Order Code:7F2C15-AAGCCAAABAAAASKA1
Name:Prowirl F 200, 7F2C15, DN15 1/2"
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 020 | Output; Input | G | PROFIBUS PA, pulse/freq./switch output |
| 030 | Display; Operation | C | SD02 4-line; push buttons + data backup function |
| 040 | Housing | C | GT20 dual compartment,alu,coated,compact |
| 045 | Cable, Remote Version | A | Not used |
| 050 | Electrical Connection | A | Gland M20 |
| 060 | Sensor Version; DSC-Sensor; Meas. Tube | AB | Volume; Alloy C22; 316L -40...+260oC/-40...+500oF |
| 061 | DSC-Sensor Seal | A | Graphite, -200oC… +400oC, -328oF…752oF |
| 065 | Pressure component | A | Not used |
| 070 | Process Connection | AAS | Cl.150 RF Sch.40, flange ASME B16.5 |
| 080 | Flow Calibration | K | 0.75% volume 3-point |
| 480 | Device Model | A1 | 1 |
Configuration Explained
This is a vortex flowmeter, multi-function high-accuracy model, with wet steam detection, used in non-hazardous areas, with PROFIBUS PA bus, plus pulse frequency and switch output, with four-line LCD display, key operation, parameters can be backed up, dual chamber aluminium housing with coating, impact resistant, combined Alloy C22 and 316L wetted parts, withstands -40 to 260 °C, with Class150 RF US standard flange, Sch.40 pipe, suitable for flow metering of steam, gases and liquids.