Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

7F2C1F-AABLCAAAAAAAASKA1

7F2C1F-AABLCAAAAAAAASKA1
Product family: Vortex flowmeter
Vortex flowmeter
Endress+Hauser 7F2C1F-AABLCAAAAAAAASKA1
Belongs to 7F2C(7F2C)
Vortex flowmeter;Approval Non-hazardous area;Output/Input 4-20mA HART, pulse/freq./switch output;Display/Operation Prepared for display FHX50 + M12 connection;Housing GT20 dual compartment,alu,coated,compact;Cable, Remote Version Not used;Electrical Connection Gland M20;Sensor Version/DSC-Sensor/Meas. Tube Volume; 316L; 316L -40...+260oC/-40...+500oF;DSC-Sensor Seal Graphite, -200oC… +400oC, -328oF…752oF;Pressure component Not used;Process Connection Cl.150 RF Sch.40, flange

Order Code:7F2C1F-AABLCAAAAAAAASKA1

Name:Vortex flowmeter

Configuration

CodeNameOrderSpecification
010ApprovalAANon-hazardous area
020Output; InputB4-20mA HART, pulse/freq./switch output
030Display; OperationLPrepared for display FHX50 + M12 connection
040HousingCGT20 dual compartment,alu,coated,compact
045Cable, Remote VersionANot used
050Electrical ConnectionAGland M20
060Sensor Version; DSC-Sensor; Meas. TubeAAVolume; 316L; 316L -40...+260oC/-40...+500oF
061DSC-Sensor SealAGraphite, -200oC… +400oC, -328oF…752oF
065Pressure componentANot used
070Process ConnectionAASCl.150 RF Sch.40, flange ASME B16.5
080Flow CalibrationK0.75% volume 3-point
480Device ModelA11

Configuration Explained

This is a 7F2C1F vortex flowmeter, multi-function type with wet steam detection, measures volumetric flow, for non-hazardous areas, 4-20mA HART plus pulse frequency and switch output, with FHX50 display and M12 connection, aluminium dual chamber housing, M20 cable entry, 2-inch Class150 US standard flange, 316L sensor withstands -40 to 260 °C, 0.75% three-point calibration, stable reading without fluctuation.