Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

5H5B08-AAIBAEAAFAAALABO2VDAA2+ABZ1

5H5B08-AAIBAEAAFAAALABO2VDAA2+ABZ1
Product family: Electromagnetic flowmeter 5H5B
Electromagnetic flowmeter 5H5B
Endress+Hauser 5H5B08-AAIBAEAAFAAALABO2VDAA2+ABZ1
Promag H 500, 5H5B08, DN08 5/16";Approval/Transmitter/Sensor Non-hazardous area;Power Supply AC 100...240V/DC 24V;Output/Input 1 4-20mA HART;Output/Input 2 Pulse/freq./switch output;Output/Input 3 W/o

Order Code:5H5B08-AAIBAEAAFAAALABO2VDAA2+ABZ1

Name:Promag H 500, 5H5B08, DN08 5/16"

Configuration

CodeNameOrderSpecification
010Approval; Transmitter; SensorAANon-hazardous area
015Power SupplyIAC 100...240V/DC 24V
020Output; Input 1BA4-20mA HART
021Output; Input 2EPulse/freq./switch output
022Output; Input 3AW/o;
023Output; Input 4AW/o;
030Display; OperationF4-line illum.; touch control
035Integrated ISEM ElectronicASensor
041Transmitter HousingAAlu, coated
042Sensor Junction HousingAAlu, coated
045Cable, Sensor ConnectionL10m/30ft digital
050Electrical ConnectionAGland M20
060SealBO-ring, FKM
070Process ConnectionO2VAdhesive fitting 20x2mm tube, PVC
075ElectrodesDTantal + 2x grounding ring
080Flow CalibrationA0.5%
480Device ModelA22
500Operation Language DisplayABGerman
895MarkingZ1Tagging (TAG), see additional spec.

Configuration Explained

This is a 5H5B electromagnetic flowmeter, expert for the hygiene industry, remote transmitter with up to 4 input and output channels, non-hazardous area, 100-230V AC or 24V DC supply, 4-20mA HART plus pulse, frequency and switch, 4-line backlit touch keys, transmitter and sensor housings in coated aluminium, 10 m digital cable, FKM O-ring seal, process connection is a 20x2mm pipe adhesive adapter, PVC, tantalum electrodes plus 2 grounding rings, suitable for small hygienic pipelines.

1 models · click to collapse