió de Controladores y sensores, centrándose en monitorización en línea con combinación de controlador y sensores.

Limitaciones del proceso

las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente, y jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos no hace sino acentuarlo. Por eso la especificación de Controladores y sensores debe cubrir emparejar cada canal del controlador con su tipo de sensor.

Enfoque de suministro

La entrega se gestionó como Hach: suministrar según referencias originales de Hach. La ejecución se centró en emparejar cada canal del controlador con su tipo de sensor, junto con requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.

Resultados en campo

La operación evidencia el beneficio: combinaciones de fábrica que facilitan localizar fallos, con una confianza claramente mayor en este punto de medición.

Química y Farmacéutica

Química y Farmacéutica — Controladores y sensores: caso de aplicación

Perfil del cliente

El entorno típico en Química y Farmacéutica es reactores, vasijas de dosificación y tanques de producto terminado. El punto de medición es Controladores y sensores; el foco es monitorización en línea con combinación de controlador y sensores.

Dificultades clave

Las condiciones son medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas y, encima, la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de emparejar cada canal del controlador con su tipo de sensor.

Implementación

El alcance se canalizó por la vía de Hach: suministrar según referencias originales de Hach. Técnicamente se apoya en emparejar cada canal del controlador con su tipo de sensor, y en estos requisitos: certificación Ex y trazabilidad de datos según GMP.

Beneficio para el cliente

En la práctica esto significa combinaciones de fábrica que facilitan localizar fallos, lo que redujo la carga del equipo de mantenimiento.

Energía y Electricidad

Energía y Electricidad — Controladores y sensores: caso de aplicación

Antecedentes del proyecto

El proyecto abarca agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El trabajo se centra en Controladores y sensores y la tarea principal es monitorización en línea con combinación de controlador y sensores.

Condiciones de servicio

El medio y el servicio se caracterizan por alta temperatura y presión, con vapor y agua salina, y además deriva a alta temperatura y presión, con paradas no programadas muy costosas. Por eso Controladores y sensores no puede especificarse de forma genérica: requiere emparejar cada canal del controlador con su tipo de sensor.

Solución

El equipo técnico de Ainstru trabajó por la vía de Hach: suministrar según referencias originales de Hach. La configuración incluye emparejar cada canal del controlador con su tipo de sensor; se cuidaron estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.

Resultados

Desde la puesta en marcha el sistema funciona de forma estable; el resultado práctico es combinaciones de fábrica que facilitan localizar fallos.