Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CCM253 residual chlorine transmitter

CCM253 residual chlorine transmitter
Liquisys M CCM253
Configurable Models 3 models
E+H residual chlorine, chlorine dioxide, total chlorine transmitters, commonly used models: CCM253-EK0005 is connected to analog electrodes CCS51/CCS50/CCS120, single input, without PH compensation. CCM253-EP0005 is connected to analog electrodes CCS51/CCS50/CCS120+PH/ORP electrodes such as CPS11/CPS31/CPS12, with two inputs and pH compensation.
Compare

Disinfection

Measuring Principle Free chlorine
Application Drinking water, water, waste water, process, pool
Characteristic 4-wire transmitter for chlorine/chlordioxide in a field housing. Simple calibration with the "CAL"-button.
Design Overload protection, alarm relais, different controller functions (P(ID)), temperature display, 2-line display, current output galvanically separated.
Dimension 247mm x 170mm x 115mm
Input Chorine / Chlordioxide and pH/ORP Sensor.
Output / communication - Chlorine/Chlordioxid, pH, Temperature : 0/4-20mA- Profibus- Hart + 0/4-20mA

The Liquisys CCM253 is a standard free chlorine measuring transmitter and can also measure pH for compensation of the free chlorine measurement. Continuous plausibility, measuring process and sensor checks increase operational safety. Regardless of the choice from a wide range of hardware and software modules, such as relays and bus communication, it adapts fully to the measuring task. The transmitter can also be upgraded at any time; its simple menus and factory calibration make configuration and operation quick and convenient.

 

Advantages

Higher operational safety: continuous process check system, user-defined alarm settings, calibration plausibility check

Reliable chlorine and pH control: current input for flow monitoring with controller switch-off and feedforward control

Convenient operation and service: intuitive user interface, simple chlorine and pH calibration, manual contact control

Reduced maintenance workload: automatic cleaning function triggered by alarm and limit switches (with Chemoclean)

Suitable for various applications: multiple expansion options such as P(ID) controller, timer, etc., suitable for all processes

 

Areas of application

The Liquisys CCM253 transmitter can be used with various analog total chlorine, free chlorine, chlorine dioxide and pH sensors for the following measurement applications:

 

Water&wastewater

- Control and monitoring of the disinfection process

- Seawater desalination using membrane technology 

- Swimming pools

- Gas scrubbers

Food&beverage

- Disinfection of industrial process water

Power plants

- Cooling water disinfection

The Liquisys CCM253 uses the following communication protocols and interfaces:

 

0/4...20 mA

HART

PROFIBUS DP

PROFIBUS PA

Spare Parts & Accessories 31

31 spare parts · click to collapse
Order codeDescription
51500320Relay Output ModuleUpgrade of LIQUISYS-M basis version by 2 floating changeover contacts.Details
51511446Relay moduleUpgrade of LIQUISYS-M basis version by 2 floating changeover contacts.Details
51500321Relay Output Circuit BoardUpgrade of LIQUISYS-M basic version by 4 floating changeover contacts.Details
51511447Relay moduleDetails
51504304Relay Output ModuleUpgrade of LIQUISYS-M basic version by 2 contacts and current input 4-20mA.Details
51504305Relay Output ModuleUpgrade of LIQUISYS-M basic version by 4 contacts and current input 4-20mA.Details
51502467Kit CCM2x3 Main ModuleKit CCM2x3 Central module I1Details
51502497Kit CCM2x3 Main ModuleKit CCM2x3 central module I1 HARTDetails
51502468Kit CCM2x3 Main ModuleKit CCM2x3 Central module I2Details
51502496Kit CCM2x3 Main ModuleKit CCM2x3 central module I2 HARTDetails
51502495Kit CCM2x3 Main ModuleKit CCM2X3 central module Profibus PADetails
51502498Kit CCM2x3 Main ModuleKit CCM2X3 central module Profibus DPDetails
71134731Kit CCM2x3: Central Processing Unit (CPU)Details
71134732Relay moduleContent: 1x Relay module Profibus DP 2x Relay, 1x Current input DP connection qualified from H/W 2.10Details
51500317CXM2X3 AC Power SupplyKIT CXM2X3 power supply ACDetails
51500318CXM2X3 DC Power SupplyKIT CxM2x3 power supply DCDetails
51502466KIT MKC1 MEK TransmitterKIT MKC1 MEK transmitter Cl wo pH non ExDetails
51502465KIT MKC1 MEK TransmitterKit MKC1 MEK transmitter Cl+pH non ExDetails
51501068KIT CXM253 Instrument PanelKIT CXM253 housing coverDetails
71071446Kit CxM253: Front foil + 6 key liftersDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
3 models · click to collapse
Diagnostic codes(48 条)→
All documents for this model
12 documents · click to expand
BA

Liquisys M CLM223/253 操作手册 Chinese

Rev. 1515 116 pages
Preview
BA

Liquisys M CPM223/253 操作手册 Chinese

Rev. 1515 118 pages
Preview
BA

Liquisys M CCM223/253 操作手册 Chinese

Rev. 1515 124 pages
Preview
BA

Liquisys M COM223/253 操作手册 Chinese

Rev. 1515 118 pages
Preview
BA

Liquisys M CLM223/253 Operating Instructions English

Rev. 1515 122 pages
Preview
BA

Liquisys M CPM223/253 Operating Instructions English

Rev. 1515 124 pages
Preview
BA

Liquisys M CCM223/253 Operating Instructions English

Rev. 1515 132 pages
Preview
BA

Liquisys M COM223/253 Operating Instructions English

Rev. 1515 124 pages
Preview
BA

Operating Instructions Liquisys M CLM 223/253 English

Rev. 1311 108 pages
Preview
BA

Operating Instructions Liquisys M CPM 223/253 English

Rev. 1311 108 pages
Preview
BA

Operating Instructions Liquisys M CXM223/253 PROFIBUS English

Rev. 1311 40 pages
Preview
BA

operating Instructions Liquisys M CCM 223 / 253 English

Rev. 1311 116 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · sterilize — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is sterilize; the focus is monitoring and controlling disinfectant dosing and efficacy.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with matching monitoring points to the disinfection route (chlorine, UV, ozone).

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on matching monitoring points to the disinfection route (chlorine, UV, ozone), and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means on-demand dosing, lowering both by-products and cost, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · sterilize — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on sterilize and the core task is monitoring and controlling disinfectant dosing and efficacy.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So sterilize cannot be specified generically — it calls for matching monitoring points to the disinfection route (chlorine, UV, ozone).

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves matching monitoring points to the disinfection route (chlorine, UV, ozone), with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is on-demand dosing, lowering both by-products and cost.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · sterilize — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted sterilize properly configured on the existing plant, with the aim of monitoring and controlling disinfectant dosing and efficacy.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the sterilize configuration has to involve matching monitoring points to the disinfection route (chlorine, UV, ozone).

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant matching monitoring points to the disinfection route (chlorine, UV, ozone), checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is on-demand dosing, lowering both by-products and cost, and the readings are now used for process tuning.

Power & Energy

Power & Energy · sterilize — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was monitoring and controlling disinfectant dosing and efficacy.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means matching monitoring points to the disinfection route (chlorine, UV, ozone).

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around matching monitoring points to the disinfection route (chlorine, UV, ozone), with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — on-demand dosing, lowering both by-products and cost, with routine maintenance falling noticeably.