Order Code:5WBB40-AADAEMJM0AUD210AA1
Name:Electromagnetic flowmeter 10
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval; Transmitter + Sensor | AA | Non-hazardous area |
| 011 | Design | D | Lap joint flange |
| 013 | Functionality | A | Standard transmitter |
| 015 | Power Supply | E | AC 100...240V |
| 020 | Output; Input | M | Modbus RS485, 4-20mA |
| 030 | Display; Operation | J | LCD, 2.40"; Bluetooth technology |
| 040 | Housing | M | Compact, polycarbonate |
| 045 | Cable, Sensor Connection | 0 | Not used |
| 050 | Electrical Connection | A | Gland M20 |
| 060 | Liner | U | Polyurethane |
| 070 | Process Connection | D21 | PN10, carbon steel, lap joint flange, stamped plate EN1092-1 |
| 075 | Electrodes | 0 | 1.4435/316L |
| 080 | Flow Calibration | A | 0.5% |
| 480 | Device Model | A1 | 1 |
Configuration Explained
This is the electromagnetic flowmeter 10 series, standard water industry applications, non-hazardous area, nominal size DN40, loose flange, 100-240V AC supply, Modbus RS485 plus 4-20mA output, digital signal goes straight into the system, 2.4 inch LCD with Bluetooth app, compact polycarbonate housing, light and transparent, polyurethane liner, PN10 carbon steel loose flange, suitable for wastewater metering points in digital upgrades.
Related Products
Endress+HauserElectromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter 10
Endress+HauserElectromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter
Endress+HauserBattery-powered electromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter
Endress+HauserMAGPHANT
Endress+Hauser