Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

5H1B50-AADBACQFIAS0A+LPLT

5H1B50-AADBACQFIAS0A+LPLT
Product family: Electromagnetic flowmeter 5H1B
Electromagnetic flowmeter 5H1B
Endress+Hauser 5H1B50-AADBACQFIAS0A+LPLT
Electromagnetic flowmeter 5H1B;Approval Non-hazardous area;Power Supply DC 24V;Output/Input 4-20mA HART, pulse/freq./switch output;Display/Operation W/o; via communication;Housing **Ultra compact hygienic, stainless;Electrical Connection 2x plug M12x1;Seal Aseptic shape, EPDM;Process Connection Welding nipple ISO 2037, 1.4404/316L;Electrodes 1.4435/316L;Flow Calibration 0.5%;Additional Approval 3-A;Additional Approval EHEDG

Order Code:5H1B50-AADBACQFIAS0A+LPLT

Name:Electromagnetic flowmeter 5H1B

Configuration

CodeNameOrderSpecification
010ApprovalAANon-hazardous area
015Power SupplyDDC 24V
020Output; InputB4-20mA HART, pulse/freq./switch output
030Display; OperationAW/o; via communication
040HousingC**Ultra compact hygienic, stainless
050Electrical ConnectionQ2x plug M12x1
060SealFAseptic shape, EPDM
070Process ConnectionIASWelding nipple ISO 2037, 1.4404/316L
075Electrodes01.4435/316L
080Flow CalibrationA0.5%
590Additional ApprovalLP3-A
590Additional ApprovalLTEHEDG
2 models · click to collapse