Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

5H3B65-KUX2/0

5H3B65-KUX2/0
Product family: Electromagnetic flowmeter
Electromagnetic flowmeterIn Stock (5)
Endress+Hauser 5H3B65-KUX2/0
Promag H 300, 5H3B65, DN65 2 1/2";Approval/Transmitter + Sensor Non-hazardous area;Power Supply AC 100...240V/DC 24V;Output/Input 1 4-20mA HART;Output/Input 2 Pulse/freq./switch output;Output/Input 3
H3B65-KUX2/0

Corresponding ext. order code:5H3B65-AAIBAEBFAAFDAS0EA2

Name:Promag H 300, 5H3B65, DN65 2 1/2"

Configuration

CodeNameOrderSpecification
010Approval; Transmitter + SensorAANon-hazardous area
015Power SupplyIAC 100...240V/DC 24V
020Output; Input 1BA4-20mA HART
021Output; Input 2EPulse/freq./switch output
022Output; Input 3B4-20mA
030Display; OperationF4-line illum.; touch control
040HousingAAlu, coated
050Electrical ConnectionAGland M20
060SealFAseptic shape, EPDM
070Process ConnectionDASWelding nipple EN 10357 series A, 1.4404/316L
075Electrodes01.4435/316L
080Flow CalibrationE0.2%, 3-point, traceable ISO/IEC 17025
480Device ModelA22

Configuration Explained

This is a 5H3B electromagnetic flowmeter dedicated to the hygienic industry, with an ultra-compact transmitter, non-hazardous area, 100-230V AC or 24V DC supply, 4-20mA HART output, pulse, frequency and switch plus one 4-20mA channel, three signals delivered at the same time, four-line backlit display with touch keys, coated aluminium housing with EPDM corrosion-resistant seal, welded spud EN10357, 316L, DIN11850, 316L electrodes, 0.2% three-point calibration traceable to ISO/IEC17025, suitable for dairy and pharmaceutical lines that require a calibration certificate.

20 models · click to collapse