Order Code:5WBB1H-AADAEBKA0AUD210AA1+AK
Name:Promag W 10, 5WBB1H, DN100 4"
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval; Transmitter + Sensor | AA | Non-hazardous area |
| 011 | Design | D | Lap joint flange |
| 013 | Functionality | A | Standard transmitter |
| 015 | Power Supply | E | AC 100...240V |
| 020 | Output; Input | B | 4-20mA HART, pulse/freq./switch output |
| 030 | Display; Operation | K | LCD, 2.40"; touch screen, Bluetooth technology |
| 040 | Housing | A | Compact, alu, coated |
| 045 | Cable, Sensor Connection | 0 | Not used |
| 050 | Electrical Connection | A | Gland M20 |
| 060 | Liner | U | Polyurethane |
| 070 | Process Connection | D21 | PN10, carbon steel, lap joint flange, stamped plate EN1092-1 |
| 075 | Electrodes | 0 | 1.4435/316L |
| 080 | Flow Calibration | A | 0.5% |
| 480 | Device Model | A1 | 1 |
| 500 | Operation Language Display | AK | Chinese simplified |
Configuration Explained
This is the electromagnetic flowmeter 10 series, standard water and wastewater applications, non-hazardous area, loose flange, 100-240V AC supply, 4-20mA HART plus pulse, frequency and switch outputs, 2.4 inch touch screen with Bluetooth app, trends visible on site, compact coated aluminium housing, wear and erosion resistant polyurethane liner, PN10 carbon steel loose flange, suitable for metering wastewater with high solids content.
Related Products
Endress+HauserElectromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter 10
Endress+HauserElectromagnetic flowmeter
Endress+HauserBattery-powered electromagnetic flowmeter
Endress+HauserMAGPHANT
Endress+HauserElectromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter
Siemens