Order Code:5WBB2H-AADAEBJA0AQD210AA1+AK
Name:Electromagnetic flowmeter 10
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval; Transmitter + Sensor | AA | Non-hazardous area |
| 011 | Design | D | Lap joint flange |
| 013 | Functionality | A | Standard transmitter |
| 015 | Power Supply | E | AC 100...240V |
| 020 | Output; Input | B | 4-20mA HART, pulse/freq./switch output |
| 030 | Display; Operation | J | LCD, 2.40"; Bluetooth technology |
| 040 | Housing | A | Compact, alu, coated |
| 045 | Cable, Sensor Connection | 0 | Not used |
| 050 | Electrical Connection | A | Gland M20 |
| 060 | Liner | Q | PTFE 90oC |
| 070 | Process Connection | D21 | PN10, carbon steel, lap joint flange, stamped plate EN1092-1 |
| 075 | Electrodes | 0 | 1.4435/316L |
| 080 | Flow Calibration | A | 0.5% |
| 480 | Device Model | A1 | 1 |
| 500 | Operation Language Display | AK | Chinese simplified |
Configuration Explained
This is the electromagnetic flowmeter 10 series, for standard water and wastewater applications, non-hazardous area, loose flange design, 100-240V AC supply, 4-20mA HART plus pulse, frequency and switch, 2.4 inch LCD with Bluetooth app, viewed as soon as the phone connects, compact coated aluminium housing, M20 entry, PTFE liner rated to 90 °C, PN10 carbon steel loose flange, suitable for flow metering of corrosive wastewater.