Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

92F Ultrasonic flowmeter

92F Ultrasonic flowmeter
Ultrasonic flowmeter 92F
Configurable Models 1 models
Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.
Compare

Liquids

Measuring Principle Ultrasonic flow
Product headline Higly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs.
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry.
Sensor features Safe design for process industries – international hazardous area approvals. No additional pressure loss – full-bore design. Process transparency – diagnostic capability.
Full compliance according to NACE MR0175 and MR010. Nominal diameter: DN 25 to 300 (1 to 12"). Medium temperature: –40 to 200 °C (–40 to 392 °F).
Transmitter features Easy installation and reduced installation costs – loop-powered transmitter. Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI. Automatic recovery of data for servicing.
Device as compact or remote version. 2-line backlit display with push buttons. HART.
Nominal diameter range 2 path version: DN80 to 300 (3 to12")
3 path version: DN25 to 50 (1 to 2")
4 path version: DN 80 to 300 (3 to 12")
Wetted materials Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432
Measured variables Volume flow, calculated mass flow, sound velocity, flow velocity, signal strength
Max. measurement error Volume flow (standard):
- ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
- ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Measuring range 0.5 to 10 m/s (1.6 to 33 ft/s)
Max. process pressure PN 40 / ASME Cl. 300 / JIS 20K
Medium temperature range -40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional
Ambient temperature range -40 to +60 °C (-40 to +140 °F) compact
-40 to +80 °C (-40 to +176 °F) remote sensor
-40 to +60 °C (-40 to +140 °F) remote transmitter
Transmitter housing material AlSi10Mg, coated
Degree of protection IP67, type 4X enclosure
IP68 type 6P enclosure (option for remote)
Display/Operation 2 lines backlit display with 3 push buttons
Outputs 1x 4-20 mA HART
1x Pulse/frequency/switch output (passive)
Inputs N/A
Digital communication HART
Power supply 2 wire loop powered
Hazardous area approvals ATEX,FM, CSA, JPNm UK Ex
Other approvals and certificates 3.1 material (wetted parts), calibration performed on accredited
calibration facilities (acc. to ISO/IEC 17025), CRN, AD2000
PED, EAC marking
Product safety EAC marking
Metrological approvals and certificates calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure approvals and certificates CRN, PED, AD2000
Material certificates 3.1 material (wetted parts)

The Prosonic 92F integrates a loop-powered transmitter with an inline sensor in a rugged industrial design. It offers simple system integration, high accuracy and a competitive price, making it the ideal choice for the chemical and petrochemical industries.

Advantages
Safety design for the processing industries - numerous international explosion protection approvals
No pressure loss - full-bore design
High process transparency - diagnostic functions
Simple installation and low installation costs - loop-powered transmitter
Full compliance with industrial standards - IEC/ATEX/FM/CSA/TIIS/ NEPSI
Automatic data recovery for service purposes

Application areas
Choice of measuring principle not limited by pressure, density, temperature, conductivity and viscosity
Inline measurement, suitable for measuring homogeneous conductive and non-conductive liquids in the chemical and petrochemical industries
Instrument features
Full compliance with NACE MR0175 and MR0103
Nominal diameter: DN 25 ~ 300 (1 ~ 12")
Medium temperature: –40 ~ 200 °C (–40 ~ 392 °F)
Compact and remote versions available
Two-line backlit display with push-button operation
HART, PROFIBUS PA, FOUNDATION Fieldbus

 

Spare Parts & Accessories 38

38 spare parts · click to collapse
Order codeDescription
71026978amplifier boardDetails
71126042Amplified version 92F HART Ex V1.01.01Details
71028092amplifier boardDetails
71126044amplifier boardDetails
7106458492F AmplifierDetails
71126043amplifier boardDetails
71026979I/O boardDetails
71026980I/O boardDetails
71026981I/O boardDetails
71026982I/O boardDetails
71026984I/O boardDetails
71026985I/O boardDetails
71026986I/O boardDetails
71026987I/O boardDetails
50103472Display module (HART)Kit display 72/73/92F w. keyboard(HART)Details
50103473Display module (PA/FF)Kit display72/73/92F w/o keyboard(FF/PA)Details
71026991sensor terminal boardDetails
71026992sensor terminal boardDetails
50108141terminal blockKit Terminal Block 72/73/92FDetails
50103526cover with windowKit cover 72/73/92F with windowDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
1 models · click to collapse
All documents for this model
8 documents · click to expand
BA

Proline Prosonic Flow 92F FOUNDATION Fieldbus Operating Instructions English

FOUNDATION-Fieldbus Rev. 1310 96 pages
Preview
BA

Prosonic Flow 92F PROFIBUS PA Operating Instructions English

PROFIBUS-PA Rev. 1310 104 pages
Preview
BA

Proline Prosonic Flow 92F FOUNDATION Fieldbus Operating Instructions English

FOUNDATION-Fieldbus Rev. 0208 94 pages
Preview
BA

Proline Prosonic Flow 92F Operating Instructions English

114 pages
Preview
BA

Prosonic Flow 92F PROFIBUS PA Operating Instructions English

PROFIBUS-PA 100 pages
Preview
TI

技术资料 Proline Prosonic Flow 92F Chinese

Rev. 1310 20 pages
Preview
TI

Proline Prosonic Flow 92F Technical Information (SI units) English

Rev. 1310 20 pages
Preview
TI

Proline Prosonic Flow 92F Technical Information (SI units) English

Rev. 0209 20 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Ultrasonic flowmeter — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Ultrasonic flowmeter properly configured on the existing plant, with the aim of transit-time ultrasonic measurement of liquid or gas flow.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Ultrasonic flowmeter configuration has to involve checking straight runs, pipe internal condition and entrained gas.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant checking straight runs, pipe internal condition and entrained gas, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clamp-on versions avoid pipe work, minimising shutdown in revamps, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Ultrasonic flowmeter — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was transit-time ultrasonic measurement of liquid or gas flow.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking straight runs, pipe internal condition and entrained gas.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around checking straight runs, pipe internal condition and entrained gas, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clamp-on versions avoid pipe work, minimising shutdown in revamps, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Ultrasonic flowmeter — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Ultrasonic flowmeter, focusing on transit-time ultrasonic measurement of liquid or gas flow.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Ultrasonic flowmeter specification must therefore cover checking straight runs, pipe internal condition and entrained gas.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on checking straight runs, pipe internal condition and entrained gas, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clamp-on versions avoid pipe work, minimising shutdown in revamps, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Ultrasonic flowmeter — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Ultrasonic flowmeter; the focus is transit-time ultrasonic measurement of liquid or gas flow.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking straight runs, pipe internal condition and entrained gas.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on checking straight runs, pipe internal condition and entrained gas, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clamp-on versions avoid pipe work, minimising shutdown in revamps, which cut the workload on the site maintenance team.