Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CCS51D residual chlorine sensor

CCS51D residual chlorine sensor

余氯传感器

Configurable Models 6 models
Memosens sensors are suitable for drinking water, pool water, process water, and utilities in various industries, An alternative model to CCS142D, Ayi Technology has stock of CCS51D, with a range of 0.05-20mg for CCS51D-AA11BF; CCS51D-AA11AD has a range of 0.01-5mg
Compare

Disinfection

Measuring Principle
Application Ensuring reliable disinfection in drinking water
Process water
Dosing disinfectant efficiently in pool water
Detect the absence or presence of free chlorine in Utilities
Guarantee food safety and provide hygienic packaging and bottling
Characteristic Amperometric measurement of dissolved free chlorine
Measuring range Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
High: 0 to 200 mg/l HOCl
Measuring method Closed, membrane covered measuring cell
Reduction of free chlorine at the cathode
Design Closed amperometric 2-electrode measuring cell with PVDF membrane
Material Sensor shaft: POM
Membrane: PVDF
Membrane cap: PVDF
Sealing ring: FKM
Dimension Diameter: 25 mm (0.98 inch)
Length: 161 mm (6.34 inch)
Process temperature 0 to 55 °C (32 to 130 °F), non-freezing
Process pressure Max. 1 bar (max. 14.5 psi)
Temperature sensor 10k NTC integrated (Memosens)
Connection Inductive, digital connection head with Memosens

The Memosens CCS51D free chlorine sensor is robust and requires low maintenance. The sensor performs high-precision measurement with high long-term stability in drinking water, pool water and process water; it reliably monitors the disinfection process even at low flow rates. The short response time of the free chlorine sensor ensures efficient process control and process safety. The CCS51D uses Memosens digital technology for the highest process and data integrity, and is easy to operate.

Benefits
A suitable sensor for every application: from trace measurement up to a free chlorine concentration of no more than 200 mg/l.
Short response time (t90 < 25 seconds) with high-precision indication of process status, enabling prompt action in response to process changes and efficient process control.
Greater process safety: accurate and long-term stable measurement enables permanent process monitoring, with flexible on-demand adjustment of the disinfectant concentration.
The fluorescence-based sensor requires low maintenance and, compared with colorimetric measuring systems, significantly reduces the operating costs of the measuring point.
Fast and convenient sensor replacement for longer uptime: laboratory pre-calibrated sensor, plug-and-play on site.
Used together with the Liquiline multiparameter transmitter, it can simultaneously measure other relevant water analysis parameters such as pH and ORP.

Applications
The Memosens CCS51D free chlorine sensor meets the requirements of skid manufacturers and end users. It reliably measures:
Drinking water: ensures reliable disinfection
Food: ensures food safety and hygienic bagged and bottled products
Utilities: detects the presence of free chlorine
Pool water: efficient dosing of disinfectant

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

   

Measurement principle video

Source: Endress+Hauserpublic information from the website

Model Name
CCS51D-AA11BF 余氯传感器
CCS51D-AA11AD 余氯传感器
CCS51D-AA11AD+NC 余氯传感器
CCS51D-AA11CJ+NC 余氯传感器
CCS51D-AA11BF+NC 余氯传感器
CCS51D-AA11AD+NCZ1 余氯传感器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Disinfection Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Disinfection Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Disinfection Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Disinfection Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;